Simplified low-dose-rate infant total body irradiation

被引:0
作者
Knutson, Nels [1 ]
Rao, Y. James [1 ]
Yaddanapudi, Sridhar [1 ]
Perkins, Stephanie M. [1 ]
Li, H. Harold [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, 4921 Parkview Pl,Campus Box 8224, St Louis, MO 63110 USA
关键词
BONE-MARROW TRANSPLANTATION; DELIVERY; PHOTON; BEAMS;
D O I
10.1016/j.prro.2016.10.013
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Low-dose-rate total body irradiation (LDR TBI) in infants possesses unique challenges because of the setup limitations imposed by anesthesia. We present an LDR TBI method with an anteroposterior/posteroanterior arrangement and dose rate < 10 cGy/minute for infants (thickness <14 cm) without the use of a beam attenuator. Materials and methods: The delivery used a 6 MV TrueBeam linear accelerator (Varian Medical Systems, Palo Alto, CA) with adjustable meterset rates below 100 MU/minute. A platform was constructed to support the patient 6 cm above the floor (similar to 2 m from the source). A 40 x 40 cm(2) field at isocenter along with a 45 degrees collimator rotation was used to achieve a maximum field width of approximately 113 cm at 2 m. The patient was positioned supine with head turned toward the patient's right side for the anteroposterior beam and prone with the head continuing to turn towards the patient's right side for the posteroanterior beam. A scattering plate with custom organ blocks was placed approximately 20 cm from the patient's skin surface. Output, depth-dose, surface-dose, block transmission, and off-axis measurements were taken using solid water slabs, ion chambers, and film. Results: The TrueBeam provides several options for this treatment geometry to deliver LDR TBI at less than 10 cGy/min by lowering the linear accelerator meterset rate below 100 MU/minute. This allowed for a compromise between dose rate and treatment time to be selected by the radiation oncology team without the use of a beam attenuator, thus improving patient safety. Depth-dose and off-axis measurements confirmed a dose distribution within +/- 5% of the central-axis dose. A scattering plate distance of similar to 20 cm from the patient increases surface dose while allowing easy access to the patient during anesthesia. Conclusions: The method described is useful to pediatric radiation oncologists seeking to deliver LDR TBI to an infant patient. (C) 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:190 / 194
页数:5
相关论文
共 50 条
[31]   Phase I study of escalating doses of low-dose-rate, locoregional irradiation preceding cytoxan-TBI for patients with chemotherapy-resistant non-Hodgkin's or Hodgkin's lymphoma [J].
Song, DY ;
Jones, RJ ;
Welsh, JS ;
Haulk, TL ;
Korman, LT ;
Noga, S ;
Goodman, S ;
Herman, M ;
Mann, R ;
Marcellus, D ;
Vogelsang, G ;
Ambinder, RF ;
Abrams, RA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (01) :166-171
[32]   Induction of Severe Cataract and Late Renal Dysfunction Following Total Body Irradiation: Dose-Effect Relationships [J].
Kal, Henk B. ;
Van Kempen-Harteveld, M. Loes .
ANTICANCER RESEARCH, 2009, 29 (08) :3305-3309
[33]   Commissioning of a dedicated commercial Co-60 total body irradiation unit [J].
Burmeister, Jay ;
Nalichowski, Adrian ;
Snyder, Michael ;
Halford, Robert ;
Baran, Geoff ;
Loughery, Brian ;
Hammoud, Ahmad ;
Rakowski, Joe ;
Bossenberger, Todd .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03) :131-141
[34]   Volumetric modulated arc therapy total body irradiation improves toxicity outcomes compared to 2D total body irradiation [J].
Hui, Caressa ;
Simiele, Eric ;
Lozko, Yuliia ;
Romero, Ignacio ;
Skinner, Lawrie ;
Binkley, Michael Sargent ;
Hoppe, Richard ;
Kovalchuk, Nataliya ;
Hiniker, Susan M. .
FRONTIERS IN ONCOLOGY, 2024, 14
[35]   Aperture modulated, translating bed total body irradiation [J].
Hussain, Amjad ;
Villarreal-Barajas, Jose Eduardo ;
Dunscombe, Peter ;
Brown, Derek W. .
MEDICAL PHYSICS, 2011, 38 (02) :932-941
[36]   Patterns of patient specific dosimetry in total body irradiation [J].
Akino, Yuichi ;
McMullen, Kevin P. ;
Das, Indra J. .
MEDICAL PHYSICS, 2013, 40 (04)
[37]   The antioxidant status of patients subjected to total body irradiation [J].
Chevion, S ;
Or, R ;
Berry, EM .
BIOCHEMISTRY AND MOLECULAR BIOLOGY INTERNATIONAL, 1999, 47 (06) :1019-1027
[38]   Radiobiological effects of total body irradiation on the spinal cord [J].
Nevelsky, Alexander ;
Bar-Deroma, Raquel ;
Kuten, Abraham .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2009, 48 (04) :385-389
[39]   High-Dose Total Body Irradiation and Myeloablative Conditioning before Allogeneic Hematopoietic Cell Transplantation: Time to Rethink? [J].
Mohty, Mohamad ;
Malard, Florent ;
Savani, Bipin N. .
BIOLOGY OF BLOOD AND MARROW TRANSPLANTATION, 2015, 21 (04) :620-624
[40]   RATE OF MARROW ENGRAFTMENT DOES NOT APPEAR TO BE ADVERSELY AFFECTED BY EARLY MARROW INFUSION AFTER TOTAL-BODY IRRADIATION [J].
TRICKETT, AE ;
VOWELS, MR ;
SHING, MMK ;
FORD, D ;
LAMPOTANG, R .
EXPERIMENTAL HEMATOLOGY, 1993, 21 (02) :382-384