摘要
Low-analysis fertilizer composition highly poses risk to soil infertility, crop yield and farmer livelihood. Fertilizer testing via traditional laboratory methods is a tool for quality control but with the significantly high cost of investment and maintenance in the long run. Physiochemical data from vibrational spectra obtained from the near-infrared reflectance (NIR) analyzer shows successful installation design for real-time quality monitoring of compound fertilizer production in this study overcoming exhaustive laboratory methods offering competitive advantages to the fertilizer industry becoming a great tool for product development and lower the risk of farmers buying the low-analysis fertilizer. The NIR analyzer was designed for on-line analysis of nutrient contents of the fertilizer before bagging. Total nitrogen (TN%), available phosphorus (available P2O5%), water-soluble potassium (water-soluble K2O%), total organic matter (TOM%), moisture content (TMC%) including pH were required to be monitored to ensure final product release being within limits legislatively established. Spectral variations across different times of measurement over a day of the production was investigated in the condition of on-line system instead of a controlled condition to confirm the measurement will be reliable and in good reproducibility. Calibration models were developed using Partial Least Squares (PLS) regression with a series of data pretreatments on individual model per nutrient. Precision and accuracy figures of NIR results were obtained considerably good enough to the manufacturing practice. NIR prediction results were later designed for threshold and feed-back to the process control.
引用
收藏
页数:9
相关论文
共 39 条
[1]  
[Anonymous], 2002, A User-Friendly Guide to Multivariate Calibration and Classification
[2]   STANDARD NORMAL VARIATE TRANSFORMATION AND DE-TRENDING OF NEAR-INFRARED DIFFUSE REFLECTANCE SPECTRA [J].
BARNES, RJ ;
DHANOA, MS ;
LISTER, SJ .
APPLIED SPECTROSCOPY, 1989, 43 (05) :772-777
[3]   Near-infrared reflectance spectroscopy as a method to predict chemical composition of breast meat and discriminate between different n-3 feeding sources [J].
Berzaghi, P ;
Dalla Zotte, A ;
Jansson, LM ;
Andrighetto, I .
POULTRY SCIENCE, 2005, 84 (01) :128-136
[4]  
Dickens J.E., 2010, OVERVIEW PROCESS ANA, P1
[5]   On the numerical stability of two widely used PLS algorithms [J].
Faber, Nicolaas M. ;
Ferre, Joan .
JOURNAL OF CHEMOMETRICS, 2008, 22 (1-2) :101-105
[6]   LINEARIZATION AND SCATTER-CORRECTION FOR NEAR-INFRARED REFLECTANCE SPECTRA OF MEAT [J].
GELADI, P ;
MACDOUGALL, D ;
MARTENS, H .
APPLIED SPECTROSCOPY, 1985, 39 (03) :491-500
[7]   Fast Determination of Contents of Nutrients and Stone Powder in Compound Fertilizer Using Near Infrared Diffuse Reflectance Spectroscopy [J].
Guo Zheng ;
Yuan Hong-fu ;
Zhang Xian ;
Song Chun-feng ;
Li Xiao-yu ;
Xe Jin-chun .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2011, 31 (06) :1521-1523
[8]   Temporal and environmental sensitivity of a photodiode array spectrophometric system [J].
Hayes, Clinton John ;
Greensill, Colin Victor ;
Walsh, Kerry Brian .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2014, 22 (04) :297-304
[9]   In-line analysis of ground beef using a diode array near infrared instrument on a conveyor belt [J].
Hildrum, KI ;
Nilson, BN ;
Westad, F ;
Wahlgren, NM .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2004, 12 (06) :367-376
[10]   Near infrared spectroscopy for on/in-line monitoring of quality in foods and beverages: A review [J].
Huang, Haibo ;
Yu, Haiyan ;
Xu, Huirong ;
Ying, Yibin .
JOURNAL OF FOOD ENGINEERING, 2008, 87 (03) :303-313