Low radiation dose in computed tomography: the role of iodine

被引:55
作者
Aschoff, Andrik J. [1 ]
Catalano, Carlo [2 ]
Kirchin, Miles A. [3 ]
Krix, Martin [4 ]
Albrecht, Thomas [5 ]
机构
[1] Klinikum Kempten, Dept Diagnost & Intervent Radiol & Neuroradiol, Kempten, Germany
[2] Univ Roma La Sapienza, Dept Radiol Sci, Rome, Italy
[3] Bracco Imaging SpA, Global Med & Regulatory Affairs, Milan, Italy
[4] Bracco Imaging Germany, Global Med & Regulatory Affairs, Constance, Germany
[5] Vivantes Klinikum Neukolln, Inst Radiol & Intervent Therapie, Berlin, Germany
关键词
LOW-TUBE-VOLTAGE; CONCENTRATION CONTRAST-MEDIUM; CORONARY CT ANGIOGRAPHY; DUAL-SOURCE CT; AFFIRMED ITERATIVE RECONSTRUCTION; MEDICAL IMAGING PROCEDURES; PULMONARY ANGIOGRAPHY; IONIZING-RADIATION; DELIVERY RATE; CHEST CT;
D O I
10.1259/bjr.20170079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent approaches to reducing radiation exposure during CT examinations typically utilize automated dose modulation strategies on the basis of lower tube voltage combined with iterative reconstruction and other dose-saving techniques. Less clearly appreciated is the potentially substantial role that iodinated contrast media (CM) can play in low-radiation-dose CT examinations. Herein we discuss the role of iodinated CM in low-radiation-dose examinations and describe approaches for the optimization of CM administration protocols to further reduce radiation dose and/or CM dose while maintaining image quality for accurate diagnosis. Similar to the higher iodine attenuation obtained at low-tube-voltage settings, high-iodine-signal protocols may permit radiation dose reduction by permitting a lowering of mAs while maintaining the signal-to-noise ratio. This is particularly feasible in first pass examinations where high iodine signal can be achieved by injecting iodine more rapidly. The combination of low kV and IR can also be used to reduce the iodine dose. Here, in optimum contrast injection protocols, the volume of CM administered rather than the iodine concentration should be reduced, since with high-iodine-concentration CM further reductions of iodine dose are achievable for modern first pass examinations. Moreover, higher concentrations of CM more readily allow reductions of both flow rate and volume, thereby improving the tolerability of contrast administration.
引用
收藏
页数:10
相关论文
共 88 条
[1]   Coronary stent evaluation with coronary computed tomographic angiography: Comparison between low-osmolar, high-iodine concentration iomeprol-400 and iso-osmolar, lower-iodine concentration iodixanol-320 [J].
Andreini, Daniele ;
Pontone, Gianluca ;
Mushtaq, Saima ;
Bartorelli, Antonio L. ;
Conte, Edoardo ;
Bertella, Erika ;
Baggiano, Andrea ;
Annoni, Andrea ;
Formenti, Alberto ;
Ballerini, Giovanni ;
Agostoni, Piergiuseppe ;
Fiorentini, Cesare ;
Pepi, Mauro .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (01) :44-51
[2]   Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches [J].
Bae, Kyongtae T. .
RADIOLOGY, 2010, 256 (01) :32-61
[3]   Risk of cancer from diagnostic X-rays:: estimates for the UK and 14 other countries [J].
Berrington de González, A ;
Darby, S .
LANCET, 2004, 363 (9406) :345-351
[4]   Benefits of sinogram-affirmed iterative reconstruction in 0.4 mSv ultra-low-dose CT of the upper abdomen following transarterial chemoembolisation: comparison to low-dose and standard-dose CT and filtered back projection technique [J].
Bodelle, B. ;
Isler, S. ;
Scholtz, J. -E. ;
Frellesen, C. ;
Luboldt, W. ;
Vogl, T. J. ;
Beeres, M. .
CLINICAL RADIOLOGY, 2016, 71 (01) :E11-E15
[5]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[6]   Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography [J].
Cademartiri, F ;
Mollet, NR ;
Runza, G ;
Bruining, N ;
Hamers, R ;
Somers, P ;
Knaapen, M ;
Verheye, S ;
Midiri, M ;
Krestin, GP ;
de Feyter, PJ .
EUROPEAN RADIOLOGY, 2005, 15 (07) :1426-1431
[7]  
Chadwick KH, 2012, RAD DOSE MULTIDETECT
[8]   Cumulative Exposure to Ionizing Radiation From Diagnostic and Therapeutic Cardiac Imaging Procedures [J].
Chen, Jersey ;
Einstein, Andrew J. ;
Fazel, Reza ;
Krumholz, Harlan M. ;
Wang, Yongfei ;
Ross, Joseph S. ;
Ting, Henry H. ;
Shah, Nilay D. ;
Nasir, Khurram ;
Nallamothu, Brahmajee K. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (09) :702-711
[9]   Cerebral computed tomography angiography using a 70 kVp protocol: improved vascular enhancement with a reduced volume of contrast medium and radiation dose [J].
Cho, Eun-Suk ;
Chung, Tae-Sub ;
Ahn, Sung Jun ;
Chong, KyoungHoon ;
Baek, Jang Hun ;
Suh, Sang Hyun .
EUROPEAN RADIOLOGY, 2015, 25 (05) :1421-1430
[10]   CT Angiography of the Renal Arteries: Comparison of Lower-Tube-Voltage CTA With Moderate-Concentration Iodinated Contrast Material and Conventional CTA [J].
Cho, Eun-Suk ;
Yu, Jeong-Sik ;
Ahn, Jhii-Hyun ;
Kim, Joo Hee ;
Chung, Jae-Joon ;
Lee, Hyeon-Kyeong ;
Lee, Kyung Hee .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (01) :96-102