The Myeloid U937 Skin Sensitization Test (U-SENS) addresses the activation of dendritic cell event in the adverse outcome pathway for skin sensitization

被引:191
作者
Piroird, Cecile [1 ]
Ovigne, Jean-Marc [1 ]
Rousset, Francoise [1 ]
Martinozzi-Teissier, Silvia [1 ]
Gomes, Charles [1 ]
Cotovio, Jose [1 ]
Alepee, Nathalie [1 ]
机构
[1] LOreal Res & Innovat, F-93600 Aulnay Sous Bois, France
关键词
Skin sensitization; Dendritic cells; CD86; induction; MUSST; U-SENS (TM); Predictivity; LYMPH-NODE ASSAY; TEST H-CLAT; IN-VITRO; PEPTIDE REACTIVITY; CONTACT ALLERGENS; RISK-ASSESSMENT; END-POINTS; PREDICTION; POTENCY; LINE;
D O I
10.1016/j.tiv.2015.03.009
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
The U-SENS(TM) assay, formerly known as MUSST (Myeloid U937 Skin Sensitization Test), is an in vitro method to assess skin sensitization. Dendritic cell activation following exposure to sensitizers was modelled in the U937 human myeloid cell line by measuring the induction of the expression of CD86 by flow cytometry. The predictive performance of U-SENS(TM) was assessed via a comprehensive comparison analysis with the available human and LLNA data of 175 substances. U-SENS(TM) showed 79% specificity, 90% sensitivity and 88% accuracy. A four laboratory ring study demonstrated the transferability, reliability and reproducibility of U-SENS(TM), with a reproducibility of 95% within laboratories and 79% between-laboratories, showing that the U-SENS(TM) assay is a promising tool in a skin sensitization risk assessment testing strategy. (C) 2015 Published by Elsevier Ltd.
引用
收藏
页码:901 / 916
页数:16
相关论文
共 60 条
[11]  
[Anonymous], JRC SCI POL REP
[12]  
[Anonymous], 2011, GLOB HARM SYST CLASS
[13]  
[Anonymous], NIH PUBLICATION
[14]  
[Anonymous], J APPL TOXICOL
[15]  
[Anonymous], REGUL TOXIC IN PRESS
[16]  
[Anonymous], J APPL TOXICOL
[17]   Dermal sensitization quantitative risk assessment (QRA) for fragrance ingredients [J].
Api, Anne Marie ;
Basketter, David A. ;
Cadby, Peter A. ;
Cano, Marie-France ;
Ellis, Graham ;
Gerberick, G. Frank ;
Griem, Peter ;
McNamee, Pauline M. ;
Ryan, Cindy A. ;
Safford, Robert .
REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2008, 52 (01) :3-23
[18]   Mechanistic applicability domains for nonanimal-based prediction of toxicological end points: General principles and application to reactive toxicity [J].
Aptula, Aynur O. ;
Roberts, David W. .
CHEMICAL RESEARCH IN TOXICOLOGY, 2006, 19 (08) :1097-1105
[19]   The Respiratory Local Lymph Node Assay as a Tool to Study Respiratory Sensitizers [J].
Arts, Josje H. E. ;
de Jong, Wim H. ;
van Triel, Jos J. ;
Schijf, Marcel A. ;
de Klerk, Arja ;
van Loveren, Henk ;
Kuper, C. Frieke .
TOXICOLOGICAL SCIENCES, 2008, 106 (02) :423-434
[20]   Development of an in vitro skin sensitization test using human cell lines: The human Cell Line Activation Test (h-CLAT) I. Optimization of the h-CLAT protocol [J].
Ashikaga, T ;
Yoshida, Y ;
Hirota, M ;
Yoneyama, K ;
Itagaki, H ;
Sakaguchi, H ;
Miyazawa, M ;
Ito, Y ;
Suzuki, H ;
Toyoda, H .
TOXICOLOGY IN VITRO, 2006, 20 (05) :767-773