Experimental investigation of an integrated absorption- solid desiccant air conditioning system

被引:17
作者
Ali, Muzaffar [1 ]
Habib, Muhammad Farhan [1 ]
Sheikh, Nadeem Ahmed [2 ]
Akhter, Javed [3 ]
Gilani, Syed Ihtsham ul Haq [4 ]
机构
[1] Univ Engn & Technol, Mech Engn Dept, Taxila, Pakistan
[2] Int Islamic Univ, Fac Engn & Technol, Mech Engn Dept, Islamabad, Pakistan
[3] Univ Chakwal, Dept Mechatron Engn, Chakwal, Punjab, Pakistan
[4] Univ Teknol PETRONAS, Mech Engn Dept, Seri Iskandar 32610, Perak, Malaysia
关键词
Integrated system; Solid desiccant; Dehumidification; Thermal load; Absorption system; COOLING SYSTEM; SOLAR-ENERGY; HYBRID; PERFORMANCE; HOT; REFRIGERATION;
D O I
10.1016/j.applthermaleng.2021.117912
中图分类号
O414.1 [热力学];
学科分类号
摘要
Separate handling of sensible and latent components of building loads can be an energy efficient approach compared to simultaneous management of both. This paper presents a detailed experimental analysis of an energy efficient air conditioning system using solid desiccant integrated with absorption system for separate building thermal load handling. The experimental system consists of silica-gel based solid desiccant for latent load handling, whereas the gas fired air-cooled NH3-H2O absorption chiller is used to handle sensible load of the space. A chilled water-cooling coil heat exchanger is installed on the process side of desiccant cooling system to integrate it with the absorption chiller. The performance of integrated absorption- solid desiccant system is compared with a standalone conventional desiccant air conditioning system with a direct evaporative cooler considering it as baseline system under wide range of operating conditions including air temperature, air humidity, and regeneration temperature. The comparative analysis is performed in terms of supply air temperature, cooling capacity, and coefficient of performance. The experimental results exhibit that supply air temperature of the integrated system is 15.2 degrees C compared to 24.6 degrees C achieved by conventional desiccant system. Moreover, COPth of the integrated system is also 50-55% higher than its counterpart and it is almost comparable with double-effect absorption chiller. It is concluded that the integrated system using separate load management approach is more efficient for HVAC applications.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Study on a Novel Hybrid Desiccant Dehumidification and Air Conditioning System
    Sumathy, K.
    Yong, Li
    Dai, Y. J.
    Wang, R. Z.
    SUSTAINABILITY IN ENERGY AND BUILDINGS, 2009, : 413 - +
  • [42] Control strategies for a liquid desiccant air-conditioning system
    Ge, Gaoming
    Xiao, Fu
    Niu, Xiaofeng
    ENERGY AND BUILDINGS, 2011, 43 (06) : 1499 - 1507
  • [43] Experimental investigation of solar driven desiccant air conditioning system based on silica gel coated heat exchanger
    Kumar, Amit
    Yadav, Auadhesh
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 69 : 51 - 63
  • [44] Experimental investigation of precooling desiccant-wheel air-conditioning system in a high-temperature and high-humidity environment
    Chen, L.
    Chen, S. H.
    Liu, L.
    Zhang, B.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 95 : 83 - 92
  • [45] Experimental investigation on integrated liquid desiccant - Indirect evaporative air cooling system utilizing the Maisotesenko - Cycle
    Gao, W. Z.
    Cheng, Y. P.
    Jiang, A. G.
    Liu, T.
    Anderson, Keith
    APPLIED THERMAL ENGINEERING, 2015, 88 : 288 - 296
  • [46] Solar energy assisted desiccant air conditioning system with PCM as a thermal storage medium
    Kabeel, A. E.
    Abdelgaied, Mohamed
    RENEWABLE ENERGY, 2018, 122 : 632 - 642
  • [47] A new solar coupling regeneration method for liquid desiccant air-conditioning system
    Cheng Qing
    Zhang Xiao-song
    Xu Yao
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2014, 21 (08) : 3214 - 3224
  • [48] Experimental analysis and regression prediction of desiccant wheel behavior in high temperature heat pump and desiccant wheel air-conditioning system
    Sheng, Ying
    Zhang, Yufeng
    Sun, Yuexia
    Fang, Lei
    Nie, Jinzhe
    Ma, Lijun
    ENERGY AND BUILDINGS, 2014, 80 : 358 - 365
  • [49] Thermo-economic performance of a solar membrane liquid desiccant air conditioning system
    Abdel-Salam, Ahmed H.
    Ge, Gaoming
    Simonson, Carey J.
    SOLAR ENERGY, 2014, 102 : 56 - 73
  • [50] Experimental investigation of a ground-coupled air conditioning system with desiccant assisted enthalpy recovery during winter mode
    Niemann, Peter
    Schmitz, Gerhard
    APPLIED THERMAL ENGINEERING, 2019, 160