Comparison of Three-Dimensional Proximal Isovelocity Surface Area to Cardiac Magnetic Resonance Imaging for Quantifying Mitral Regurgitation

被引:24
作者
Brugger, Nicolas [1 ]
Wustmann, Kerstin [1 ]
Huerzeler, Michael [1 ]
Wahl, Andreas [1 ]
de Marchi, Stefano F. [1 ]
Steck, Helene [1 ]
Zuercher, Fabian [1 ]
Seiler, Christian [1 ]
机构
[1] Univ Hosp Bern, Dept Cardiol, CH-3010 Bern, Switzerland
关键词
COLOR DOPPLER-ECHOCARDIOGRAPHY; FLOW CONVERGENCE; IN-VITRO; QUANTIFICATION; VALIDATION; RECOMMENDATIONS;
D O I
10.1016/j.amjcard.2015.01.550
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of our study was to evaluate 3-dimensional (3D) color Doppler proximal isovelocity surface area (PISA) as a tool for quantitative assessment of mitral regurgitation (MR) against in vitro and in vivo reference methods. A customized 3D PISA software was validated in vitro against a flowmeter MR phantom. Sixty consecutive patients, with >= mild MR of any cause, were recruited and the regurgitant volume (RVol) was measured by 2D PISA, 3D peak PISA, and 3D integrated PISA, using transthoracic (TTE) and transesophageal echocardiography (TEE). Cardiac magnetic resonance imaging (CMR) was used as reference method. Flowmeter RVol was associated with 3D integrated PISA as follows: y = 0.64x + 4.7, r(2) = 0.97, p < 0.0001 for TEE and y = 0.88x + 4.07, r(2) = 0.96, p < 0.0001 for TTE. The bias and limit of agreement in the Bland-Altman analysis were 6.8 ml [-3.5 to 17.1] for TEE and -0.059 ml [-6.2 to 6.1] for TTE. In vivo, TEE-derived 3D integrated PISA was the most accurate method for MR quantification compared to CMR: r(2) = 0.76, y = 0.95x - 3.95, p < 0.0001; 5.1 ml (-14.7 to 26.5). It was superior to TEE 3D peak PISA (r(2) = 0.67, y = 1.00x + 6.20, p < 0.0001; -6.3 ml [-33.4 to 21.0]), TEE 2D PISA (r(2) = 0.54,y = 0.76x + 0.18, p < 0.0001; 8.4 ml [-20.4 to 37.2]), and TTE-derived measurements. It was also most accurate by receiver operating characteristic analysis (area under the curve 0.99) for the detection of severe MR, RVol cutoff = 48 ml, sensibility 100%, and specificity 96%. RVol and the cutoff to define severe MR were underestimated using the most accurate method. In conclusion, quantitative 3D color Doppler echocardiography of the PISA permits a more accurate MR assessment than conventional techniques and, consequently, should enable an optimized management of patients suffering from MR. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1130 / 1136
页数:7
相关论文
共 50 条
  • [41] FEASIBILITY OF ULTRASOUND-BASED COMPUTATIONAL FLUID DYNAMICS AS A MITRAL VALVE REGURGITATION QUANTIFICATION TECHNIQUE: COMPARISON WITH 2-D AND 3-D PROXIMAL ISOVELOCITY SURFACE AREA-BASED METHODS
    Jamil, Muhammad
    Ahmad, Omar
    Poh, Kian Keong
    Yap, Choon Hwai
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (07) : 1314 - 1330
  • [42] Accuracy of Three-Dimensional Versus Two-Dimensional Echocardiography for Quantification of Aortic Regurgitation and Validation by Three-Dimensional Three-Directional Velocity-Encoded Magnetic Resonance Imaging
    Ewe, See Hooi
    Delgado, Victoria
    van der Geest, Rob
    Westenberg, Jos J. M.
    Haeck, Marlieke L. A.
    Witkowski, Tomasz G.
    Auger, Dominique
    Marsan, Nina Ajmone
    Holman, Eduard R.
    de Roos, Albert
    Schalij, Martin J.
    Bax, Jeroen J.
    Sieders, Allard
    Siebelink, Hans-Marc J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (04) : 560 - 566
  • [43] Quantitative assessment of primary mitral regurgitation using left ventricular volumes obtained with new automated three-dimensional transthoracic echocardiographic software: A comparison with 3-Tesla cardiac magnetic resonance
    Levy, Franck
    Marechaux, Sylvestre
    Iacuzio, Laura
    Schouver, Elie Dan
    Castel, Anne Laure
    Toledano, Manuel
    Rusek, Stephane
    Dor, Vincent
    Tribouilloy, Christophe
    Dreyfus, Gilles
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2018, 111 (8-9) : 507 - 517
  • [44] Assessment of right ventricular volumes in hypoplastic left heart syndrome by real-time three-dimensional echocardiography: comparison with cardiac magnetic resonance imaging
    Bell, Aaron
    Rawlins, Debbie
    Bellsham-Revell, Hannah
    Miller, Owen
    Razavi, Reza
    Simpson, John
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (03) : 257 - 266
  • [45] Direct Measurement of Proximal Isovelocity Surface Area by Real-Time Three-Dimensional Color Doppler for Quantitation of Aortic Regurgitant Volume: An In Vitro Validation
    Pirat, Bahar
    Little, Stephen H.
    Igo, Stephen R.
    McCulloch, Marti
    Nose, Yukihiko
    Hartley, Craig J.
    Zoghbi, William A.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (03) : 306 - 313
  • [46] Accuracy and sensitivity of three-dimensional echocardiography to detect changes in right ventricular volumes: comparison study with cardiac magnetic resonance
    Myhr, K. A.
    Kristensen, C. B.
    Pedersen, F. H. G.
    Hassager, C.
    Vejlstrup, N.
    Mattu, R.
    Pecini, R.
    Mogelvang, R.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (02) : 493 - 502
  • [47] Clinical Implications of Three-Dimensional Real-Time Color Doppler Transthoracic Echocardiography in Quantifying Mitral Regurgitation: A Comparison with Conventional Two-Dimensional Methods
    Heo, Ran
    Son, Jang-Won
    Hartaigh, Briain O.
    Chang, Hyuk-Jae
    Kim, Young-Jin
    Datta, Saurabh
    Cho, In-Jeong
    Shim, Chi Young
    Hong, Geu-Ru
    Ha, Jong-Won
    Chung, Namsik
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (04) : 393 - U158
  • [48] Geometric Errors of the Pulsed-Wave Doppler Flow Method in Quantifying Degenerative Mitral Valve Regurgitation: A Three-Dimensional Echocardiography Study
    Ren, Ben
    de Groot-de Laat, Lotte E.
    McGhie, Jacky
    Vletter, Wim B.
    ten Cate, Folkert J.
    Geleijnse, Marcel L.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (03) : 261 - 269
  • [49] Comprehensive Assessment of Right Ventricular Function by Three-Dimensional Speckle-Tracking Echocardiography : Comparisons with Cardiac Magnetic Resonance Imaging
    Li, Yuman
    Zhang, Li
    Gao, Ying
    Wan, Xiaojing
    Xiao, Qiuyue
    Zhang, Yanting
    Sun, Wei
    Xie, Yuji
    Zeng, Qingyu
    Chen, Yihan
    Jin, Qiaofeng
    Wu, Wenqian
    Yang, Yali
    Wang, Jing
    Lv, Qing
    Shi, Heshui
    Xie, Mingxing
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2021, 34 (05) : 472 - 482
  • [50] Three-Dimensional Magnetic Resonance Fingerprinting in Neonates Quantifying Regional Difference and Maturation in the Brain
    Yu, Nali
    Kim, Jee Young
    Han, Dongyeob
    Kim, So Young
    Lee, Hye Mi
    Kim, Dong-Hyun
    Kim, Hyun Gi
    INVESTIGATIVE RADIOLOGY, 2022, 57 (01) : 44 - 51