机构:
Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, BelgiumCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
Van Ammel, R.
[1
]
Pomme, S.
论文数: 0引用数: 0
h-index: 0
机构:
Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, BelgiumCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
Pomme, S.
[1
]
Paepen, J.
论文数: 0引用数: 0
h-index: 0
机构:
Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, BelgiumCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
Paepen, J.
[1
]
Sibbens, G.
论文数: 0引用数: 0
h-index: 0
机构:
Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, BelgiumCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
Sibbens, G.
[1
]
机构:
[1] Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
The half-life of Cd-109 was measured by following the decay of sources from a radiochemically pure solution with two different measuring systems: an ionisation chamber and a high-purity germanium (HPGe) detector. The measurements were performed over a period of 3.6 years, i.e. about 2.8 half-lives of Cd-109. The resulting half-life values and detailed uncertainty budgets (k=1) are presented for both systems. The result obtained with the ionisation chamber. 462.36 (33) days, and the one obtained with the HPGe detector, 461.92 (76) days, are mutually consistent. The weighted mean of our measured values. T-1/2(Cd-109)= 462.29 (30)days. is consistent with the currently recommended values of 461.4 (12) days (Schonfeld and Dersch, 2004; IAEA, 2007) and 462.0 (3) days (Xiaolong et al., 2010). From a set of selected experimental values published after 1970. a "partially weighted mean" (Pomme and Spasova, 2008) of T-1/2(Cd-109)=462.36 (39) days was calculated. More measurements are needed to resolve the discrepancies among literature data and to reduce the final uncertainty on the Cd-109 half-life. (C) 2011 Elsevier Ltd. All rights reserved.
机构:
Natl Time Serv Ctr, Lintong 710600, Peoples R China
Univ Chinese Acad Sci, Beijing 100088, Peoples R ChinaNatl Time Serv Ctr, Lintong 710600, Peoples R China
Lu, Benquan
Lu, Xiaotong
论文数: 0引用数: 0
h-index: 0
机构:
Natl Time Serv Ctr, Lintong 710600, Peoples R China
Univ Chinese Acad Sci, Beijing 100088, Peoples R ChinaNatl Time Serv Ctr, Lintong 710600, Peoples R China
Lu, Xiaotong
Wang, Tao
论文数: 0引用数: 0
h-index: 0
机构:
Chongqing Univ, Dept Phys, Chongqing 401331, Peoples R China
Chongqing Univ, Ctr Quantum Mat & Devices, Chongqing 401331, Peoples R China
Chongqing Univ Liyang, Ctr Modern Phys, Inst Smart City, Liyang 213300, Peoples R ChinaNatl Time Serv Ctr, Lintong 710600, Peoples R China
Wang, Tao
Chang, Hong
论文数: 0引用数: 0
h-index: 0
机构:
Natl Time Serv Ctr, Lintong 710600, Peoples R China
Univ Chinese Acad Sci, Beijing 100088, Peoples R ChinaNatl Time Serv Ctr, Lintong 710600, Peoples R China