A Theoretical Analysis of Thixotropic Parameter's Influence on Blood Flow Through Constriction

被引:1
作者
Shahid, Nazish [1 ,2 ]
机构
[1] Forman Christian Coll, Dept Math, Lahore 54600, Pakistan
[2] Princeton Univ, Dept Mech & Aerosp Engn, Princeton, NJ 08540 USA
关键词
Thixotropy; Blood flow; Time dependence; Constricted channel; Axial velocity; Yield stress; NON-NEWTONIAN FLUID; PULSATILE FLOW; CONSTITUTIVE MODEL; TAPERED ARTERIES; UNSTEADY-FLOW; POROUS-MEDIUM; RHEOLOGY; HEMATOCRIT; STENOSIS;
D O I
10.1007/s13369-018-3603-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study has been prepared to investigate the changes in the dynamics of blood flow through a stenosed tapered artery owing to a change in structural parameter of thixotropic model. Following the time evolution range of this parameter as [0,1] for transient shear flows, the effects of on axial velocity, shear stress, flow rate and resistance to flow have been probed. Analytical expressions of axial velocity and shear stress have been obtained along with numerical computation of pressure gradient by means of continuity equation. The evolution of system with respect to time, t has been investigated in order to study the changes in dynamics of flow at certain times. A comparison of axial velocity profiles for some values of has been made to obtain profiles for Power law fluid and Newtonian fluid model. The inclination of velocity profiles for 0.51 towards experimental velocity profiles has been suggested by means of comparison with available results in history. This analysis has also been prepared as a foundational step of construction of an artificial channel with constriction and of adaptation of most suitable modelling of blood flow such that the findings of the parameter and its influence on flow can be incorporated experimentally for induction of decreased wall stress.
引用
收藏
页码:1501 / 1514
页数:14
相关论文
共 56 条
  • [1] A new generalized Oldroyd-B model for blood flow in complex geometries
    Anand, M.
    Kwack, J.
    Masud, A.
    [J]. INTERNATIONAL JOURNAL OF ENGINEERING SCIENCE, 2013, 72 : 78 - 88
  • [2] Anand M., 2004, INT J CARDIOVASCULAR, V4, P59
  • [3] Modeling of human blood rheology in transient shear flows
    Apostolidis, Alex J.
    Armstrong, Matthew J.
    Beris, Antony N.
    [J]. JOURNAL OF RHEOLOGY, 2015, 59 (01) : 275 - 298
  • [4] Modeling of the blood rheology in steady-state shear flows
    Apostolidis, Alex J.
    Beris, Antony N.
    [J]. JOURNAL OF RHEOLOGY, 2014, 58 (03) : 607 - 633
  • [5] Bird RB, 1977, DYNAMICS POLYM 1 FLU
  • [6] BUREAU M, 1980, BIORHEOLOGY, V17, P191
  • [7] RHEOLOGY OF ARTIFICIALLY MODIFIED SAMPLES OF HUMAN-BLOOD IN TRANSIENT FLOW
    BUREAU, M
    HEALY, JC
    BOURGOIN, D
    JOLY, M
    [J]. RHEOLOGICA ACTA, 1979, 18 (06) : 756 - 768
  • [8] HEMODYNAMICS OF AN ARTERY WITH MILD STENOSIS
    CAVALCANTI, S
    [J]. JOURNAL OF BIOMECHANICS, 1995, 28 (04) : 387 - 399
  • [9] EFFECTS OF STENOSIS ON THE FLOW-BEHAVIOR OF BLOOD IN AN ARTERY
    CHAKRAVARTY, S
    [J]. INTERNATIONAL JOURNAL OF ENGINEERING SCIENCE, 1987, 25 (08) : 1003 - 1016
  • [10] Two-dimensional blood flow through tapered arteries under stenotic conditions
    Chakravarty, S
    Mandal, PK
    [J]. INTERNATIONAL JOURNAL OF NON-LINEAR MECHANICS, 2000, 35 (05) : 779 - 793