Comparison of Three-Dimensional Proximal Isovelocity Surface Area to Cardiac Magnetic Resonance Imaging for Quantifying Mitral Regurgitation

被引:24
|
作者
Brugger, Nicolas [1 ]
Wustmann, Kerstin [1 ]
Huerzeler, Michael [1 ]
Wahl, Andreas [1 ]
de Marchi, Stefano F. [1 ]
Steck, Helene [1 ]
Zuercher, Fabian [1 ]
Seiler, Christian [1 ]
机构
[1] Univ Hosp Bern, Dept Cardiol, CH-3010 Bern, Switzerland
关键词
COLOR DOPPLER-ECHOCARDIOGRAPHY; FLOW CONVERGENCE; IN-VITRO; QUANTIFICATION; VALIDATION; RECOMMENDATIONS;
D O I
10.1016/j.amjcard.2015.01.550
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of our study was to evaluate 3-dimensional (3D) color Doppler proximal isovelocity surface area (PISA) as a tool for quantitative assessment of mitral regurgitation (MR) against in vitro and in vivo reference methods. A customized 3D PISA software was validated in vitro against a flowmeter MR phantom. Sixty consecutive patients, with >= mild MR of any cause, were recruited and the regurgitant volume (RVol) was measured by 2D PISA, 3D peak PISA, and 3D integrated PISA, using transthoracic (TTE) and transesophageal echocardiography (TEE). Cardiac magnetic resonance imaging (CMR) was used as reference method. Flowmeter RVol was associated with 3D integrated PISA as follows: y = 0.64x + 4.7, r(2) = 0.97, p < 0.0001 for TEE and y = 0.88x + 4.07, r(2) = 0.96, p < 0.0001 for TTE. The bias and limit of agreement in the Bland-Altman analysis were 6.8 ml [-3.5 to 17.1] for TEE and -0.059 ml [-6.2 to 6.1] for TTE. In vivo, TEE-derived 3D integrated PISA was the most accurate method for MR quantification compared to CMR: r(2) = 0.76, y = 0.95x - 3.95, p < 0.0001; 5.1 ml (-14.7 to 26.5). It was superior to TEE 3D peak PISA (r(2) = 0.67, y = 1.00x + 6.20, p < 0.0001; -6.3 ml [-33.4 to 21.0]), TEE 2D PISA (r(2) = 0.54,y = 0.76x + 0.18, p < 0.0001; 8.4 ml [-20.4 to 37.2]), and TTE-derived measurements. It was also most accurate by receiver operating characteristic analysis (area under the curve 0.99) for the detection of severe MR, RVol cutoff = 48 ml, sensibility 100%, and specificity 96%. RVol and the cutoff to define severe MR were underestimated using the most accurate method. In conclusion, quantitative 3D color Doppler echocardiography of the PISA permits a more accurate MR assessment than conventional techniques and, consequently, should enable an optimized management of patients suffering from MR. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1130 / 1136
页数:7
相关论文
共 50 条
  • [21] Quantitation of mitral regurgitation with cardiac magnetic resonance imaging: a systematic review
    Krieger, Eric V.
    Lee, James
    Branch, Kelley R.
    Hamilton-Craig, Christian
    HEART, 2016, 102 (23) : 1864 - 1870
  • [22] Assessment of mitral regurgitation by 3-dimensional proximal flow convergence using magnetic resonance imaging: comparison with echo-Doppler
    Gorodisky, Lior
    Agmon, Yoram
    Porat, Moshe
    Abadi, Sobhi
    Lessick, Jonathan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (05) : 793 - 802
  • [23] Quantification of Mitral Valve Regurgitation in Cavalier King Charles Spaniels and Chihuahuas Using Radius of Proximal Isovelocity Surface Area
    Koch, Jorgen
    Engeland, Inge V.
    Willesen, Jakob L.
    Schroder, Anders S.
    Gleerup, Caroline H.
    Bach, Maiken B. T.
    ANIMALS, 2024, 14 (19):
  • [24] Comparison of mitral valve area by pressure half-time and proximal isovelocity surface area method in patients with mitral stenosis: effect of net atrioventricular compliance
    Omar, Alaa Mabrouk Salem
    Tanaka, Hidekazu
    AbdelDayem, Tarek Khairy
    Sadek, Ayman S.
    Raslaan, Halah
    Al-Sherbiny, Ashraf
    Yamawaki, Kohei
    Ryo, Keiko
    Fukuda, Yuko
    Norisada, Kazuko
    Tatsumi, Kazuhiro
    Onishi, Tetsuari
    Matsumoto, Kensuke
    Kawai, Hiroya
    Hirata, Ken-ichi
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (04): : 283 - 290
  • [25] Tissue-based markers of right ventricular dysfunction in ischemic mitral regurgitation assessed via stress cardiac magnetic resonance and three-dimensional echocardiography
    Kim, Jiwon
    Alakbarli, Javid
    Yum, Brian
    Tehrani, Nathan H.
    Pollie, Meridith P.
    Abouzeid, Christiane
    Di Franco, Antonino
    Ratcliffe, Mark B.
    Poppas, Athena
    Levine, Robert A.
    Devereux, Richard B.
    Weinsaft, Jonathan W.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (04) : 683 - 693
  • [26] In vitro and clinical validation of different correction algorithms for the two-dimensional proximal isovelocity surface area method in a low-velocity flow field for quantifying tricuspid regurgitation
    Liu, Yu
    Liu, Li
    Chen, Beiqi
    Wu, Yuanfeng
    Zhao, Rui
    Zuo, Wuxu
    Li, Quan
    Meng, Fangmin
    Kong, Dehong
    Pan, Cuizhen
    Dong, Lili
    Shu, Xianhong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (01) : 160 - 178
  • [27] A three-dimensional insight into the complexity of flow convergence in mitral regurgitation: adjunctive benefit of anatomic regurgitant orifice area
    Chandra, Sonal
    Salgo, Ivan S.
    Sugeng, Lissa
    Weinert, Lynn
    Settlemier, Scott H.
    Mor-Avi, Victor
    Lang, Roberto M.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2011, 301 (03): : H1015 - H1024
  • [28] Cardiac magnetic resonance assessment of mitral regurgitation severity appears better than echocardiographic imaging
    Hassan, Ayman K. M.
    Algowhary, Magdy I.
    Kishk, Aya Y. T.
    Youssef, Amr Ahmed Aly
    Razik, Nady A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (05) : 889 - 897
  • [29] Comparison of Two- and Three-Dimensional Transthoracic Echocardiography to Cardiac Magnetic Resonance Imaging for Assessment of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation
    Altiok, Ertunc
    Frick, Michael
    Meyer, Christian G.
    Al Ateah, Ghazi
    Napp, Andreas
    Kirschfink, Annemarie
    Almalla, Mohammad
    Lotfi, Shahran
    Becker, Michael
    Herich, Lena
    Lehmacher, Walter
    Hoffmann, Rainer
    AMERICAN JOURNAL OF CARDIOLOGY, 2014, 113 (11) : 1859 - 1866
  • [30] Three-Dimensional Field Optimization Method: Gold-Standard Validation of a Novel Color Doppler Method for Quantifying Mitral Regurgitation
    Pierce, Eric L.
    Rabbah, Jean Pierre M.
    Thiele, Karl
    Wei, Qifeng
    Vidakovic, Brani
    Jensen, Morten O.
    Hung, Judy
    Yoganathan, Ajit P.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2016, 29 (10) : 917 - 925