First phase-contrast tomography with thermal neutrons

被引:19
作者
Dubus, F [1 ]
Bonse, U
Zawisky, M
Baron, M
Loidl, R
机构
[1] Inst Laue Langevin, F-38000 Grenoble, France
[2] Univ Dortmund, Inst Phys, D-44227 Dortmund, Germany
[3] Univ Vienna, Atominst, A-1020 Vienna, Austria
关键词
interferometric imaging; isotopic distributions; neutron interferometry; neutron phase-contrast tomography;
D O I
10.1109/TNS.2005.844319
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Attenuation-contrast tomography with monochromatic thermal neutrons becomes a standard tool at many places in the world. A new tomographic neutron technique-the inter-ferometric imaging or neutron phase-contrast tomography (nPCT)-is introduced. nPCT is similar to x-ray phase-contrast tomography (xPCT) and offers a complete three-dimensional (3-D) investigation of the attenuation, the small angle scattering, and the phase-shifting properties of isotope distributions in the sample. As a first demonstration of the feasibility of nPCT, an aluminum screw has been imaged in an aluminum block of slightly different composition. A spatial resolution of 100 mu m has been achieved and the high sensitivity of phase-contrast measurements with thermal neutrons was verified.
引用
收藏
页码:364 / 370
页数:7
相关论文
共 24 条
  • [1] SPHERICAL-WAVE THEORY OF ZERO-ABSORPTION LLL X-RAY OR NEUTRON INTERFEROMETER
    BAUSPIESS, W
    BONSE, U
    GRAEFF, W
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1976, 9 (APR1) : 68 - 80
  • [2] TEST MEASUREMENTS WITH A PERFECT CRYSTAL NEUTRON INTERFEROMETER
    BAUSPIESS, W
    BONSE, U
    RAUCH, H
    TREIMER, W
    [J]. ZEITSCHRIFT FUR PHYSIK, 1974, 271 (02): : 177 - 182
  • [3] Becker P, 2001, CRYST RES TECHNOL, V36, P589, DOI 10.1002/1521-4079(200107)36:6<589::AID-CRAT589>3.0.CO
  • [4] 2-S
  • [5] BECKMAN F, 1995, SYLAN ANN REP 2, P691
  • [6] Three-dimensional imaging of nerve tissue by x-ray phase-contrast microtomography
    Beckmann, F
    Heise, K
    Kölsch, B
    Bonse, U
    Rajewsky, MF
    Bartscher, M
    Biermann, T
    [J]. BIOPHYSICAL JOURNAL, 1999, 76 (01) : 98 - 102
  • [7] X-ray microtomography (mu CT) using phase contrast for the investigation of organic matter
    Beckmann, F
    Bonse, U
    Busch, F
    Gunnewig, O
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (04) : 539 - 553
  • [8] AN X-RAY INTERFEROMETER WITH LONG SEPARATED INTERFERING BEAM PATHS (E)
    BONSE, U
    HART, M
    [J]. APPLIED PHYSICS LETTERS, 1965, 7 (04) : 99 - &
  • [9] Bonse U., 1977, X-ray optics. Applications to solids, P93
  • [10] BONSE U, 1979, NEUTRON INTERFEROMET