Poor Reliability of Wrist Blood Pressure Self-Measurement at Home: A Population-Based Study

被引:41
作者
Casiglia, Edoardo [1 ]
Tikhonoff, Valerie [1 ]
Albertini, Federica [1 ]
Palatini, Paolo [1 ]
机构
[1] Univ Padua, Dept Med, Via Giustiniani 2, Padua, Italy
关键词
blood pressure; epidemiology; heart; methods; wrist; TERMINAL DIGIT PREFERENCE; PULSE PRESSURE; POSITION SENSOR; ARM POSITION; RISK-FACTORS; HYPERTENSION; IMPACT; DEVICE; VALIDATION; ACCURACY;
D O I
10.1161/HYPERTENSIONAHA.116.07961
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The reliability of blood pressure measurement with wrist devices, which has not previously been assessed under real-life circumstances in general population, is dependent on correct positioning of the wrist device at heart level. We determined whether an error was present when blood pressure was self-measured at the wrist in 721 unselected subjects from the general population. After training, blood pressure was measured in the office and self-measured at home with an upper-arm device (the UA-767 Plus) and a wrist device (the UB-542, not provided with a position sensor). The upper-arm-wrist blood pressure difference detected in the office was used as the reference measurement. The discrepancy between office and home differences was the home measurement error. In the office, systolic blood pressure was 2.5% lower at wrist than at arm (P=0.002), whereas at home, systolic and diastolic blood pressures were higher at wrist than at arm (+5.6% and +5.4%, respectively; P<0.0001 for both); 621 subjects had home measurement error of at least +/- 5 mmHg and 455 of at least +/- 10 mmHg (bad measurers). In multivariable linear regression, a lower cognitive pattern independently determined both the systolic and the diastolic home measurement error and a longer forearm the systolic error only. This was confirmed by logistic regression having bad measurers as dependent variable. The use of wrist devices for home self-measurement, therefore, leads to frequent detection of falsely elevated blood pressure values likely because of a poor memory and rendition of the instructions, leading to the wrong position of the wrist.
引用
收藏
页码:896 / 903
页数:8
相关论文
共 39 条
  • [1] [Anonymous], 2013, BLOOD PRESSURE
  • [2] Ambulatory Blood Pressure Monitoring in 9357 Subjects From 11 Populations Highlights Missed Opportunities for Cardiovascular Prevention in Women
    Boggia, Jose
    Thijs, Lutgarde
    Hansen, Tine W.
    Li, Yan
    Kikuya, Masahiro
    Bjoerklund-Bodegard, Kristina
    Richart, Tom
    Ohkubo, Takayoshi
    Jeppesen, Jorgen
    Torp-Pedersen, Christian
    Dolan, Eamon
    Kuznetsova, Tatiana
    Olszanecka, Agnieszka
    Tikhonoff, Valerie
    Malyutina, Sofia
    Casiglia, Edoardo
    Nikitin, Yuri
    Lind, Lars
    Maestre, Gladys
    Sandoya, Edgardo
    Kawecka-Jaszcz, Kalina
    Imai, Yutaka
    Wang, Jiguang
    Ibsen, Hans
    O'Brien, Eoin
    Staessen, Jan A.
    [J]. HYPERTENSION, 2011, 57 (03) : 397 - U108
  • [3] Pulse pressure and coronary mortality in elderly men and women from general population
    Casiglia, E
    Tikhonoff, V
    Mazza, A
    Piccoli, A
    Pessina, AC
    [J]. JOURNAL OF HUMAN HYPERTENSION, 2002, 16 (09) : 611 - 620
  • [4] Weak effect of hypertension and other classic risk factors in the elderly who have already paid their toll
    Casiglia, E
    Mazza, A
    Tikhonoff, V
    Pavei, A
    Privato, G
    Schenal, N
    Pessina, AC
    [J]. JOURNAL OF HUMAN HYPERTENSION, 2002, 16 (01) : 21 - 31
  • [5] Cardiovascular risk factors in the elderly
    Casiglia, E
    Palatini, P
    [J]. JOURNAL OF HUMAN HYPERTENSION, 1998, 12 (09) : 575 - 581
  • [6] Casiglia E., 2005, Aging Health, V1, P85, DOI [10.2217/1745509X.1.1.85, DOI 10.2217/1745509X.1.1.85]
  • [7] Cognitive Functions across the GNB3 C825T Polymorphism in an Elderly Italian Population
    Casiglia, Edoardo
    Giordano, Nunzia
    Tikhonoff, Valerie
    Boschetti, Giovanni
    Mazza, Alberto
    Caffi, Sandro
    Guidotti, Federica
    Bisiacchi, Patrizia
    [J]. NEUROLOGY RESEARCH INTERNATIONAL, 2013, 2013
  • [8] Comparison of the Omron RS6 wrist blood pressure monitor with the positioning sensor on or off with a standard mercury sphygmomanometer
    Deutsch, Cornelia
    Krueger, Ralf
    Saito, Kanako
    Yamashita, Shingo
    Sawanoi, Yukiya
    Beime, Beate
    Bramlage, Peter
    [J]. BLOOD PRESSURE MONITORING, 2014, 19 (05) : 306 - 313
  • [9] White-Coat and Reverse White-Coat Effects Correlate with 24-h Pulse Pressure and Systolic Blood Pressure Variability in Children and Young Adults
    Fujita, Hisayo
    Matsuoka, Seiji
    Awazu, Midori
    [J]. PEDIATRIC CARDIOLOGY, 2016, 37 (02) : 345 - 352
  • [10] Simple determination of the systolic-diastolic pressure relationship from blood pressure readings taken at different arm heights
    Gavish, Benjamin
    Gavish, Leah
    [J]. BLOOD PRESSURE MONITORING, 2013, 18 (03) : 144 - 150