Determination of personal care products in water using UHPLC-MS after solid phase extraction with mesoporous silica-based MCM-41 functionalized with cyanopropyl groups

被引:7
作者
Kharbouche, Leila [1 ,3 ]
Gil Garcia, Maria Dolores [1 ,2 ]
Lozano, Ana [1 ,2 ]
Hamaizi, Hadj [3 ]
Martinez Galera, Maria [1 ,2 ]
机构
[1] Univ Almeria, Dept Chem & Phys, Area Analyt Chem, Almeria 04120, Spain
[2] Campus Excelencia Int Agroalimentario CeiA3, Almeria, Spain
[3] Univ Oran 1, Lab Synth Organ Appl, Dept Chim, Oran, Algeria
关键词
functionalized MCM-41; parabens; solid phase extraction; ultraviolet filters; water samples; TANDEM MASS-SPECTROMETRY; LIQUID-LIQUID MICROEXTRACTION; ORGANIC UV-FILTERS; ULTRAVIOLET FILTERS; WASTE-WATER; ENVIRONMENTAL WATERS; SORPTIVE EXTRACTION; SAMPLE PREPARATION; CHROMATOGRAPHY; PARABENS;
D O I
10.1002/jssc.201901148
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A silica-based MCM-41 mesoporous material functionalized with cyanopropyl groups has been synthesized by cocondensation, characterized and applied to preconcentrate six parabens and three UV filters in river and swimming-pool waters. The analytes were quantified by ultra-high performance liquid chromatography-tandem mass spectrometry, according to the Directive 96/23/EC. Even though matrix effect was negligible, quantification in river water samples with the standard addition approach improved the recoveries obtained using solvent-based and even with matrixmatched calibration. The method quantification limits in river water samples were 0.05 ng/mL for 2,4-dihydroxybenzophenone and 0.01 ng/mL for the rest. Recoveries, evaluated for a concentration level of 0.5 ng/L, were in the range 93.5-107.6% for parabens and in the range 64.2-85.8% for UV filters, with relative standard deviations intraday <= 10.2 and 10.8%, respectively. This parameter, evaluated for a concentration level of 0.1 ng/L, ranged between 98.3 and 110.4% for parabens and between 61.9 and 89.9% for UV filters, with relative standard deviation intraday <= 15.3 and 15.5%, respectively. The two UV filters with lower recoveries were the most affected by the addition of sodium chloride. River and swimming pool waters were analyzed and all the personal care products were found in the swimming pool water, whereas only methylparaben was detected in the river water.
引用
收藏
页码:2142 / 2153
页数:12
相关论文
共 55 条
  • [1] Occurrence and analysis of parabens in municipal sewage sludge from wastewater treatment plants in Madrid (Spain)
    Albero, Beatriz
    Ana Perez, Rosa
    Sanchez-Brunete, Consuelo
    Luis Tadeo, Jose
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2012, 239 : 48 - 55
  • [2] Determination of trace levels of parabens in real matrices by bar adsorptive microextraction using selective sorbent phases
    Almeida, C.
    Nogueira, J. M. F.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2014, 1348 : 17 - 26
  • [3] HPLC determination of pKa of parabens and investigation on their lipophilicity parameters
    Angelov, T.
    Vlasenko, A.
    Tashkov, W.
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2008, 31 (02) : 188 - 197
  • [4] [Anonymous], 2014, The Fitness for Purpose of Analytical Methods: A Laboratory Guide to Method Validation and Related Topics, V2nd
  • [5] Magnetic nanoparticles coated with ionic liquid for the extraction of endocrine disrupting compounds from waters
    Antonio Casado-Carmona, Francisco
    del Carmen Alcudia-Leon, Maria
    Lucena, Rafael
    Cardenas, Soledad
    Valcarcel, Miguel
    [J]. MICROCHEMICAL JOURNAL, 2016, 128 : 347 - 353
  • [6] New developments in the extraction and determination of parabens in cosmetics and environmental samples. A review
    Antonio Ocana-Gonazlez, Juan
    Villar-Navarro, Mercedes
    Ramos-Payan, Maria
    Fernandez-Torres, Rut
    Angel Bello-Lopez, Miguel
    [J]. ANALYTICA CHIMICA ACTA, 2015, 858 : 1 - 15
  • [7] Stir bar sorptive extraction and liquid chromatography-tandem mass spectrometry determination of polar and non-polar emerging and priority pollutants in environmental waters
    Aparicio, Irene
    Martin, Julia
    Luis Santos, Juan
    Luis Malvar, Jose
    Alonso, Esteban
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2017, 1500 : 43 - 52
  • [8] Electroplating of nanostructured polyaniline-polypyrrole composite coating in a stainless-steel tube for on-line in-tube solid phase microextraction
    Asiabi, Hamid
    Yamini, Yadollah
    Seidi, Shahram
    Esrafili, Ali
    Rezaei, Fatemeh
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1397 : 19 - 26
  • [9] Chemometric optimization of the extraction and derivatization of parabens for their determination in water samples by rotating-disk sorptive extraction and gas chromatography mass spectrometry
    Becerra-Herrera, Mercedes
    Miranda, Valentina
    Arismendi, Daniel
    Richter, Pablo
    [J]. TALANTA, 2018, 176 : 551 - 557
  • [10] A review of personal care products in the aquatic environment: Environmental concentrations and toxicity
    Brausch, John M.