A new endoscopic posterior cruciate ligament reconstruction: Minimization of graft angulation

被引:29
作者
Ohkoshi, Y [1 ]
Nagasaki, S [1 ]
Yamamoto, K [1 ]
Urushibara, M [1 ]
Tada, H [1 ]
Shigenobu, K [1 ]
Hashimoto, T [1 ]
Yamane, S [1 ]
机构
[1] Hakodate Cent Gen Hosp, Dept Orthopaed Surg, Hakodate, Hokkaido 0408585, Japan
来源
ARTHROSCOPY | 2001年 / 17卷 / 03期
关键词
knee; PCL; arthroscopy; endoscopic surgery; graft angulation; bone tunnel;
D O I
10.1053/jars.2001.21801
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this report is to present a new surgical technique for endoscopic posterior cruciate ligament (PCL) reconstruction and to elucidate the preliminary results. Surgical Technique: The concept of this surgical technique is to minimize the graft angulation at the inner edge of the bone tunnel. The tibial entry point of the guide pin is under the tibial lateral subcondylar flare approximately 1 to 2 cm anterior to the posterior cortex and 4 cm distal to the joint surface. This creates less graft angulation on the posterior aspect of the tibia. A new drill system has been devised to allow antegrade femoral drilling starting from inside the notch. This method also allows better femoral tunnel orientation. As a substitute graft material, we use autogenous hamstring tendons, and we secure them with an EndoButton (Smith & Nephew, Mansfield, MA) and post screw. Methods: Since 1995, 30 knees have undergone endoscopic PCL reconstruction. Twenty-one patients were evaluated after a minimum follow-up of 1 year (17.9 +/- 7.7 mo). The clinical evaluation was performed using the International Knee Documentation Committee (IKDC) form. Results: The range of motion was rated as A for 17 cases, B in 3 cases, and C in one case. The total anteroposterior translation (KT-1000, manual-maximum) showed a range of 1.0 to 5.5 mm (mean, 3.8 mm). The ratings of the ligament examination were A in 9 cases and B in 1? cases. The final IKDC evaluation was A (normal) in 3 cases, B (nearly normal) in 17 cases, and C (abnormal) in 1 case. Conclusions: A good clinical outcome was achieved with our endoscopic PCL reconstruction. The reduction of the graft angulation may contribute to the good results for PCL reconstruction.
引用
收藏
页码:258 / 263
页数:6
相关论文
共 11 条
[1]  
[Anonymous], ALL INSIDE ACL RECON
[2]   POSTERIOR CRUCIATE LIGAMENT TIBIAL INLAY RECONSTRUCTION [J].
BERG, EE .
ARTHROSCOPY, 1995, 11 (01) :69-76
[3]   Evaluation and treatment of posterior cruciate ligament injuries [J].
Harner, CD ;
Hoher, J .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1998, 26 (03) :471-482
[4]   ARTHROSCOPIC INTRAARTICULAR INTERFERENCE SCREW TECHNIQUE OF POSTERIOR CRUCIATE LIGAMENT RECONSTRUCTION - ONE-INCISION TECHNIQUE [J].
KIM, SJ ;
MIN, BH .
ARTHROSCOPY, 1994, 10 (03) :319-323
[5]   BIOMECHANICAL ANALYSIS OF REHABILITATION IN THE STANDING POSITION [J].
OHKOSHI, Y ;
YASUDA, K ;
KANEDA, K ;
WADA, T ;
YAMANAKA, M .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1991, 19 (06) :605-611
[6]   Changes in muscle strength properties caused by harvesting of autogenous semitendinosus tendon for reconstruction of contralateral anterior cruciate ligament [J].
Ohkoshi, Y ;
Inoue, C ;
Yamane, S ;
Hashimoto, T ;
Ishida, R .
ARTHROSCOPY, 1998, 14 (06) :580-584
[7]   The effect of cryotherapy on intraarticular temperature and postoperative care after anterior cruciate ligament reconstruction [J].
Ohkoshi, Y ;
Ohkoshi, M ;
Nagasaki, S ;
Ono, A ;
Hashimoto, T ;
Yamane, S .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (03) :357-362
[8]  
RAASCH WG, 1999, SPECIALTY DAY PROGRA, P58
[9]  
ROSENBERG TD, ENDOSCOPIC TECHNIQUE
[10]   Arthroscopic posterior cruciate ligament reconstruction using hamstring tendons: One-incision technique with EndoButton [J].
Shino, K ;
Nakagawa, S ;
Nakamura, N ;
Matsumoto, N ;
Toritsuka, Y ;
Natsuume, T .
ARTHROSCOPY, 1996, 12 (05) :638-642