Preparation of dual-dummy-template molecularly imprinted polymers coated magnetic graphene oxide for separation and enrichment of phthalate esters in water

被引:192
作者
Guo, Lihui [1 ]
Ma, Xiaoguo [1 ]
Xie, Xiaowen [1 ]
Huang, Renfeng [1 ]
Zhang, Mengyuan [1 ]
Li, Jing [1 ]
Zeng, Guolong [1 ]
Fan, Yinming [1 ]
机构
[1] Guangdong Univ Technol, Sch Environm Sci & Engn, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Molecularly imprinted polymers; Phthalate esters; Dual-dummy-template; Solid-phase extraction; Detection; SOLID-PHASE EXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; MESOPOROUS SILICA; ACID-ESTERS; SELECTIVE DETERMINATION; EFFICIENT REMOVAL; AQUEOUS-SOLUTION; MICROEXTRACTION; NANOPARTICLES; SAMPLES;
D O I
10.1016/j.cej.2018.12.076
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A novel molecularly imprinted polymers (MIPs) was prepared by the sol-gel imprinting method on the surface of magnetic graphene oxide (MGO) modified with mesoporous silica (mSiO(2)), with dipropyl phthalate (DPRP) and diisononyl phthalate (DINP) as the dual-dummy templates. The prepared MIPs, which was characterized by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), etc., was subsequently employed for simultaneous separation and enrichment of six typical phthalates esters (PAEs) in water. Moreover, the adsorption performance of MIPs was evaluated by means of adsorption isotherms, kinetics and selectivity experiments. Results demonstrated that the adsorption process followed the pseudo-second-order kinetic model, with an equilibrium time of about 120 min and the equilibrium adsorption capacities of MIPs for PAEs ranging from 2.3 to 4.8 mg g(-1) at 298 K. Besides, the prepared MIPs exhibited favorable selectivity and reusability for PAEs. Furthermore, an analytical method was proposed for determining trace PAEs in water samples by gas chromatography/mass spectrometry (GC/MS) combined with solid-phase extraction (SPE) using MIPs as the adsorbent. Factors that affected the extraction efficiency of PAEs were also examined and optimized. It was found that the limits of detection (LODs) and the limits of quantity (LOQs) for PAEs were 0.01-0.05 mu g L-1 and 0.05-0.2 mu g L-1, respectively. The spiked recoveries for PAEs were > 92.9%, with the relative standard deviations (RSDs) of <3.8%. Consequently, the synthesized MIPs can serve as a promising material for the selective detection and removal of PAEs from water.
引用
收藏
页码:245 / 255
页数:11
相关论文
共 42 条
[1]   Multi-walled carbon nanotubes packed cartridge for the solid-phase extraction of several phthalate esters from water samples and their determination by high performance liquid chromatography [J].
Cai, YQ ;
Jiang, GB ;
Liu, JF ;
Zhou, QX .
ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) :149-156
[2]   Phthalate Esters in Foods: Sources, Occurrence, and Analytical Methods [J].
Cao, Xu-Liang .
COMPREHENSIVE REVIEWS IN FOOD SCIENCE AND FOOD SAFETY, 2010, 9 (01) :21-43
[3]   Environmental impact of phthalic acid esters and their removal from water and sediments by different technologies - A review [J].
Daiem, Mahmoud M. Abdel ;
Rivera-Utrilla, Jose ;
Ocampo-Perez, Raul ;
Mendez-Diaz, Jose D. ;
Sanchez-Polo, Manuel .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2012, 109 :164-178
[4]   Phthalate esters in the environment: A critical review of their occurrence, biodegradation, and removal during wastewater treatment processes [J].
Gao, Da-Wen ;
Wen, Zhi-Dan .
SCIENCE OF THE TOTAL ENVIRONMENT, 2016, 541 :986-1001
[5]   Graphene: Status and Prospects [J].
Geim, A. K. .
SCIENCE, 2009, 324 (5934) :1530-1534
[6]   Noncovalent Functionalization of Graphene and Graphene Oxide for Energy Materials, Biosensing, Catalytic, and Biomedical Applications [J].
Georgakilas, Vasilios ;
Tiwari, Jitendra N. ;
Kemp, K. Christian ;
Perman, Jason A. ;
Bourlinos, Athanasios B. ;
Kim, Kwang S. ;
Zboril, Radek .
CHEMICAL REVIEWS, 2016, 116 (09) :5464-5519
[7]   Automated Dispersive Liquid-Liquid Microextraction-Gas Chromatography-Mass Spectrometry [J].
Guo, Liang ;
Lee, Hian Kee .
ANALYTICAL CHEMISTRY, 2014, 86 (08) :3743-3749
[8]   Liquid phase microextraction based on the solidification of a floating ionic liquid combined with high-performance liquid chromatography for the preconcentration of phthalate esters in environmental waters and in bottled beverages [J].
Hu, Lu ;
Shan, Wanyu ;
Zhang, Ying ;
Li, Songqing ;
Gao, Haixiang ;
Lu, Runhua ;
Zhang, Sanbing ;
Zhou, Wenfeng .
RSC ADVANCES, 2016, 6 (43) :36223-36230
[9]   Surfactant-templated organic functionalized mesoporous silica with phosphino ligands [J].
Hu, QY ;
Hampsey, JE ;
Jiang, N ;
Li, CJ ;
Lu, YF .
CHEMISTRY OF MATERIALS, 2005, 17 (06) :1561-1569
[10]   Hydrophilic gallic acid-imprinted polymers over magnetic mesoporous silica microspheres with excellent molecular recognition ability in aqueous fruit juices [J].
Hu, Xin ;
Xie, Lianwu ;
Guo, Junfang ;
Li, Hui ;
Jiang, Xinyu ;
Zhang, Yuping ;
Shi, Shuyun .
FOOD CHEMISTRY, 2015, 179 :206-212