Comparison of intraocular pressure measurements between the Tono-Pen XL® and Perkins® applanation tonometers in dogs and cats

被引:25
|
作者
Andrade, Silvia Franco [1 ]
Palozzi, Rodrigo Jesus [2 ]
Giuffrida, Rogerio [3 ]
de Campos, Renata Juliane [3 ]
Santos, Gabriela de Campos [3 ]
Fukui, Rosimery Missuzu [4 ]
机构
[1] Univ Oeste Paulista UNOESTE, Dept Small Anim Med, Vet Hosp, BR-19001970 Presidente Prudente, SP, Brazil
[2] Univ Ctr Maringa CESUMAR, Fac Vet Med, Maringa, Parana, Brazil
[3] Univ Oeste Paulista, Fac Vet Med, Presidente Prudente, SP, Brazil
[4] Univ Oeste Paulista UNOESTE, Vet Hosp Resident, Sao Paulo, SP, Brazil
关键词
applanation tonometer; cats; dogs; intraocular pressure; Perkins tonometer; Tono-Pen XL tonometer; REBOUND TONOMETER; HAND-HELD; RABBITS; CALIBRATION; HORSES; XL;
D O I
10.1111/j.1463-5224.2011.00926.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To compare the accuracy between two applanation tonometers, Tono-Pen XL (R) and Perkins (R), in ophthalmoscopically normal dogs and cats. Animals Both eyes of 25 conscious and healthy dogs and cats were evaluated. Both eyes of five dogs and cats immediately after sacrifice were used as controls for the postmortem study. Procedure In conscious animals, the tonometry was performed with topical anesthesia using 0.5% proxymetacaine eye drops for both tonometers and 1% fluorescein eye drops for the Perkins tonometer. Readings of intraocular pressure (IOP) in the postmortem study were taken using manometry and tonometry by Tono-Pen XL (R) and Perkins (R). Results The correlation coefficient (r(2)) in dogs between manometry and applanation tonometers Tono-Pen XL (R) and Perkins (R) were, respectively, 0.896 and 0.981 and in cats were 0.905 and 0.988. The mean IOP values in conscious dogs with Tono-Pen XL (R) and Perkins (R) were, respectively, 17.5 +/- 3.7 mmHg (10.0-25.0 mmHg) and 15.3 +/- 2.1 mmHg (12.0-19.8 mmHg) and in conscious cats were 16.8 +/- 3.6 mmHg (10.5-24.5 mmHg) and 15.5 +/- 1.3 mmHg (13.0-18.5 mmHg). Conclusion There was a strong correlation between the IOP values obtained by direct ocular manometry and the Tono-Pen XL (R) and Perkins (R) tonometers in dogs and cats. There was no statistically significant difference between the mean IOP obtained with both tonometers in conscious animals, there was, however, a difference between the minimum and mainly in the maximum values that were on average 5-6 mmHg higher with Tono-Pen XL (R) than those measured with Perkins (R), which justifies a table of normal values differentiated for each tonometer.
引用
收藏
页码:14 / 20
页数:7
相关论文
共 50 条
  • [1] Intraocular pressure measurements with the Tono-Pen XL® and Perkins® applanation tonometers in horses and cattle
    Andrade, Silvia Franco
    Palozzi, Rodrigo de Jesus
    Rolim, Rodrigo Duarte
    Cecilio Junqueira, Jose Ricardo
    do Valle, Heloisa Ferreira
    da Silva, Marcelo Kurak
    Maia, Marcelo Augusto
    Zampiere, Rodrigo Augusto
    CIENCIA RURAL, 2013, 43 (05): : 865 - 870
  • [2] Measurements of Intraocular Pressure with Tono-Pen and Goldmann Applanation Tonometers in Subjects with Systemic Illness
    Hsu, Sheng-Yao
    Lin, Shu-Fang
    Hsu, Ai-Hsi
    TZU CHI MEDICAL JOURNAL, 2007, 19 (04): : 241 - 244
  • [3] Comparison of simultaneous readings of intraocular pressure in rabbits using Perkins handheld, Tono-Pen XL, and TonoVet tonometers
    Kalesnykas, Giedrius
    Uusitalo, Hannu
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (05) : 761 - 762
  • [4] Comparison of simultaneous readings of intraocular pressure in rabbits using Perkins handheld, Tono-Pen XL, and TonoVet tonometers
    Giedrius Kalesnykas
    Hannu Uusitalo
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 761 - 762
  • [5] Comparison of Tono-Pen and Goldmann applanation tonometers for measurement of intraocular pressure in healthy children
    Bradfield, Yasmin S.
    Kaminski, Brett M.
    Repka, Michael X.
    Melia, Michele
    JOURNAL OF AAPOS, 2012, 16 (03): : 242 - 248
  • [6] Comparison of Scleral Tono-Pen Intraocular Pressure Measurements with Goldmann Applanation Tonometry
    Badakere, Swathi Vallabh
    Choudhari, Nikhil S.
    Rao, Harsha L.
    Chary, C. Raghava
    Garudadri, Chandra Sekhar
    Senthil, Sirisha
    OPTOMETRY AND VISION SCIENCE, 2018, 95 (02) : 129 - 135
  • [7] CLINICAL COMPARISON OF THE PROTON AND TONO-PEN TONOMETERS WITH THE GOLDMANN APPLANATION TONOMETER
    MIDELFART, A
    WIGERS, A
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1994, 78 (12) : 895 - 898
  • [8] Comparison of Tono-Pen AVIA Intraocular Pressure Measurements Performed at Limbus With Central Corneal Tono-Pen AVIA Intraocular Pressure
    Sharma, Reetika
    Majumdar, Saptorishi
    Sobti, Amit
    Arora, Tarun
    Agarwal, Tushar
    Dada, Tanuj
    CORNEA, 2013, 32 (07) : 943 - 946
  • [9] A comparison of Icare PRO and Tono-Pen XL tonometers in anesthetized children
    McKee, Elliot C.
    Ely, Amanda L.
    Duncan, Jared E.
    Dosunmu, Eniolami O.
    Freedman, Sharon F.
    JOURNAL OF AAPOS, 2015, 19 (04): : 332 - 337
  • [10] The relationship between intraocular pressure and central corneal thickness: A comparison between the Tono-Pen and Goldmann applanation
    Zhao, F
    Thomas, S
    Enzenauer, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S515 - S515