Analyses of non-steroidal anti-inflammatory drugs by on-line concentration capillary electrochromatography using poly(stearyl methacrylate-divinylbenzene) monolithic columns

被引:17
作者
Hsu, Chao-Hsiang
Cheng, Yi-Jie
Singco, Brenda
Huang, Hsi-Ya [1 ]
机构
[1] Chung Yuan Christian Univ, Dept Chem, Chungli 320, Taiwan
关键词
Capillary electrochromatography; On-line concentration; CEC-MS; Non-steroidal anti-inflammatory drugs; Water sample; PERFORMANCE LIQUID-CHROMATOGRAPHY; SAMPLE STACKING STRATEGIES; STATIONARY PHASES; MASS-SPECTROMETRY; EMERGING CONTAMINANTS; SEPARATION; PRECONCENTRATION; ELECTROPHORESIS; PHARMACEUTICALS; FABRICATION;
D O I
10.1016/j.chroma.2010.11.040
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study describes the ability of on-line concentration capillary electrochromatography (CEC) coupled with UV or mass spectrometry (MS) for the determination of nine common non-steroidal antiinflammatory drugs (NSAIDs) in water samples. A series of poly(stearyl methacrylate-divinylbenzene) (poly(SMA-DVB)) monolithic columns, which were prepared by single step in situ polymerization of divinylbenzene (DVB), stearyl methacrylate (SMA) and vinylbenzenesulfonic acid (VBSA, charged monomer), were developed as separation columns for the first time. The effects of polymerization condition of monolithic columns on analyte separations were examined, and the results indicated that separation performances were markedly improved in monolithic columns prepared with short reaction time (3 h) and low SMA:DVB ratio (40/60 ratio of SMA:DVB). Subsequently, an on-line concentration step of step-gradient elution was combined to this CEC system, and by optimizing the difference in eluent strength between the sample matrix and mobile phase, all NSAIDs detection sensitivity were improved (limit of detection (LOD) was 3.4-10 mu g/L for UV, and 0.01-0.19 mu g/L for MS). When compared to the best CE and LC reports on NSAIDs analyses so far, this on-line concentration CEC method provided better detection ability within shorter separation time (12 min) when either UV or MS detector was employed. This is the first report for on-line concentration CEC with MS detection applied in trace solute analyses of real samples. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:350 / 358
页数:9
相关论文
共 53 条
[1]   The use of novel water-in-oil microemulsions in microemulsion electrokinetic chromatography [J].
Altria, KD ;
Broderick, MF ;
Donegan, S ;
Power, J .
ELECTROPHORESIS, 2004, 25 (4-5) :645-652
[2]   Online preconcentration using monoliths in ellectrochromatography capillary format and microchips [J].
Augustin, Violaine ;
Proczek, Gaelle ;
Dugay, Jose ;
Descroix, Stephanie ;
Hennion, Marie-Claire .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (17) :2858-2865
[3]  
Bedair M, 2002, ELECTROPHORESIS, V23, P2938, DOI 10.1002/1522-2683(200209)23:17<2938::AID-ELPS2938>3.0.CO
[4]  
2-8
[5]   Enantioselective determination of ibuprofen in plasma by high-performance liquid chromatography-electrospray mass spectrometry [J].
Bonato, PS ;
Del Lama, MPFM ;
de Carvalho, R .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (02) :413-420
[6]   Fritless capillary columns for HPLC and CEC prepared by immobilizing the stationary phase in an organic polymer matrix [J].
Chirica, GS ;
Remcho, VT .
ANALYTICAL CHEMISTRY, 2000, 72 (15) :3605-3610
[7]   Electrokinetic supercharging for on-line preconcentration of seven non-steroidal anti-inflammatory drugs in water samples [J].
Dawod, Mohamed ;
Breadmore, Michael C. ;
Guijt, Rosanne M. ;
Haddad, Paul R. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) :278-284
[8]   Separation of negatively charged nonsteroidal anti-inflammatory drugs by reversed-phase capillary electrochromatography [J].
De Rossi, A ;
Desiderio, C .
JOURNAL OF CHROMATOGRAPHY A, 2003, 984 (02) :283-290
[9]   Capillary electrochromatography and capillary electrochromatography-electrospray mass spectrometry for the separation of non-steroidal anti-inflammatory drugs [J].
Desiderio, C ;
Fanali, S .
JOURNAL OF CHROMATOGRAPHY A, 2000, 895 (1-2) :123-132
[10]   Recent advances in the control of morphology and surface chemistry of porous polymer-based monolithic stationary phases and their application in CEC [J].
Eeltink, Sebastiaan ;
Svec, Frantisek .
ELECTROPHORESIS, 2007, 28 (1-2) :137-147