Respiratory Rate Detection by Empirical Mode Decomposition Method Applied to Diaphragm Mechanomyographic Signals

被引:0
|
作者
Estrada, Luis [1 ,2 ]
Torres, Abel [1 ,2 ]
Sarlabous, Leonardo [2 ]
Fiz, Jose A. [2 ,3 ,4 ]
Jane, Raimon [1 ,2 ]
机构
[1] Univ Politecn Cataluna, Inst Bioengn Catalunya IBEC, E-08028 Barcelona, Spain
[2] Biomed Res Networking Ctr Bioengn Biomat & Nanome, Barcelona 08028, Spain
[3] Hosp Badalona Germans Trias & Pujol, Barcelona, Spain
[4] IBEC, Bangkok, Thailand
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Non-invasive evaluation of respiratory activity is an area of increasing research interest, resulting in the appearance of new monitoring techniques, ones of these being based on the analysis of the diaphragm mechanomyographic (MMGdi) signal. The MMGdi signal can be decomposed into two parts: (1) a high frequency activity corresponding to lateral vibration of respiratory muscles, and (2) a low frequency activity related to excursion of the thoracic cage. The purpose of this study was to apply the empirical mode decomposition (EMD) method to obtain the low frequency of MMGdi signal and selecting the intrinsic mode functions related to the respiratory movement. With this intention, MMGdi signals were acquired from a healthy subject, during an incremental load respiratory test, by means of two capacitive accelerometers located at left and right sides of rib cage. Subsequently, both signals were combined to obtain a new signal which contains the contribution of both sides of thoracic cage. Respiratory rate (RR) measured from the mechanical activity (RRMMG) was compared with that measured from inspiratory pressure signal (RRP). Results showed a Pearson's correlation coefficient (r = 0.87) and a good agreement (mean bias = -0.21 with lower and upper limits of -2.33 and 1.89 breaths per minute, respectively) between RRMMG and RRP measurements. In conclusion, this study suggests that RR can be estimated using EMD for extracting respiratory movement from low mechanical activity, during an inspiratory test protocol.
引用
收藏
页码:3204 / 3207
页数:4
相关论文
共 50 条
  • [31] An efficient method for analysis of EMG signals using improved empirical mode decomposition
    Mishra, Vipin K.
    Bajaj, Varun
    Kumar, Anil
    Sharma, Dheeraj
    Singh, G. K.
    AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 2017, 72 : 200 - 209
  • [32] Towards estimation of respiratory muscle effort with respiratory inductance plethysmography signals and complementary ensemble empirical mode decomposition
    Ya-Chen Chen
    Tzu-Chien Hsiao
    Medical & Biological Engineering & Computing, 2018, 56 : 1293 - 1303
  • [33] Towards estimation of respiratory muscle effort with respiratory inductance plethysmography signals and complementary ensemble empirical mode decomposition
    Chen, Ya-Chen
    Hsiao, Tzu-Chien
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (07) : 1293 - 1303
  • [34] Empirical Modal Decomposition applied to cardiac signals analysis
    Beya, O.
    Jalil, B.
    Fauvet, E.
    Laligant, O.
    WAVELET APPLICATIONS IN INDUSTRIAL PROCESSING VII, 2010, 7535
  • [35] Empirical Mode Decomposition for Saliency Detection
    Rudinac, Maja
    Lenseigne, Boris
    Jonker, Pieter P.
    PROCEEDINGS OF THE FOURTEENTH INTERNATIONAL CONFERENCE ON GENETIC AND EVOLUTIONARY COMPUTATION COMPANION (GECCO'12), 2012, : 365 - 368
  • [36] The empirical mode decomposition and the discrete wavelet transform for detection of human cataract in ultrasound signals
    Janusauskas, A
    Jurkonis, R
    Lukosevicius, A
    INFORMATICA, 2005, 16 (04) : 541 - 556
  • [37] Automatic Expansion of Voltage Signals Using Empirical Mode Decomposition for Voltage Sag Detection
    Li, Heyang
    Meng, Chao
    Zhao, Yingru
    IEEE ACCESS, 2022, 10 : 80138 - 80150
  • [38] Detection of Sleep Apnea from Multiparameter Monitor Signals using Empirical Mode Decomposition
    Madhav, K. Venu
    Krishna, E. Hari
    Reddy, K. Ashoka
    2017 INTERNATIONAL CONFERENCE ON COMPUTER, COMMUNICATION AND SIGNAL PROCESSING (ICCCSP), 2017, : 195 - 200
  • [39] Detection technique of muscle activation intervals for sEMG signals based on the Empirical Mode Decomposition
    Lee, Junghoon
    Ko, Hyunchul
    Lee, Seunghwan
    Lee, Hyunsook
    Yoon, Youngro
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 336 - +
  • [40] Liquid opacity detection method based on Bidimensional Empirical Mode Decomposition
    Guo Qiang
    Song Wenming
    2013 THIRD INTERNATIONAL CONFERENCE ON INSTRUMENTATION & MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2013, : 1247 - 1252