A new desalination system using a combination of heat pipe, evacuated tube and parabolic trough collector

被引:128
作者
Mosleh, H. Jafari [1 ]
Mamouri, S. Jahangiri [1 ]
Shafii, M. B. [1 ]
Sima, A. Hakim [2 ]
机构
[1] Sharif Univ Technol, Dept Mech Engn, Tehran, Iran
[2] Sharif Energy Res Inst, Tehran, Iran
基金
美国国家科学基金会;
关键词
Desalination; Solar energy; Parabolic trough collector; Heat pipe; Evacuated tube collector; FLAT-PLATE COLLECTOR; SOLAR WATER-HEATERS; NATURAL CIRCULATION; EXPERIMENTAL VALIDATION; STILL; PERFORMANCE; GLASS; MODE; FLOW; DISTILLATION;
D O I
10.1016/j.enconman.2015.04.028
中图分类号
O414.1 [热力学];
学科分类号
摘要
The solar collectors have been commonly used in desalination systems. Recent investigations show that the use of a linear parabolic trough collector in solar stills can improve the efficiency of a desalination system. In this work, a combination of a heat pipe and a twin-glass evacuated tube collector is utilized with a parabolic trough collector. Results show that the rate of production and efficiency can reach to 0.27 kg/(m(2) h) and 22.1% when aluminum conducting foils are used in the space between the heat pipe and the twin-glass evacuated tube collector to transfer heat from the tube collector to the heat pipe. When oil is used as a medium for the transfer of heat, filling the space between heat pipe and twin-glass evacuated tube collector, the production and efficiency can increase to 0.933 kg/(m(2) h) and 65.2%, respectively. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:141 / 150
页数:10
相关论文
共 48 条
[1]   A novel integrated solar desalination system with a pulsating heat pipe [J].
Abad, H. Kargar Sharif ;
Ghiasi, M. ;
Mamouri, S. Jahangiri ;
Shafii, M. B. .
DESALINATION, 2013, 311 :206-210
[2]   Numerical study of heat and mass transfer in a solar still device: Effect of the glass cover [J].
Alvarado-Juarez, R. ;
Xaman, J. ;
Alvarez, G. ;
Hernandez-Lopez, I. .
DESALINATION, 2015, 359 :200-211
[3]   Theoretical and experimental investigation of heat pipe solar collector [J].
Azad, E. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2008, 32 (08) :1666-1672
[4]   The effect of coupling a flat-plate collector on the solar still productivity [J].
Badran, OO ;
Al-Tahaineh, HA .
DESALINATION, 2005, 183 (1-3) :137-142
[5]  
Bell S., 2001, A Beginner's Guide to Uncertainly o f Measurement
[6]   Simultaneous Multiple Surface method for Linear Fresnel concentrators with tubular receiver [J].
Canavarro, Diogo ;
Chaves, Julio ;
Collares-Pereira, Manuel .
SOLAR ENERGY, 2014, 110 :105-116
[7]   An experimental study of the utilization of heat pipes for solar water heaters [J].
Chun, W ;
Kang, YH ;
Kwak, HY ;
Lee, YS .
APPLIED THERMAL ENGINEERING, 1999, 19 (08) :807-817
[8]   Annual performance of evacuated tubular collector integrated solar still [J].
Dev, Rahul ;
Tiwari, G. N. .
DESALINATION AND WATER TREATMENT, 2012, 41 (1-3) :204-223
[9]   Effect of condensing cover material on yield of an active solar still: an experimental validation [J].
Dimri, Vimal ;
Sarkar, Bikash ;
Singh, Usha ;
Tiwari, G. N. .
DESALINATION, 2008, 227 (1-3) :178-189
[10]   Comparison of internal heat transfer coefficients in passive solar stills by different thermal models: An experimental validation [J].
Dwivedi, V. K. ;
Tiwari, G. N. .
DESALINATION, 2009, 246 (1-3) :304-318