Catheter Ablation of Ventricular Arrhythmias Arising from the Right Ventricular Septum Close to the His Bundle: Features of the Local Electrogram at the Optimal Ablation Site

被引:22
作者
Komatsu, Yuki [1 ]
Otomo, Kiyoshi [1 ]
Taniguchi, Hiroshi [1 ]
Kakita, Ken [1 ]
Takayama, Kei [1 ]
Fujiwara, Hideomi [1 ]
Iesaka, Yoshito [1 ]
机构
[1] Tsuchiura Kyodo Gen Hosp, Dept Cardiol, Ctr Cardiovasc, Tsuchiura, Ibaraki, Japan
关键词
catheter ablation; His bundle; local electrogram; outflow tract; ventricular arrhythmia; OUTFLOW TRACT; ELECTROCARDIOGRAPHIC CHARACTERISTICS; TACHYCARDIA; ORIGIN; ACTIVATION; UNIPOLAR;
D O I
10.1111/j.1540-8167.2011.02014.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ablation of Para-Hisian Ventricular Arrhythmias. Introduction: The characteristics of the local electrogram at the optimal ablation site of ventricular arrhythmias (VAs) originating from the right ventricle close to the His bundle (HB) region have rarely been described. Methods and Results: Among 190 consecutive patients with idiopathic VAs with left bundle branch block morphology and inferior-axis deviation, 16 were found to have successful ablation site in the right ventricle close to the HB region (para-Hisian group). The electrophysiologic data were compared between the patients in the para-Hisian group and those with VAs arising from the right ventricular (RV) outflow tract (RVOT group). The distal bipolar electrogram at the successful ablation sites in the para-Hisian group exhibited a significantly greater R-wave duration, lower R-wave amplitude, and slower upright deflection of the initial R wave than did those in the RVOT group (all P < 0.001). In the para-Hisian group, a total of 56 radiofrequency (RF) energy applications were delivered, of which the local electrograms at 16 successful and 40 unsuccessful ablation sites were reviewed. High-frequency R-wave potentials of the bipolar electrogram were present in 14 (88%) of the successful ablation sites. An R-wave duration of greater than 34 ms had a discriminatory power for indicating the site of a successful ablation (area under the receiver-operator characteristics curve 0.90, sensitivity 94%, specificity 80%). Conclusions: The successful ablation site of the para-Hisian VAs had distinctive local electrogram characteristics. A longer R-wave duration of the bipolar electrogram with high-frequency potentials could be a novel predictor of a successful ablation. (J Cardiovasc Electrophysiol, Vol. 22, pp. 878-885, August 2011)
引用
收藏
页码:878 / 885
页数:8
相关论文
共 18 条
  • [1] Acute and long-term outcome of transvenous cryoablation of midseptal and parahissian accessory pathways in patients at high risk of atrioventricular block during radiofrequency ablation
    Atienza, F
    Arenal, A
    Torrecilla, EG
    García-Alberola, A
    Jiménez, J
    Ortiz, M
    Puchol, A
    Almendral, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (10) : 1302 - 1305
  • [2] Right meets left: A common mechanism underlying right and left ventricular outflow tract tachycardias
    Bunch, T. Jared
    Day, John D.
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (10) : 1059 - 1061
  • [3] RIGHT VENTRICULAR-TACHYCARDIA - CLINICAL AND ELECTROPHYSIOLOGIC CHARACTERISTICS
    BUXTON, AE
    WAXMAN, HL
    MARCHLINSKI, FE
    SIMSON, MB
    CASSIDY, D
    JOSEPHSON, ME
    [J]. CIRCULATION, 1983, 68 (05) : 917 - 927
  • [4] Repetitive monomorphic tachycardia from the left ventricular outflow tract: Electrocardiographic patterns consistent with a left ventricular site of origin
    Callans, DJ
    Menz, V
    Schwartzman, D
    Gottlieb, CD
    Marchlinski, FE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (05) : 1023 - 1027
  • [5] RADIOFREQUENCY CATHETER ABLATION AS A CURE FOR IDIOPATHIC TACHYCARDIA OF BOTH LEFT AND RIGHT-VENTRICULAR ORIGIN
    COGGINS, DL
    LEE, RJ
    SWEENEY, J
    CHEIN, WW
    VANHARE, G
    EPSTEIN, L
    GONZALEZ, R
    GRIFFIN, JC
    LESH, MD
    SCHEINMAN, MM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (06) : 1333 - 1341
  • [6] Single catheter determination of local electrogram prematurity using simultaneous unipolar and bipolar recordings to replace the surface ECG as a timing reference
    Delacretaz, E
    Soejima, K
    Gottipaty, VK
    Brunckhorst, CB
    Friedman, PL
    Stevenson, WG
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (04): : 441 - 449
  • [7] RADIOFREQUENCY CATHETER ABLATION OF VENTRICULAR-TACHYCARDIA IN PATIENTS WITHOUT STRUCTURAL HEART-DISEASE
    KLEIN, LS
    SHIH, HT
    HACKETT, FK
    ZIPES, DP
    MILES, WM
    [J]. CIRCULATION, 1992, 85 (05) : 1666 - 1674
  • [8] IDIOPATHIC LEFT-VENTRICULAR TACHYCARDIA - NEW INSIGHTS INTO ELECTROPHYSIOLOGICAL CHARACTERISTICS AND RADIOFREQUENCY CATHETER ABLATION
    KOTTKAMP, H
    CHEN, X
    HINDRICKS, G
    WILLEMS, S
    HAVERKAMP, W
    WICHTER, T
    BREITHARDT, G
    BORGGREFE, M
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (06): : 1285 - 1297
  • [9] Accuracy of the unipolar electrogram for identification of the site of origin of ventricular activation
    Man, KC
    Daoud, EG
    Knight, BP
    Bahu, M
    Weiss, R
    Zivin, A
    Souza, SJ
    Goyal, R
    Strickberger, SA
    Morady, F
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (09) : 974 - 979
  • [10] Idiopathic ventricular outflow tract tachycardia: Where does it originate?
    Miles, WM
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (05) : 536 - 537