Resistance to Flexural Fatigue of Reciproc R25 Files under Continuous Rotation and Reciprocating Movement

被引:102
作者
Gavini, Giulio [1 ]
Caldeira, Celso Luiz
Akisue, Eduardo [2 ]
de Miranda Candeiro, George Taccio [3 ]
Sacaguti Kawakami, Dirce Akemi [2 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Restorat Dent, Endodont Div, BR-05508000 Sao Paulo, Brazil
[2] Univ Santa Cecilia, Sch Dent, Santos, Brazil
[3] Univ Sao Paulo, Sch Dent, Postgrad Program Endodont, BR-05508000 Sao Paulo, Brazil
关键词
Cyclic fatigue; nickel-titanium; rotary files; CYCLIC FATIGUE; ROTARY INSTRUMENTS; SYSTEM; SPEED; LIFE;
D O I
10.1016/j.joen.2011.12.033
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The aim of the present work was to evaluate the resistance to flexural fatigue of Reciproc R25 nickel-titanium files, 25 mm, used in continuous rotation motion or reciprocation motion, in dynamic assays device. Methods: Thirty-six Reciproc R25 files were divided into 2 groups (n = 18) according to kinematics applied, continuous rotary (group CR) and reciprocation motion (group RM). The files were submitted to dynamic assays device moved by an electric engine with 300 rpm of speed that permitted the reproduction of pecking motion. The files run on a ring's groove of temperate steel, simulating instrumentation of a curved root canal with 400 and 5 mm of curvature radius. The fracture of file was detected by sensor of device, and the time was marked. The data were analyzed statistically by Student's t test, with level of significance of 95%. Results: The instruments moved by reciprocating movement reached significantly higher numbers of cycles before fracture (mean, 1787.78 cycles) when compared with instruments moved by continuous rotary (mean, 816.39 cycles). Conclusions: The results showed that the reciprocation motion improves flexural fatigue resistance in nickel-titanium instrument Reciproc R25 when compared with continuous rotation movement. (J Endod 2012;38:684-687)
引用
收藏
页码:684 / 687
页数:4
相关论文
共 29 条
[1]   Scanning electron microscope observations of new and used nickel-titanium rotary files [J].
Alapati, SB ;
Brantley, WA ;
Svec, TA ;
Powers, JM ;
Mitchell, JC .
JOURNAL OF ENDODONTICS, 2003, 29 (10) :667-669
[2]  
Askeland D.R., 2003, SCI ENG MAT
[3]  
Christ HJ, 2008, STUD HEALTH TECHNOL, V133, P56
[4]  
de Melo MCC, 2002, J ENDODONT, V28, P765
[5]   Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement [J].
De-Deus, G. ;
Moreira, E. J. L. ;
Lopes, H. P. ;
Elias, C. N. .
INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (12) :1063-1068
[6]   Influence of previous angular deformation on flexural fatigue resistance of K3 nickel-titanium rotary instruments [J].
Galvao Barbosa, Tabiola Ormiga ;
da Cunha Ponciano Gomes, Jose Antonio ;
Pimenta de Araujo, Marcos Cesar .
JOURNAL OF ENDODONTICS, 2007, 33 (12) :1477-1480
[7]   Fatigue resistance of engine-driven rotary nickel-titanium instruments produced by new manufacturing methods [J].
Gambarini, Gianluca ;
Grande, Nicola Maria ;
Plotino, Gianluca ;
Somma, Francesco ;
Garala, Manish ;
De Luca, Massimo ;
Testarelli, Luca .
JOURNAL OF ENDODONTICS, 2008, 34 (08) :1003-1005
[8]   Effects of Raw Material and Rotational Speed on the Cyclic Fatigue of ProFile Vortex Rotary Instruments [J].
Gao, Yong ;
Shotton, Vincent ;
Wilkinson, Kevin ;
Phillips, Greg ;
Ben Johnson, William .
JOURNAL OF ENDODONTICS, 2010, 36 (07) :1205-1209
[9]   Cyclic Fatigue Resistance of Rotary Nickel-Titanium Instruments Submitted to Nitrogen Ion Implantation [J].
Gavini, Giulio ;
Pessoa, Oscar Faciola ;
Barletta, Fernando Branco ;
Vasconcellos, M. A. Z. ;
Caldeira, Celso Luiz .
JOURNAL OF ENDODONTICS, 2010, 36 (07) :1183-1186
[10]   Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments [J].
Haïkel, Y ;
Serfaty, R ;
Bateman, G ;
Senger, B ;
Allemann, C .
JOURNAL OF ENDODONTICS, 1999, 25 (06) :434-440