Isoelectric focusing in a poly(dimethylsiloxane) microfluidic chip

被引:126
|
作者
Cui, HC
Horiuchi, K
Dutta, P
Ivory, CF [1 ]
机构
[1] Washington State Univ, Dept Chem Engn, Pullman, WA 99164 USA
[2] Washington State Univ, Sch Mech & Mat Engn, Pullman, WA 99164 USA
关键词
D O I
10.1021/ac048915+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports the application of ampholyte-based isoelectric focusing in poly(dimethylsiloxane) (PDMS) using methylcellulose (MC) to reduce electroosmosis and peak drift. Although the characteristics of PDMS make it possible to fabricate microfluidic chips using soft lithography, unstable electroosmotic flow (EOF) and cathodic drift are significant problems when this medium is used. Ibis paper demonstrates that EOF is greatly reduced in PDMS by applying a dynamic coat of MC to the channel walls and that higher concentrations of MC can be used to increase the viscosity of the electrode solutions in order to suppress pH gradient drift and reduce "compression" of the pH gradient. To illustrate the effect of MC on performance, several fluorescent proteins were focused in microchip channels 5 mum deep by 300 mum wide by 2 cm long in 3-10 min using broad-range ampholytes at electric field strengths ranging from 25 to 100 V/cm.
引用
收藏
页码:1303 / 1309
页数:7
相关论文
共 50 条
  • [41] Rapid fabrication of microfluidic devices in poly(dimethylsiloxane) by photocopying
    Tan, AM
    Rodgers, K
    Murrihy, JP
    O'Mathuna, C
    Glennon, JD
    LAB ON A CHIP, 2001, 1 (01): : 7 - 9
  • [42] Potentiometric titrations in a poly(dimethylsiloxane)-based microfluidic device
    Ferrigno, R
    Lee, JN
    Jiang, XY
    Whitesides, GM
    ANALYTICAL CHEMISTRY, 2004, 76 (08) : 2273 - 2280
  • [43] Reversible bonding by dimethyl-methylphenylmethoxy siloxane - based stamping technique for reusable poly(dimethylsiloxane) microfluidic chip
    Hong Ha Cao
    Thi Hong Nhung Dinh
    Hamdi, Feriel S.
    Couty, Magdalena
    Martincic, Emile
    Woytasik, Marion
    Dufour-Gergam, Elisabeth
    MICRO & NANO LETTERS, 2015, 10 (05) : 229 - 232
  • [44] Two-Dimensional Isoelectric Focusing OFFGEL and Microfluidic Lab-on-Chip Electrophoresis for Assessing Dissolved Proteins in Seawater
    Garcia-Otero, Natalia
    Pena-Vazquez, Elena
    Carmen Barciela-Alonso, Maria
    Bermejo-Barrera, Pilar
    Moreda-Pineiro, Antonio
    ANALYTICAL CHEMISTRY, 2013, 85 (12) : 5909 - 5916
  • [45] Surface biopassivation of replicated poly(dimethylsiloxane) microfluidic channels and application to heterogeneous immunoreaction with on-chip fluorescence detection
    Linder, V
    Verpoorte, E
    Thormann, W
    de Rooij, NF
    Sigrist, M
    ANALYTICAL CHEMISTRY, 2001, 73 (17) : 4181 - 4189
  • [46] Variable-focusing microlens with microfluidic chip
    Chen, J
    Wang, WS
    Fang, J
    Varahramyan, K
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (05) : 675 - 680
  • [47] Isoelectric focusing in a polymeric micro-fluidic chip.
    Cui, H
    Ivory, CF
    Horiuchi, K
    Dutta, P
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 227 : U97 - U97
  • [48] Native Protein Separation by Isoelectric Focusing and Blue Gel Electrophoresis-Coupled Two-Dimensional Microfluidic Chip Electrophoresis
    Ni Hou
    Yu Chen
    Shiyong Yu
    Zongliang Quan
    Chenhua Pan
    Yulin Deng
    Lina Geng
    Chromatographia, 2014, 77 : 1339 - 1346
  • [49] Hands-Off Preparation of Monodisperse Emulsion Droplets Using a Poly(dimethylsiloxane) Microfluidic Chip for Droplet Digital PCR
    Tanaka, Hironari
    Yamamoto, Shunsuke
    Nakamura, Arichika
    Nakashoji, Yuta
    Okura, Naoald
    Nakamoto, Norimitsu
    Tsukagoshi, Kazuhiko
    Hashimoto, Masahiko
    ANALYTICAL CHEMISTRY, 2015, 87 (08) : 4134 - 4143
  • [50] Native Protein Separation by Isoelectric Focusing and Blue Gel Electrophoresis-Coupled Two-Dimensional Microfluidic Chip Electrophoresis
    Hou, Ni
    Chen, Yu
    Yu, Shiyong
    Quan, Zongliang
    Pan, Chenhua
    Deng, Yulin
    Geng, Lina
    CHROMATOGRAPHIA, 2014, 77 (19-20) : 1339 - 1346