Reliability and minimal detectible change values for gait kinematics and kinetics in healthy adults

被引:257
作者
Wilken, Jason M. [1 ]
Rodriguez, Kelly M. [1 ]
Brawner, Melissa [1 ]
Darter, Benjamin J. [1 ]
机构
[1] Brooke Army Med Ctr, Ctr Intrepid, Dept Orthoped & Rehabil, Ft Sam Houston, TX 78234 USA
关键词
Reliability; Minimal Detectable Change; Intraclass Correlation Coefficient; Gait analysis; LIMB 3-DIMENSIONAL KINEMATICS; RETEST RELIABILITY; WALKING; REPEATABILITY; CHILDREN; PARAMETERS; SPEED;
D O I
10.1016/j.gaitpost.2011.09.105
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Computerized assessment of gait is commonly used in both research and clinical settings to quantify gait mechanics and detect change in performance. Minimal Detectable Change values have only recently been reported, are only available for patient populations, and in many cases exceed 10 degrees. Twenty nine healthy individuals underwent two biomechanical gait assessments separated by 5.6 (SD 2.2) days, with two raters for each session. All subjects walked at a self selected pace and three controlled velocities. ICC. SEM and MDC for kinematic and kinetic measures were calculated for interrater-intrasession, intrarater-intersession and interrater-intersession. ICC values were in the good to excellent range (r > 0.75) for all kinematic and kinetic variables and all comparisons. M DC values were lower than previously published data for all similar comparisons. The results of the current study suggest that reliability is good to excellent across a range of controlled walking velocities and the introduction of a second rater does not appreciably impact ICC or MDC values. In young healthy adults changes in gait kinematics of greater than approximately 50 can be identified when comparing between sessions. Published by Elsevier B.V.
引用
收藏
页码:301 / 307
页数:7
相关论文
共 50 条
[41]   Reference values and reliability of occlusal force distribution and occlusal time measured by the T-Scan system in adults with healthy dentition [J].
Rubio-Ferrer, Gemma ;
Rovira-Lastra, Bernat ;
Khoury-Ribas, Laura ;
Flores-Orozco, Elan Ignacio ;
Ayuso-Montero, Raul ;
Martinez-Gomis, Jordi .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (06) :558-564
[42]   Reliability and Minimal Detectable Change for Sit-to-Stand Tests and the Functional Gait Assessment for Individuals With Parkinson Disease [J].
Petersen, Cheryl ;
Steffen, Teresa ;
Paly, Elizabeth ;
Dvorak, Leah ;
Nelson, Reid .
JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2017, 40 (04) :223-226
[43]   Test-retest reliability and minimal detectable change for measures of wearable gait analysis system (G-walk) in children with cerebral palsy [J].
Yazici, Melek Volkan ;
Cobanoglu, Gamze ;
Yazici, Gokhan .
TURKISH JOURNAL OF MEDICAL SCIENCES, 2022, 52 (03) :658-666
[44]   The validity and reliability of the OneStep smartphone application under various gait conditions in healthy adults with feasibility in clinical practice [J].
Jesse C. Christensen ;
Ethan C. Stanley ;
Evan G. Oro ;
Hunter B. Carlson ;
Yuval Y. Naveh ;
Rotem Shalita ;
Levi S. Teitz .
Journal of Orthopaedic Surgery and Research, 17
[45]   The validity and reliability of the OneStep smartphone application under various gait conditions in healthy adults with feasibility in clinical practice [J].
Christensen, Jesse C. ;
Stanley, Ethan C. ;
Oro, Evan G. ;
Carlson, Hunter B. ;
Naveh, Yuval Y. ;
Shalita, Rotem ;
Teitz, Levi S. .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
[46]   Enforcing walking speed and step-length affects joint kinematics and kinetics in male and female healthy adults [J].
Gill, Niamh ;
O'Leary, Thomas ;
Roberts, Andrew ;
Liu, Anmin ;
Roerdink, Melvyn ;
Greeves, Julie ;
Jones, Richard .
GAIT & POSTURE, 2023, 103 :223-228
[47]   Standard Error of the Mean and Minimal Detectable Change of Gait Speed in Older Adults Using Japanese Long-Term Care Insurance System [J].
Takada, Yui ;
Tanaka, Shigeharu .
GERONTOLOGY AND GERIATRIC MEDICINE, 2021, 7
[48]   A portable isometric knee extensor strength testing device: test-retest reliability and minimal detectable change scores of the Q-Force ӀӀ in healthy adults [J].
Johanneke Hartog ;
Sandra Dijkstra ;
Joke Fleer ;
Pim van der Harst ;
Massimo A. Mariani ;
Lucas H. V. van der Woude .
BMC Musculoskeletal Disorders, 22
[49]   Validity and reliability of inertial measurement units for measuring gait kinematics in older adults across varying fall risk levels and walking speeds [J].
Yin, Lulu ;
Chen, Peng ;
Xu, Junkai ;
Gong, Yixue ;
Zhuang, Yifang ;
Chen, Yiming ;
Wang, Lin .
BMC GERIATRICS, 2025, 25 (01)
[50]   Test-Retest Reliability and Minimal Detectable Change for the 10-Meter Walk Test in Older Adults With Parkinson's disease [J].
Lang, Jesse T. ;
Kassan, Thomas O. ;
Devaney, Laurie Lee ;
Colon-Semenza, Cristina ;
Joseph, Michael F. .
JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2016, 39 (04) :165-170