Biomechanical Effects of Loop Thickness in ACL Graft: A Simulation Study

被引:4
作者
Bae, Tae Soo [1 ]
Kwak, Dai-Soon [2 ]
机构
[1] Jungwon Univ, Dept Biomed Engn, 85 Munmu Ro, Goesan Gun 28024, Chungcheongbuk, South Korea
[2] Catholic Univ Korea, Coll Med, Catholic Inst Appl Anat, 222 Banpo Daero, Seoul 06591, South Korea
基金
新加坡国家研究基金会;
关键词
Anterior cruciate ligament reconstruction; Button-loop cortical suspension device; Contact stress; Knee stability; CRUCIATE LIGAMENT RECONSTRUCTION; CORTICAL SUSPENSION DEVICES; FEMORAL FIXATION DEVICE; HUMAN KNEE; TISSUE;
D O I
10.1007/s12541-021-00609-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A cortical suspension device that combines a loop and a button is used widely for anterior cruciate ligament reconstruction surgery. Although various biomechanical studies using these devices have been conducted, relatively few have explored the biomechanics of the wire-graft contact region depending on the thickness of the loop wire. In this study, the effects of loop thickness on the graft contact region were tested, and the recommended loop thickness was analyzed by constructing a simulation model to reflect this effect. Five groups of specimens were prepared by combining 50 porcine tendons and loop wires with thicknesses ranging from 1.5 to 3.5 mm at 0.5-mm intervals, and the elongation and hardness changes in the contact region were measured and recorded. In addition, the maximum stress on the graft was analyzed by a computer simulation model based on the biomechanical test results. Statistically significant elongation and contact hardening occurred in the thin loop wires <= 3.0 mm. In addition, larger amounts of contact stress were found for loops with a thickness <= 2.5 mm. In consideration of elongation and contact stress, loops with a thickness >= 3.0 mm are recommended for ACL reconstruction.
引用
收藏
页码:205 / 211
页数:7
相关论文
共 21 条
[1]   Treatment of anterior cruciate ligament injuries, part I [J].
Beynnon, BD ;
Johnson, RJ ;
Abate, JA ;
Fleming, BC ;
Nichols, CE .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (10) :1579-1602
[2]   Microstructural and Mechanical Properties of Grafts Commonly Used for Cruciate Ligament Reconstruction [J].
Castile, Ryan M. ;
Jenkins, Matthew J. ;
Lake, Spencer P. ;
Brophy, Robert H. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2020, 102 (22) :1948-1955
[3]   Does ACL Reconstruction Alter Natural History? A Systematic Literature Review of Long-Term Outcomes [J].
Chalmers, Peter N. ;
Mall, Nathan A. ;
Moric, Mario ;
Sherman, Seth L. ;
Paletta, George P. ;
Cole, Brian J. ;
Bach, Bernard R., Jr. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (04) :292-300
[4]   Sex-based differences in the tensile properties of the human anterior cruciate ligament [J].
Chandrashekar, Naveen ;
Mansouri, Hossein ;
Slauterbeck, James ;
Hashemi, Javad .
JOURNAL OF BIOMECHANICS, 2006, 39 (16) :2943-2950
[5]   A Comparative Biomechanical Study of Femoral Cortical Suspension Devices for Soft-Tissue Anterior Cruciate Ligament Reconstruction: Adjustable-Length Loop Versus Fixed-Length Loop [J].
Chang, Moon Jong ;
Bae, Tae Soo ;
Moon, Young-Wan ;
Ahn, Jin Hwan ;
Wang, Joon Ho .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (02) :566-572
[6]   A new femoral fixation device for anterior cruciate ligament reconstruction using the outside-in technique and hamstring tendon graft: A comparison between two devices in cadaveric human knee models [J].
Chong, Suri ;
Kwak, Dai-Soon ;
Balasubramanian, Dhanasekaraprabu ;
Song, Young Dong ;
Na, Young Gon ;
Kim, Tae Kyun .
KNEE, 2017, 24 (05) :925-932
[7]   Evaluation of biomechanical properties: are porcine flexor tendons and bovine extensor tendons eligible surrogates for human tendons in in vitro studies? [J].
Domnick, C. ;
Wieskoetter, B. ;
Raschke, M. J. ;
Schulze, M. ;
Kronenberg, D. ;
Wefelmeier, M. ;
Langer, M. F. ;
Herbort, M. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (10) :1465-1471
[8]  
Fung Y.C., 1993, Biomechanics, DOI DOI 10.1007/978-1-4757-2257-4
[9]  
Johnson Donald H, 2003, Arthroscopy, V19, P424
[10]   A Biomechanical Comparison of Femoral Cortical Suspension Devices for Soft Tissue Anterior Cruciate Ligament Reconstruction Under High Loads [J].
Johnson, Jared S. ;
Smith, Sean D. ;
LaPrade, Christopher M. ;
Turnbull, Travis Lee ;
LaPrade, Robert F. ;
Wijdicks, Coen A. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2015, 43 (01) :154-160