Comparison of Three-Dimensional Proximal Isovelocity Surface Area to Cardiac Magnetic Resonance Imaging for Quantifying Mitral Regurgitation

被引:24
|
作者
Brugger, Nicolas [1 ]
Wustmann, Kerstin [1 ]
Huerzeler, Michael [1 ]
Wahl, Andreas [1 ]
de Marchi, Stefano F. [1 ]
Steck, Helene [1 ]
Zuercher, Fabian [1 ]
Seiler, Christian [1 ]
机构
[1] Univ Hosp Bern, Dept Cardiol, CH-3010 Bern, Switzerland
关键词
COLOR DOPPLER-ECHOCARDIOGRAPHY; FLOW CONVERGENCE; IN-VITRO; QUANTIFICATION; VALIDATION; RECOMMENDATIONS;
D O I
10.1016/j.amjcard.2015.01.550
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of our study was to evaluate 3-dimensional (3D) color Doppler proximal isovelocity surface area (PISA) as a tool for quantitative assessment of mitral regurgitation (MR) against in vitro and in vivo reference methods. A customized 3D PISA software was validated in vitro against a flowmeter MR phantom. Sixty consecutive patients, with >= mild MR of any cause, were recruited and the regurgitant volume (RVol) was measured by 2D PISA, 3D peak PISA, and 3D integrated PISA, using transthoracic (TTE) and transesophageal echocardiography (TEE). Cardiac magnetic resonance imaging (CMR) was used as reference method. Flowmeter RVol was associated with 3D integrated PISA as follows: y = 0.64x + 4.7, r(2) = 0.97, p < 0.0001 for TEE and y = 0.88x + 4.07, r(2) = 0.96, p < 0.0001 for TTE. The bias and limit of agreement in the Bland-Altman analysis were 6.8 ml [-3.5 to 17.1] for TEE and -0.059 ml [-6.2 to 6.1] for TTE. In vivo, TEE-derived 3D integrated PISA was the most accurate method for MR quantification compared to CMR: r(2) = 0.76, y = 0.95x - 3.95, p < 0.0001; 5.1 ml (-14.7 to 26.5). It was superior to TEE 3D peak PISA (r(2) = 0.67, y = 1.00x + 6.20, p < 0.0001; -6.3 ml [-33.4 to 21.0]), TEE 2D PISA (r(2) = 0.54,y = 0.76x + 0.18, p < 0.0001; 8.4 ml [-20.4 to 37.2]), and TTE-derived measurements. It was also most accurate by receiver operating characteristic analysis (area under the curve 0.99) for the detection of severe MR, RVol cutoff = 48 ml, sensibility 100%, and specificity 96%. RVol and the cutoff to define severe MR were underestimated using the most accurate method. In conclusion, quantitative 3D color Doppler echocardiography of the PISA permits a more accurate MR assessment than conventional techniques and, consequently, should enable an optimized management of patients suffering from MR. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1130 / 1136
页数:7
相关论文
共 50 条
  • [31] Three-Dimensional Field Optimization Method: Clinical Validation of a Novel Color Doppler Method for Quantifying Mitral Regurgitation
    Tan, Timothy C.
    Zeng, Xin
    Jiao, Yuan
    Wang, Lin
    Wei, Qifeng
    Thiele, Karl
    Salgo, Ivan
    Mehta, Vipin
    Andrawes, Michael
    Picard, Michael H.
    Hung, Judy
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2016, 29 (10) : 926 - 934
  • [32] Right ventricular remodelling in pulmonary arterial hypertension with three-dimensional echocardiography: comparison with cardiac magnetic resonance imaging
    Grapsa, Julia
    O'Regan, Declan P.
    Pavlopoulos, Harry
    Durighel, Giuliana
    Dawson, David
    Nihoyannopoulos, Petros
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (01): : 64 - 73
  • [33] Prospective Comparison of Valve Regurgitation Quantitation by Cardiac Magnetic Resonance Imaging and Transthoracic Echocardiography
    Cawley, Peter J.
    Hamilton-Craig, Christian
    Owens, David S.
    Krieger, Eric V.
    Strugnell, Wendy E.
    Mitsumori, Lee
    D'Jang, Caryn L.
    Schwaegler, Rebecca G.
    Nguyen, Khanh Q.
    Bianca Nguyen
    Maki, Jeffrey H.
    Otto, Catherine M.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2013, 6 (01) : 48 - 57
  • [34] Diagnostic value of mitral regurgitant jet volume in the assessment of mitral regurgitation severity by general imaging three-dimensional quantification
    Wang, Wugang
    Jiang, Yong
    Li, Junfang
    Gong, Kun
    Zhao, Liang
    Tang, Guozhang
    Meng, Yuanyuan
    Wang, Zhibin
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (10) : 1963 - 1972
  • [35] Semiautomatic Three-Dimensional Threshold-Based Cardiac Computed Tomography Ventricular Volumetry in Repaired Tetralogy of Fallot: Comparison with Cardiac Magnetic Resonance Imaging
    Goo, Hyun Woo
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (01) : 102 - 113
  • [36] Evaluation of diastolic function by three-dimensional volume tracking of the mitral annulus with cardiovascular magnetic resonance: comparison with tissue Doppler imaging
    Wu, Vincent
    Chyou, Janice Y.
    Chung, Sohae
    Bhagavatula, Sharath
    Axel, Leon
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [37] Quantification of Mitral Regurgitation in Mitral Valve Prolapse by Three-Dimensional Vena Contracta Area: Derived Cutoff Values and Comparison With Two-Dimensional Multiparametric Approach
    Fiore, Giorgio
    Ingallina, Giacomo
    Ancona, Francesco
    Gaspardone, Carlo
    Biondi, Federico
    Margonato, Davide
    Morosato, Michele
    Belli, Martina
    Tavernese, Annamaria
    Stella, Stefano
    Agricola, Eustachio
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2024, 37 (06) : 591 - 598
  • [38] Comparison of Intraoperative Three-Dimensional Doppler Color Flow Mapping to Assess Mitral Regurgitation
    Hien, Maximilian D.
    Weymann, Alexander
    Rauch, Helmut
    Grossgasteiger, Manuel
    Motsch, Johann
    Rosendal, Christian
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (07): : 849 - 857
  • [39] Is Cardiac Magnetic Resonance Imaging the New "Gold Standard'' for Quantitation of Mitral Regurgitation? A Critical Appraisal
    Van de Heyning, Caroline M.
    Magne, Julien
    Cosyns, Bernard
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2019, 32 (01) : 163 - 163
  • [40] Comparison of three-dimensional surface-imaging systems
    Tzou, Chieh-Han John
    Artner, Nicole M.
    Pona, Igor
    Hold, Alina
    Placheta, Eva
    Kropatsch, Walter G.
    Frey, Manfred
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2014, 67 (04) : 489 - 497