Transcatheter aortic valve implantation in obese patients: Overcoming technical challenges and maintaining adequate hemodynamic performance using new generation prostheses

被引:10
作者
Kische, Stephan [1 ,2 ]
D'Ancona, Giuseppe [1 ,2 ]
Agma, Huseyin U. [1 ,2 ]
El-Achkar, Gihan [3 ]
Dissmann, Martin [3 ]
Ortak, Jasmin [1 ,2 ]
Oener, Alper [1 ,2 ]
Ketterer, Ulrike [1 ,2 ]
Baerisch, Anne [1 ,2 ]
Levenson, Benny [4 ]
Ince, Hueseyin [1 ,2 ]
机构
[1] Vivantes Klinikum Friedrichshain & Urban, Dept Cardiol, Berlin, Germany
[2] Univ Rostock, Med Ctr, Rostock, Germany
[3] Vivantes Humboldt Klinikum, Dept Cardiol, Berlin, Germany
[4] St Gertrauden Hosp, Dept Cardiol, Berlin, Germany
关键词
Trans-catheter; Aortic valve; Obesity; Second generation; BODY-MASS INDEX; OUTCOMES; REPLACEMENT; SURVIVAL;
D O I
10.1016/j.ijcard.2016.06.155
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Second-generation TAVI prostheses may enhance the procedure reducing operative time and complications rate, maintaining adequate valve hemodynamic performance. We present our results with 2 new generation trans-catheter aortic valve (TAVI) prostheses in obese patients. Methods: A series of 172 patients underwent trans-femoral TAVI with new generation prostheses (Direct Flow Medical, DFM (R), and LOTUS (R)). Two groups were identified according to body mass index (BMI): group NO (125) BMI < 30 kg/m(2) and group O (47) BMI >= 30 kg/m(2). Results: Trans-femoral approach was possible in all patients without conversion to conventional surgery/cardiopulmonary bypass. Operative/fluoroscopy time and contrast use were comparable. Vascular and bleeding complications were also equally represented in the 2 groups. Thirty-day mortality was 7.2% in group NO and 6.4% in group O (p = 0.9). At discharge, aortic regurgitation was absent/mild in 96% of group NO and in all patients in group O (p = 0.3). Mild prosthetic stenosis was reported in 3.8% of the patients in group NO and 2.2% in group O. No moderate/severe prosthetic stenosis was reported. Estimated 1-year survival was 93.1% in group NO and 83.2% in group O (p = 0.6). Estimated 1-year freedom from MACCE was 74.7% in group NO and 62.8% in group O (p = 0.4). At follow-up echocardiography no significant differences were noticed in the 2 groups. Conclusions: Second generation TAVI prostheses allow for safe and effective procedures in obese patients. In spite of patient's body habitus, agile prosthesis placement will lead to optimized hemodynamics. Valve and clinical performance are confirmed at follow-up. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:909 / 913
页数:5
相关论文
共 10 条
[1]   Impact of Body Mass Index on the Outcomes Following Transcatheter Aortic Valve Implantation [J].
Abramowitz, Yigal ;
Chakravarty, Tarun ;
Jilaihawi, Hasan ;
Cox, Justin ;
Sharma, Rahul P. ;
Mangat, Geeteshwar ;
Nakamura, Mamoo ;
Cheng, Wen ;
Makkar, Raj R. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (01) :127-134
[2]  
Johnson AP, 2015, J AM HEART ASS, V4
[3]   Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document [J].
Kappetein, A. Pieter ;
Head, Stuart J. ;
Genereux, Philippe ;
Piazza, Nicolo ;
van Mieghem, Nicolas M. ;
Blackstone, Eugene H. ;
Brott, Thomas G. ;
Cohen, David J. ;
Cutlip, Donald E. ;
van Es, Gerrit-Anne ;
Hahn, Rebecca T. ;
Kirtane, Ajay J. ;
Krucoff, Mitchell W. ;
Kodali, Susheel ;
Mack, Michael J. ;
Mehran, Roxana ;
Rodes-Cabau, Josep ;
Vranckx, Pascal ;
Webb, John G. ;
Windecker, Stephan ;
Serruys, Patrick W. ;
Leon, Martin B. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (01) :6-23
[4]   Body Mass Index Association With Survival in Severe Aortic Stenosis Patients Undergoing Transcatheter Aortic Valve Replacement [J].
Koifman, Edward ;
Kiramijyan, Sarkis ;
Negi, Smita I. ;
Didier, Romain ;
Escarcega, Ricardo O. ;
Minha, Sa'ar ;
Gai, Jiaxing ;
Torguson, Rebecca ;
Okubagzi, Petros ;
Ben-Dor, Itsik ;
Satler, Lowell F. ;
Pichard, Augusto D. ;
Waksman, Ron .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (01) :118-124
[5]   The Obesity Paradox in Patients Undergoing Transcatheter Aortic Valve Implantation [J].
Konigstein, Maayan ;
Havakuk, Ofer ;
Arbel, Yaron ;
Finkelstein, Ariel ;
Ben-Assa, Eyal ;
Rubinow, Eran Leshem ;
Abramowitz, Yigal ;
Keren, Gad ;
Banai, Shmuel .
CLINICAL CARDIOLOGY, 2015, 38 (02) :76-81
[6]   Imaging in Transcatheter Aortic Valve Replacement (TAVR): Role of the radiologist [J].
Litmanovich D.E. ;
Ghersin E. ;
Burke D.A. ;
Popma J. ;
Shahrzad M. ;
Bankier A.A. .
Insights into Imaging, 2014, 5 (1) :123-145
[7]   1-Year Outcomes With the Fully Repositionable and Retrievable Lotus Transcatheter Aortic Replacement Valve in 120 High-Risk Surgical Patients With Severe Aortic Stenosis Results of the REPRISE II Study [J].
Meredith, Ian T. ;
Walters, Darren L. ;
Dumonteil, Nicolas ;
Worthley, Stephen G. ;
Tchetche, Didier ;
Manoharan, Ganesh ;
Blackman, Daniel J. ;
Rioufol, Gilles ;
Hildick-Smith, David ;
Whitbourn, Robert J. ;
Lefevre, Thierry ;
Lange, Ruediger ;
Mueller, Ralf ;
Redwood, Simon ;
Feldman, Ted E. ;
Allocco, Dominic J. ;
Dawkins, Keith D. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (04) :376-384
[8]   Prospective Multicenter Evaluation of the Direct Flow Medical Transcatheter Aortic Valve [J].
Schofer, Joachim ;
Colombo, Antonio ;
Klugmann, Silvio ;
Fajadet, Jean ;
DeMarco, Federico ;
Tchetche, Didier ;
Maisano, Francesco ;
Bruschi, Giuseppe ;
Latib, Azeem ;
Bijuklic, Klaudija ;
Weissman, Neil ;
Low, Reginald ;
Thomas, Martyn ;
Young, Christopher ;
Redwood, Simon ;
Mullen, Michael ;
Yap, John ;
Grube, Eberhard ;
Nickenig, Georg ;
Sinning, Jan-Malte ;
Hauptmann, Karl Eugen ;
Friedrich, Ivar ;
Lauterbach, Michael ;
Schmoeckel, Michael ;
Davidson, Charles ;
Lefevre, Thierry .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (08) :763-768
[9]   Effect of Body Mass Index on Short- and Long-Term Outcomes After Transcatheter Aortic Valve Implantation [J].
van der Boon, Robert M. A. ;
Chieffo, Alaide ;
Dumonteil, Nicolas ;
Tchetche, Didier ;
Van Mieghem, Nicolas M. ;
Buchanan, Gill L. ;
Vandat, Olivier ;
Marcheix, Bertrand ;
Serruys, Patrick W. ;
Fajadet, Jean ;
Colombo, Antonio ;
Carrie, Didier ;
van Domburg, Ron T. ;
de Jaegere, Peter P. T. .
AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (02) :231-236
[10]   Effect of Body Mass Index on 30-and 365-Day Complication and Survival Rates of Transcatheter Aortic Valve Implantation (from the FRench Aortic National Core Valve and Edwards 2 [FRANCE 2] Registry) [J].
Yamamoto, Masanori ;
Mouillet, Gauthier ;
Oguri, Atsushi ;
Gilard, Martine ;
Laskar, Marc ;
Eltchaninoff, Helene ;
Fajadet, Jean ;
Iung, Bernard ;
Donzeau-Gouge, Patrick ;
Leprince, Pascal ;
Leuguerrier, Alain ;
Prat, Alain ;
Lievre, Michel ;
Chevreul, Karine ;
Dubois-Rande, Jean-Luc ;
Teiger, Emmanuel .
AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (12) :1932-1937