Boron doped diamond thin films for the electrochemical detection of SARS-CoV-2 S1 protein

被引:16
作者
Witt, Suzanne [1 ]
Rogien, Alexis [1 ,2 ]
Werner, Diana [1 ]
Siegenthaler, James [1 ]
Lesiyon, Raymond [1 ]
Kurien, Noelle [1 ,2 ]
Rechenberg, Robert [1 ]
Baule, Nina [1 ]
Hardy, Aaron [1 ]
Becker, Michael [1 ]
机构
[1] Fraunhofer USA, Ctr Midwest, 1449 Engn Res Ct, E Lansing, MI 48824 USA
[2] Michigan State Univ, Chem Engn & Mat Sci Dept, 428 S Shaw Ln 2100, E Lansing, MI 48824 USA
关键词
SARS-CoV-2; Boron doped diamond; Biosensor; Impedimetric sensor; DOPING LEVEL; ELECTRODES;
D O I
10.1016/j.diamond.2021.108542
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Amidst a global pandemic, a precise and widely accessible rapid detection method is needed for accurate diagnosis and contact tracing. The lack of this technology was exposed through the outbreak of SARS-CoV-2 beginning in 2019. This study sets the foundation for the development of a boron doped diamond (BDD)based impedimetric sensor. While specifically developed for use in the detection of SARS-CoV-2, this technology uses principles that could be adapted to detect other viruses in the future. Boron doped polycrystalline diamond electrodes were functionalized with a biotin-streptavidin linker complex and biotinylated anti-SARS-CoV-2 S1 antibodies. Electrodes were then incubated with the S1 subunit of the SARS-CoV-2 spike surface protein, and an electrical response was recorded using the changes to the electrode's charge transfer resistance (Rct), measured through electrochemical impedance spectroscopy (EIS). Detectable changes in the Rct were observed after 5-min incubation periods with S1 subunit concentrations as low as 1 fg/mL. Incubation with Influenza-B Hemagglutinin protein resulted in minimal change to the Rct, indicating specificity of the BDD electrode for the S1 subunit of SARS-CoV-2. Detection of the S1 subunit in a complex (cell culture) medium was also demonstrated by modifying the EIS protocol to minimize the effects of sample matrix binding. BDD films of varying surface morphologies were investigated, and material characterization was used to give insight into the microstructure-performance relationship of the BDD sensing surface.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Detection of the SARS-CoV-2 S protein using AuNPs assisted differential-phase surface plasmon resonance biosensor
    Yang, Jiaping
    Deng, Junpeng
    Liu, Yansheng
    Qin, Zhenle
    Zhou, Jin
    Jia, Xiaobo
    Wang, Guofu
    Weng, Yuqiang
    Ling, Feng
    Zhou, Bin
    SENSORS AND ACTUATORS A-PHYSICAL, 2025, 382
  • [32] A Portable and Disposable Electrochemical Sensor Utilizing Laser-Scribed Graphene for Rapid SARS-CoV-2 Detection
    Wang, Runzhong
    Zhu, Bicheng
    Young, Paul
    Luo, Yu
    Taylor, John
    Cameron, Alan J.
    Squire, Christopher J.
    Travas-Sejdic, Jadranka
    BIOSENSORS-BASEL, 2024, 14 (01):
  • [33] Design parameters optimization of an electrothermal flow biosensor for the SARS-CoV-2 S protein immunoassay
    Sameh Kaziz
    Ibrahim Ben Mariem
    Fraj Echouchene
    Mohamed Hichem Gazzah
    Hafedh Belmabrouk
    Indian Journal of Physics, 2022, 96 : 4091 - 4101
  • [34] Design parameters optimization of an electrothermal flow biosensor for the SARS-CoV-2 S protein immunoassay
    Kaziz, S.
    Ben Mariem, I
    Echouchene, F.
    Gazzah, M. H.
    Belmabrouk, H.
    INDIAN JOURNAL OF PHYSICS, 2022, 96 (14) : 4091 - 4101
  • [35] Electronic field effect detection of SARS-CoV-2 N-protein before the onset of symptoms
    Novodchuk, I.
    Kayaharman, M.
    Prassas, I.
    Soosaipillai, A.
    Karimi, R.
    Goldthorpe, I. A.
    Abdel-Rahman, E.
    Sanderson, J.
    Diamandis, E. P.
    Bajcsy, M.
    Yavuz, M.
    BIOSENSORS & BIOELECTRONICS, 2022, 210
  • [36] Enhanced long-lasting luminescence nanorods for ultrasensitive detection of SARS-CoV-2 N protein
    Wei, Yi
    Song, Menglin
    Li, Lihua
    Ma, Yingjin
    Lao, Xinyue
    Liu, Yuan
    Li, Guogang
    Hao, Jianhua
    SCIENCE CHINA-MATERIALS, 2025, 68 (01) : 253 - 260
  • [37] Electrochemical Immunosensor Platform Using Low-Cost ENIG PCB Finish Electrodes: Application for SARS-CoV-2 Spike Protein Sensing
    Nandeshwar, Ruchira
    Kumar, M. Santhosh
    Kondabagil, Kiran
    Tallur, Siddharth
    IEEE ACCESS, 2021, 9 : 154368 - 154377
  • [38] Structured and graphitized boron doped diamond electrodes: Impact on electrochemical detection of Cd2+ and Pb2+ ions
    Stenclova, Pavla
    Vyskocil, Vlastimil
    Szabo, Ondrej
    Izak, Tibor
    Potocky, Stepan
    Kromka, Alexander
    VACUUM, 2019, 170
  • [39] Applications of Electrochemical and Optical Biosensing Techniques Based on Nanomaterials for Detection of SARS-COV-2 Specific Antibodies: An Update Review
    Jasim, Saade Abdalkareem
    Mahmudiono, Trias
    Opulencia, Maria Jade Catalan
    Bokov, Dmitry Olegovich
    Huy, Dinh Tran Ngoc
    Shamsiev, Djakhangir F.
    Al-qaim, Zahraa Haleem
    Trung, Nguyen Dinh
    Mustafa, Yasser Fakri
    Abdelbasset, Walid Kamal
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (10): : 980 - 997
  • [40] Computational aptamer design for spike glycoprotein (S) (SARS CoV-2) detection with an electrochemical aptasensor
    Cossettini, Alessia
    Pasquardini, Laura
    Romani, Antonello
    Feriani, Aldo
    Pinamonti, Debora
    Manzano, Marisa
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2024, 108 (01)