Postcolumn reactor using a laser-drilled capillary for light-emitting diode-induced fluorescence detection in CE

被引:11
作者
Yamamoto, Daisuke
Kaneta, Takashi
Imasaka, Totaro [1 ]
机构
[1] Kyushu Univ, Grad Sch Engn, Dept Appl Chem, Fukuoka 8190395, Japan
[2] Kyushu Univ, Ctr Future Chem, Div Translat Res, Fukuoka 8190395, Japan
关键词
amino acid; derivatization; light-emitting diode; o-phthaidialdehyde; postcolumn;
D O I
10.1002/elps.200700274
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study investigated a novel postcolumn reactor for fluorescence detection in CE. A laser-drilled capillary, with an aperture made by laser ablation, was used for mixing derivatization reagents with the analytes separated by CZE. The derivatization reagents, o-phthaldialdehyde (OPA), and 2-mercaptoethanol, were introduced into the capillary through the aperture and reacted with the analytes after CZE separation. High voltages were applied to both the inlet reservoir and the reservoir filled with the derivatization reagents. Thus, the flow rate of the derivatization reagents was controlled by the electric potential that was applied to the reservoir of the derivatization reagents. A UV light-emitting diode was used as an excitation light source for the fluorescence detection of OPA derivatives. A commercially available tee connector was compared with the laser-drilled capillary. The results implied that the dead volume of the laser-drilled capillary was less than that of the tee connector since the laser-drilled capillary suppressed band broadening more efficiently. The LODs for amino acids were determined to be similar to 5 mu M. The method was applied to the determination of amino acids in a Japanese beverage.
引用
收藏
页码:4143 / 4149
页数:7
相关论文
共 23 条
  • [1] FLUORESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS - EVALUATION OF DERIVATIZING REAGENTS AND TECHNIQUES
    ALBIN, M
    WEINBERGER, R
    SAPP, E
    MORING, S
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (05) : 417 - 422
  • [2] Pre-, on- and post-column derivatization in capillary electrophoresis
    Bardelmeijer, HA
    Waterval, JCM
    Lingeman, H
    van't Hof, R
    Bult, A
    Underberg, WJM
    [J]. ELECTROPHORESIS, 1997, 18 (12-13) : 2214 - 2227
  • [3] THE PIGTAILING APPROACH TO OPTICAL-DETECTION IN CAPILLARY ELECTROPHORESIS
    BRUNO, AE
    MAYSTRE, F
    KRATTIGER, B
    NUSSBAUM, P
    GASSMANN, E
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (05) : 190 - 198
  • [4] Capillary electrophoresis with a UV light-emitting diode source for chemical monitoring of native and derivatized fluorescent compounds
    Hapuarachchi, Suminda
    Janaway, Gordon A.
    Aspinwall, Craig A.
    [J]. ELECTROPHORESIS, 2006, 27 (20) : 4052 - 4059
  • [5] Hadamard transform capillary electrophoresis combined with absorption spectrometry
    Hata, K
    Kaneta, T
    Imasaka, T
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (15) : 4421 - 4425
  • [6] Hillebrand S, 2002, ELECTROPHORESIS, V23, P2445, DOI 10.1002/1522-2683(200208)23:15<2445::AID-ELPS2445>3.0.CO
  • [7] 2-K
  • [8] Diode lasers in analytical chemistry
    Imasaka, T
    [J]. TALANTA, 1999, 48 (02) : 305 - 320
  • [9] SEMICONDUCTOR-LASER SPECTROMETRY
    IMASAKA, T
    [J]. ANALYTICAL SCIENCES, 1993, 9 (03) : 329 - 344
  • [10] MICROCHIP CAPILLARY ELECTROPHORESIS WITH AN INTEGRATED POSTCOLUMN REACTOR
    JACOBSON, SC
    KOUTNY, LB
    HERGENRODER, R
    MOORE, AW
    RAMSEY, JM
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (20) : 3472 - 3476