Radiation Doses for Different Approaches of Fluoroscopy-Guided Epidural Injections: An Observational Clinical Study

被引:0
作者
Sacaklidir, Rekib [1 ]
Ozturk, Ekim Can [1 ]
Sencan, Savas [1 ]
Gunduz, Osman Hakan [1 ]
机构
[1] Marmara Univ, Dept Phys Med & Rehabil, Div Pain Med, Istanbul, Turkey
关键词
Spine; epidural injections; radiation; radiation exposure; fluoroscopy; prevention; device safety; MANAGING CHRONIC PAIN; MEDICARE POPULATION; STEROID INJECTIONS; DOUBLE-BLIND; EXPOSURE; MANAGEMENT; GROWTH; SAFETY;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Although fluoroscopy-guided interventional therapies have declined in recent years, radiation exposure remains a critical issue for both patients and medical staff. Radiation exposure varies according to the physicians' experience, procedure time, patients' body mass index (BMI), imaging techniques, and the type of procedure performed. Objective: The purpose of this study is to report procedure times and calculate the radiation doses for 4 different approaches of fluoroscopy-guided epidural injections per procedure and BMI to provide radiations doses for potential use in future dose reduction strategies. Study Design: Retrospective, observational study. Setting: A university hospital, pain management center. Methods: A retrospective evaluation was performed of patients who received epidural steroid injections between January 2015 and December 2020 in a university hospital interventional pain management center. This observational study was conducted with patients aged >= 18 who underwent 3,711 epidural injections including cervical interlaminar, lumbar interlaminar, lumbar transforaminal, and caudal approaches. If more than one level or bilateral injections were performed, total dose and times were divided by the number of sites injected to attain procedure time and mean dose per injection. Provided doses for each patient were also divided by patients' BMI to obtain dose per BMI. Results: The highest radiation dose per procedure was found in caudal epidural injection with 0.218 mGy.m(2), and the lowest dose was found in cervical interlaminar epidural injection with 0.057 mGy.m(2). The radiation dose per procedure was 0.123 mGy.m(2) for lumbar transforaminal and 0.191 mGy.m(2) for lumbar interlaminar epidural injection. The shortest procedure time was determined in transforaminal (37.3 seconds) injections, and the longest was in lumbar interlaminar (46.7 seconds) injections. Caudal epidural injection also had the highest radiation dose per BMI which was 0.00749, and cervical interlaminar epidural injection had the lowest radiation dose per BMI, which was 0.00214. Limitations: Firstly, injections were performed by first-or second-year fellows in pain medicine. Moreover, patient-related factors (previous surgery, scoliosis, etc.) affecting radiation exposure were ignored. Conclusions: Radiation dose levels and procedure times of 4 approaches of epidural injections were obtained from 3,711 procedures performed in a university hospital pain medicine clinic. BMI of patients was taken into account with the dose levels of injections given per BMI. Multicenter research with standardized techniques will assure more reliable reference levels, which will guide pain physicians to self-assess their own levels of radiation exposure.
引用
收藏
页码:E67 / E72
页数:6
相关论文
共 26 条
  • [1] Comparison of treatment outcomes in lumbar disc herniation patients treated with epidural steroid injections: interlaminar versus transforaminal approach
    Bensler, Susanne
    Walde, Melissa
    Fischer, Michael A.
    Pfirrmann, Christian W. A.
    Peterson, Cynthia K.
    Sutter, Reto
    [J]. ACTA RADIOLOGICA, 2020, 61 (03) : 361 - 369
  • [2] Feasibility and safety of ultrasound-guided caudal epidural glucocorticoid injections
    Blanchais, Anne
    Le Goff, Benoit
    Guillot, Pascale
    Berthelot, Jean-Marie
    Glemarec, Joelle
    Maugars, Yves
    [J]. JOINT BONE SPINE, 2010, 77 (05) : 440 - 444
  • [3] Braun E, 2018, PAIN PHYSICIAN, V21, P53
  • [4] Comparison of the Oblique Interlaminar and Transforaminal Lumbar Epidural Steroid Injections for Treatment of Low Back and Lumbosacral Radicular Pain
    Choi, Eun-Ji
    Park, Soon Ji
    Yoo, Yeong-Min
    Yoon, Ji-Uk
    Shin, Sang-Wook
    Byeon, Gyeong-Jo
    [J]. JOURNAL OF PAIN RESEARCH, 2021, 14 : 407 - 414
  • [5] Factors Related to Radiation Exposure during Lumbar Spine Intervention
    Choi, Moon Hyung
    Choi, Byung Gil
    Jung, Seung Eun
    Byun, Jae Young
    [J]. JOURNAL OF KOREAN MEDICAL SCIENCE, 2016, 31 : S55 - S58
  • [6] Cohen SL, 2019, PAIN PHYSICIAN, V22, pE119
  • [7] The Effect of Body Mass Index on Fluoroscopic Time and Radiation Dose During Sacroiliac Joint Injections
    Cushman, Daniel
    Flis, Alexandra
    Jensen, Ben
    McCormick, Zachary
    [J]. PM&R, 2016, 8 (08) : 767 - 772
  • [8] Examining the association of body mass index and the depth of epidural space, radiation dose exposure and fluoroscopic screening time during transforaminal nerve block injection: a retrospective cohort study
    Galbraith, Adam S.
    Wallace, Emma
    Devitt, Aiden
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2019, 188 (01) : 295 - 302
  • [9] Prevalence and Correlates of Worry About the Health Harms of Medical Imaging Radiation in the General Population
    Hay, Jennifer L.
    Gold, Geoffrey S.
    Baser, Raymond E.
    Hricak, Hedvig
    Dauer, Lawrence T.
    [J]. JOURNAL OF PRIMARY CARE AND COMMUNITY HEALTH, 2016, 7 (04) : 219 - 225
  • [10] Radiation Exposure for Fluoroscopy-guided Lumbosacral Epidural Steroid Injections Comparison of the Transforaminal and Caudal Approaches
    Kim, Seon-Jeong
    Lee, Min Hee
    Lee, Sheen-Woo
    Chung, Hye Won
    Lee, Sang Hoon
    Shin, Myung Jin
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2014, 27 (01): : E37 - E40