Boron doped diamond thin films for the electrochemical detection of SARS-CoV-2 S1 protein

被引:16
作者
Witt, Suzanne [1 ]
Rogien, Alexis [1 ,2 ]
Werner, Diana [1 ]
Siegenthaler, James [1 ]
Lesiyon, Raymond [1 ]
Kurien, Noelle [1 ,2 ]
Rechenberg, Robert [1 ]
Baule, Nina [1 ]
Hardy, Aaron [1 ]
Becker, Michael [1 ]
机构
[1] Fraunhofer USA, Ctr Midwest, 1449 Engn Res Ct, E Lansing, MI 48824 USA
[2] Michigan State Univ, Chem Engn & Mat Sci Dept, 428 S Shaw Ln 2100, E Lansing, MI 48824 USA
关键词
SARS-CoV-2; Boron doped diamond; Biosensor; Impedimetric sensor; DOPING LEVEL; ELECTRODES;
D O I
10.1016/j.diamond.2021.108542
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Amidst a global pandemic, a precise and widely accessible rapid detection method is needed for accurate diagnosis and contact tracing. The lack of this technology was exposed through the outbreak of SARS-CoV-2 beginning in 2019. This study sets the foundation for the development of a boron doped diamond (BDD)based impedimetric sensor. While specifically developed for use in the detection of SARS-CoV-2, this technology uses principles that could be adapted to detect other viruses in the future. Boron doped polycrystalline diamond electrodes were functionalized with a biotin-streptavidin linker complex and biotinylated anti-SARS-CoV-2 S1 antibodies. Electrodes were then incubated with the S1 subunit of the SARS-CoV-2 spike surface protein, and an electrical response was recorded using the changes to the electrode's charge transfer resistance (Rct), measured through electrochemical impedance spectroscopy (EIS). Detectable changes in the Rct were observed after 5-min incubation periods with S1 subunit concentrations as low as 1 fg/mL. Incubation with Influenza-B Hemagglutinin protein resulted in minimal change to the Rct, indicating specificity of the BDD electrode for the S1 subunit of SARS-CoV-2. Detection of the S1 subunit in a complex (cell culture) medium was also demonstrated by modifying the EIS protocol to minimize the effects of sample matrix binding. BDD films of varying surface morphologies were investigated, and material characterization was used to give insight into the microstructure-performance relationship of the BDD sensing surface.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Computational aptamer design for spike glycoprotein (S) (SARS CoV-2) detection with an electrochemical aptasensor
    Cossettini, Alessia
    Pasquardini, Laura
    Romani, Antonello
    Feriani, Aldo
    Pinamonti, Debora
    Manzano, Marisa
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2024, 108 (01)
  • [42] Electrochemical degradation of 17β-estradiol (E2) at boron-doped diamond (Si/BDD) thin film electrode
    Murugananthan, M.
    Yoshihara, S.
    Rakuma, T.
    Uehara, N.
    Shirakashi, T.
    ELECTROCHIMICA ACTA, 2007, 52 (09) : 3242 - 3249
  • [43] Combining hybrid nanoflowers with hybridization chain reaction for highly sensitive detection of SARS-CoV-2 nucleocapsid protein
    Yin, Wen
    Hu, Ji
    Chen, Fang
    Zhu, Li
    Ma, Yingxin
    Wang, Nuo
    Wei, Hongping
    Yang, Hang
    Chou, Shan-Ho
    He, Jin
    ANALYTICA CHIMICA ACTA, 2023, 1279
  • [44] Ultrasensitive detection of SARS-CoV-2 spike protein in untreated saliva using SERS-based biosensor
    Zhang, Meiling
    Li, Xiaodan
    Pan, Jialin
    Zhang, Youlin
    Zhang, Ling
    Wang, Chenguang
    Yan, Xu
    Liu, Xiaomin
    Lu, Geyu
    BIOSENSORS & BIOELECTRONICS, 2021, 190
  • [45] An electrochemiluminescence biosensor based on morphology controlled iridium complex nanomaterials for SARS-CoV-2 nucleocapsid protein detection
    Wen, Yu
    Yang, Guomin
    Zhao, Jinwen
    He, Ying
    Yuan, Ruo
    Chen, Shihong
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 371
  • [46] Detection of antibodies against SARS-CoV-2 spike protein by gold nanospikes in an opto-microfluidic chip
    Funari, Riccardo
    Chu, Kang-Yu
    Shen, Amy Q.
    BIOSENSORS & BIOELECTRONICS, 2020, 169
  • [47] Electrochemical Signatures as a Diagnostic Tool for SARS-CoV-2 and Its Variant Detection in Real-Time Wastewater Samples
    Tharak, Athmakuri
    Asritha, Bodapati
    Mohan, S. Venkata
    ACS ES&T WATER, 2024, 4 (10): : 4474 - 4485
  • [48] Systematic Study of Various Functionalization Steps for Ultrasensitive Detection of SARS-CoV-2 with Direct Laser-Functionalized Au-LIG Electrochemical Sensors
    Brustoloni, Caroline Ji-Mei
    Khamsi, Pouya Soltan
    Kammarchedu, Vinay
    Ebrahimi, Aida
    ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (37) : 49041 - 49052
  • [49] Electrochemical reduction of 3-phenyl-1, 2-benzisoxazole 2-oxide on boron-doped diamond
    Kociolek, Martin
    Bennett, Jason
    Casbohm, Jerry
    JOURNAL OF PHYSICAL ORGANIC CHEMISTRY, 2014, 27 (06) : 540 - 544
  • [50] Poly(3,4-ethylenedioxythiophene) Nanorod Arrays-Based Organic Electrochemical Transistor for SARS-CoV-2 Spike Protein Detection in Artificial Saliva
    Ali, Syed Atif
    Chen, Ying-Lin
    Tseng, Hsueh-Sheng
    Ayalew, Hailemichael
    She, Jia-Wei
    Gautam, Bhaskarchand
    Tu, Hsiung-Lin
    Hsiao, Yu-Sheng
    Yu, Hsiao-hua
    ACS SENSORS, 2025, 10 (03): : 2007 - 2018