Low radiation dose in computed tomography: the role of iodine

被引:50
|
作者
Aschoff, Andrik J. [1 ]
Catalano, Carlo [2 ]
Kirchin, Miles A. [3 ]
Krix, Martin [4 ]
Albrecht, Thomas [5 ]
机构
[1] Klinikum Kempten, Dept Diagnost & Intervent Radiol & Neuroradiol, Kempten, Germany
[2] Univ Roma La Sapienza, Dept Radiol Sci, Rome, Italy
[3] Bracco Imaging SpA, Global Med & Regulatory Affairs, Milan, Italy
[4] Bracco Imaging Germany, Global Med & Regulatory Affairs, Constance, Germany
[5] Vivantes Klinikum Neukolln, Inst Radiol & Intervent Therapie, Berlin, Germany
来源
BRITISH JOURNAL OF RADIOLOGY | 2017年 / 90卷 / 1076期
关键词
LOW-TUBE-VOLTAGE; CONCENTRATION CONTRAST-MEDIUM; CORONARY CT ANGIOGRAPHY; DUAL-SOURCE CT; AFFIRMED ITERATIVE RECONSTRUCTION; MEDICAL IMAGING PROCEDURES; PULMONARY ANGIOGRAPHY; IONIZING-RADIATION; DELIVERY RATE; CHEST CT;
D O I
10.1259/bjr.20170079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent approaches to reducing radiation exposure during CT examinations typically utilize automated dose modulation strategies on the basis of lower tube voltage combined with iterative reconstruction and other dose-saving techniques. Less clearly appreciated is the potentially substantial role that iodinated contrast media (CM) can play in low-radiation-dose CT examinations. Herein we discuss the role of iodinated CM in low-radiation-dose examinations and describe approaches for the optimization of CM administration protocols to further reduce radiation dose and/or CM dose while maintaining image quality for accurate diagnosis. Similar to the higher iodine attenuation obtained at low-tube-voltage settings, high-iodine-signal protocols may permit radiation dose reduction by permitting a lowering of mAs while maintaining the signal-to-noise ratio. This is particularly feasible in first pass examinations where high iodine signal can be achieved by injecting iodine more rapidly. The combination of low kV and IR can also be used to reduce the iodine dose. Here, in optimum contrast injection protocols, the volume of CM administered rather than the iodine concentration should be reduced, since with high-iodine-concentration CM further reductions of iodine dose are achievable for modern first pass examinations. Moreover, higher concentrations of CM more readily allow reductions of both flow rate and volume, thereby improving the tolerability of contrast administration.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Low contrast medium and radiation dose for hepatic computed tomography perfusion of rabbit VX2 tumor
    Zhang, Cai-Yuan
    Cui, Yan-Fen
    Guo, Chen
    Cai, Jing
    Weng, Ya-Fang
    Wang, Li-Jun
    Wang, Deng-Bin
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (17) : 5259 - 5270
  • [32] Optimization of Radiation Dose Reduction in Cardiac Computed Tomographic Angiography
    Entrikin, Daniel W.
    Leipsic, Jonathon A.
    Carr, J. Jeffrey
    CARDIOLOGY IN REVIEW, 2011, 19 (04) : 163 - 176
  • [33] Diagnostic Performance of Low Radiation Dose and Contrast-Dose Coronary Computed Tomography Angiography in the Detection of Coronary In-Stent Restenosis
    Du, Wang
    Fan, Zhanming
    Wang, Rui
    Xu, Lei
    Li, Jianying
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (08) : 1566 - 1572
  • [34] Lung Cancer Screening Using Low-Dose Computed Tomography
    Hirsch, Brandon
    RADIOLOGIC TECHNOLOGY, 2022, 93 (03) : 303CT - 321CT
  • [35] International variation in radiation dose for computed tomography examinations: prospective cohort study
    Smith-Bindman, Rebecca
    Wang, Yifei
    Chu, Philip
    Chung, Robert
    Einstein, Andrew J.
    Balcombe, Jonathan
    Cocker, Mary
    Das, Marcos
    Delman, Bradley N.
    Flynn, Michael
    Gould, Robert
    Lee, Ryan K.
    Yellen-Nelson, Thomas
    Schindera, Sebastian
    Seibert, Anthony
    Starkey, Jay
    Suntharalingam, Saravanabavaan
    Wetter, Axel
    Wildberger, Joachim E.
    Miglioretti, Diana L.
    BMJ-BRITISH MEDICAL JOURNAL, 2019, 364
  • [36] INFLUENCE OF RADIATION DOSE IN COMPUTED TOMOGRAPHY ON ANTIOXIDANT ENZYME ACTIVITY IN RABBIT ERYTHROCYTES
    Mitrovic, Marko B.
    Ciraj-Bjelac, Olivera F.
    Orescanin-Dusic, Zorana S.
    Blagojevic, Dusko P.
    Nikolic-Kokic, Aleksandra L.
    Tatalovic, Nikola R.
    Krstic, Nikola E.
    Lazarevic-Macanovic, Mirjana V.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2017, 32 (04): : 342 - 349
  • [37] Paediatric cardiac computed tomography: a review of imaging techniques and radiation dose consideration
    Young, Carolyn
    Taylor, Andrew M.
    Owens, Catherine M.
    EUROPEAN RADIOLOGY, 2011, 21 (03) : 518 - 529
  • [38] Reduction of radiation dose according to the type of technology used in cardiac computed tomography
    Courtis, Javier
    Copa Gallardo, Juan
    Dimitroff, Magdalena
    Gonzalez, Analia
    REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA, 2020, 49 (02):
  • [39] Evolution of Coronary Computed Tomography Radiation Dose Reduction at a Tertiary Referral Center
    Ghoshhajra, Brian Burns
    Engel, Leif-Christopher
    Major, Gyoengyi Petra
    Goehler, Alexander
    Techasith, Tust
    Verdini, Daniel
    Do, Synho
    Liu, Bob
    Li, Xinhua
    Sala, Michiel
    Kim, Mi Sung
    Blankstein, Ron
    Prakash, Priyanka
    Sidhu, Manavjot S.
    Corsini, Erin
    Banerji, Dahlia
    Wu, David
    Abbara, Suhny
    Quynh Truong
    Brady, Thomas J.
    Hoffmann, Udo
    Kalra, Manudeep
    AMERICAN JOURNAL OF MEDICINE, 2012, 125 (08): : 764 - 772
  • [40] White Paper of the Society of Computed Body Tomography and Magnetic Resonance on Dual-Energy CT, Part 2: Radiation Dose and Iodine Sensitivity
    Foley, W. Dennis
    Shuman, William P.
    Siegel, Marilyn J.
    Sahani, Dushyant V.
    Boll, Daniel T.
    Bolus, David N.
    De Cecco, Carlo N.
    Kaza, Ravi K.
    Morgan, Desiree E.
    Schoepf, U. Joseph
    Vrtiska, Terri J.
    Yeh, Benjamin M.
    Berland, Lincoln L.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (06) : 846 - 850