First phase-contrast tomography with thermal neutrons

被引:19
作者
Dubus, F [1 ]
Bonse, U
Zawisky, M
Baron, M
Loidl, R
机构
[1] Inst Laue Langevin, F-38000 Grenoble, France
[2] Univ Dortmund, Inst Phys, D-44227 Dortmund, Germany
[3] Univ Vienna, Atominst, A-1020 Vienna, Austria
关键词
interferometric imaging; isotopic distributions; neutron interferometry; neutron phase-contrast tomography;
D O I
10.1109/TNS.2005.844319
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Attenuation-contrast tomography with monochromatic thermal neutrons becomes a standard tool at many places in the world. A new tomographic neutron technique-the inter-ferometric imaging or neutron phase-contrast tomography (nPCT)-is introduced. nPCT is similar to x-ray phase-contrast tomography (xPCT) and offers a complete three-dimensional (3-D) investigation of the attenuation, the small angle scattering, and the phase-shifting properties of isotope distributions in the sample. As a first demonstration of the feasibility of nPCT, an aluminum screw has been imaged in an aluminum block of slightly different composition. A spatial resolution of 100 mu m has been achieved and the high sensitivity of phase-contrast measurements with thermal neutrons was verified.
引用
收藏
页码:364 / 370
页数:7
相关论文
共 24 条
[1]   SPHERICAL-WAVE THEORY OF ZERO-ABSORPTION LLL X-RAY OR NEUTRON INTERFEROMETER [J].
BAUSPIESS, W ;
BONSE, U ;
GRAEFF, W .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1976, 9 (APR1) :68-80
[2]   TEST MEASUREMENTS WITH A PERFECT CRYSTAL NEUTRON INTERFEROMETER [J].
BAUSPIESS, W ;
BONSE, U ;
RAUCH, H ;
TREIMER, W .
ZEITSCHRIFT FUR PHYSIK, 1974, 271 (02) :177-182
[3]  
Becker P, 2001, CRYST RES TECHNOL, V36, P589, DOI 10.1002/1521-4079(200107)36:6<589::AID-CRAT589>3.0.CO
[4]  
2-S
[5]  
BECKMAN F, 1995, SYLAN ANN REP 2, P691
[6]   Three-dimensional imaging of nerve tissue by x-ray phase-contrast microtomography [J].
Beckmann, F ;
Heise, K ;
Kölsch, B ;
Bonse, U ;
Rajewsky, MF ;
Bartscher, M ;
Biermann, T .
BIOPHYSICAL JOURNAL, 1999, 76 (01) :98-102
[7]   X-ray microtomography (mu CT) using phase contrast for the investigation of organic matter [J].
Beckmann, F ;
Bonse, U ;
Busch, F ;
Gunnewig, O .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (04) :539-553
[8]   AN X-RAY INTERFEROMETER WITH LONG SEPARATED INTERFERING BEAM PATHS (E) [J].
BONSE, U ;
HART, M .
APPLIED PHYSICS LETTERS, 1965, 7 (04) :99-&
[9]  
Bonse U., 1977, X-ray optics. Applications to solids, P93
[10]  
BONSE U, 1979, NEUTRON INTERFEROMET