Comparison of lesion characteristics between conventional and high-power short-duration ablation using contact force-sensing catheter in patients with paroxysmal atrial fibrillation

被引:6
|
作者
Chen, Chun-Chao [1 ,2 ,3 ,4 ]
Lee, Po-Tseng [1 ,5 ]
Vu Van Ba [1 ,6 ]
Chuang, Chieh-Mao [1 ,7 ]
Lin, Yenn-Jiang [1 ,8 ]
Lo, Li-Wei [1 ,8 ]
Hu, Yu-Feng [1 ,8 ]
Chung, Fa-Po [1 ,8 ]
Lin, Chin-Yu [1 ,8 ]
Chang, Ting-Yung [1 ,8 ]
Vicera, Jennifer Jeanne [1 ,9 ]
Huang, Ting-Chun [1 ,5 ]
Liu, Chih-Min [1 ,8 ]
Wu, Cheng-, I [1 ,8 ]
Lugtu, Isaiah C. [1 ,10 ]
Jain, Ankit [1 ,11 ,12 ]
Chang, Shih-Lin [1 ,4 ]
Chen, Shih-Ann [1 ,8 ,13 ]
机构
[1] Taipei Vet Gen Hosp, Heart Rhythm Ctr, Dept Med, Div Cardiol, 201 Sec 2,Shih Pai Rd, Taipei, Taiwan
[2] Taipei Med Univ, Shuang Ho Hosp, Dept Internal Med, Div Cardiol, New Taipei, Taiwan
[3] Taipei Med Univ, Taipei Heart Inst, Taipei, Taiwan
[4] Taipei Med Univ, Coll Med, Sch Med, Div Cardiol,Dept Internal Med, Taipei, Taiwan
[5] Natl Cheng Kung Univ Hosp, Dept Internal Med, Div Cardiovasc Med, Tainan, Taiwan
[6] E Hosp, Cardiovasc Ctr, Hanoi, Vietnam
[7] China Med Univ, China Med Univ Childrens Hosp, Div Pediat Cardiol, Taichung, Taiwan
[8] Natl Yang Ming Chiao Tung Univ, Fac Med, Sch Med, Taipei, Taiwan
[9] Univ Santo Tomas Hosp, Dept Med, Sect Cardiol, Manila, Philippines
[10] Chinese Gen Hosp & Med Ctr, Heart Inst, Manila, Philippines
[11] Vardhman Mahavir Med Coll, New Delhi, India
[12] Safdarjang Hosp, New Delhi, India
[13] Taichung Vet Gen Hosp, Cardiovasc Ctr, Taichung, Taiwan
关键词
Atrial fibrillation; Pulmonary vein isolation; Contact force-guided ablation; Voltage; Force time integral; High-power short-duration ablation; PULMONARY VEIN ISOLATION; RADIOFREQUENCY ABLATION; TRANSMURALITY; SAFETY;
D O I
10.1186/s12872-021-02196-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transmural lesion creation is essential for effective atrial fibrillation (AF) ablation. Lesion characteristics between conventional energy and high-power short-duration (HPSD) setting in contact force-guided (CF) ablation for AF remained unclear. Methods Eighty consecutive AF patients who received CF with conventional energy setting (power control: 25-30 W, force-time integral = 400 g s, n = 40) or with HPSD (power control: 40-50 W, 10 s, n = 40) ablation were analyzed. Of them, 15 patients in each conventional and HPSD group were matched by age and gender respectively for ablation lesions analysis. Type A and B lesions were defined as a lesion with and without significant voltage reduction after ablation, respectively. The anatomical distribution of these lesions and ablation outcomes among the 2 groups were analyzed. Results 1615 and 1724 ablation lesions were analyzed in the conventional and HPSD groups, respectively. HPSD group had a higher proportion of type A lesion compared to conventional group (P < 0.01). In the conventional group, most type A lesions were at the right pulmonary vein (RPV) posterior wall (50.2%) whereas in the HPSD group, most type A lesions were at the RPV anterior wall (44.0%) (P = 0.04). The procedure time and ablation time were significantly shorter in the HPSD group than that in the conventional group (91.0 +/- 12.1 vs. 124 +/- 14.2 min, P = 0.03; 30.7 +/- 19.2 vs. 57.8 +/- 21 min, P = 0.02, respectively). At a mean follow-up period of 11 +/- 1.4 months, there were 13 and 7 patients with recurrence in conventional and HPSD group respectively (P = 0.03). Conclusion Optimal ablation lesion characteristics and distribution after conventional and HPSD ablation differed significantly. HPSD ablation had shorter ablation time and lower recurrence rate than did conventional ablation.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] One-year outcomes in patients undergoing very high-power short-duration ablation for atrial fibrillation
    Francesco Solimene
    Teresa Strisciuglio
    Vincenzo Schillaci
    Alberto Arestia
    Gergana Shopova
    Armando Salito
    Giuseppe Bottaro
    Giovanni Marano
    Fernando Coltorti
    Giuseppe Stabile
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 1911 - 1917
  • [32] One-year outcomes in patients undergoing very high-power short-duration ablation for atrial fibrillation
    Solimene, Francesco
    Strisciuglio, Teresa
    Schillaci, Vincenzo
    Arestia, Alberto
    Shopova, Gergana
    Salito, Armando
    Bottaro, Giuseppe
    Marano, Giovanni
    Coltorti, Fernando
    Stabile, Giuseppe
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (08) : 1911 - 1917
  • [33] Characteristics of Esophageal Injury in Ablation of Atrial Fibrillation Using a High-Power Short-Duration Setting
    Kaneshiro, Takashi
    Kamioka, Masashi
    Hijioka, Naoko
    Yamada, Shinya
    Yokokawa, Tetsuro
    Misaka, Tomofumi
    Hikichi, Takuto
    Yoshihisa, Akiomi
    Takeishi, Yasuchika
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2020, 13 (10) : 1124 - 1131
  • [34] High-Power, Short-Duration Ablation under the Guidance of Relatively Low Ablation Index Values for Paroxysmal Atrial Fibrillation: Long-Term Outcomes and Characteristics of Recurrent Atrial Arrhythmias
    Jin, Shuyu
    Lin, Weidong
    Fang, Xianhong
    Liao, Hongtao
    Zhan, Xianzhang
    Fu, Lu
    Jiang, Junrong
    Ye, Xingdong
    Liu, Huiyi
    Chen, Yanlin
    Pu, Sijia
    Wu, Shulin
    Deng, Hai
    Xue, Yumei
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (03)
  • [35] Recovery of Conduction Following High-Power Short-Duration Ablation in Patients With Atrial Fibrillation A Single-Center Experience
    Mohanty, Sanghamitra
    Trivedi, Chintan
    Della Rocca, Domenico G.
    Gianni, Carola
    MacDonald, Bryan
    Quintero Mayedo, Angel
    Al-Ahmad, Amin
    Burkhardt, John D.
    Bassiouny, Mohamed
    Gallinghouse, G. Joseph
    Horton, Rodney
    Di Biase, Luigi
    Natale, Andrea
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2021, 14 (10) : E010096
  • [36] Pulmonary vein isolation for atrial fibrillation using true high-power short-duration vs. cryoballoon ablation
    Woermann, Jonas
    Lueker, Jakob
    van den Bruck, Jan-Hendrik
    Filipovic, Karlo
    Erlhoefer, Susanne
    Scheurlen, Cornelia
    Dittrich, Sebastian
    Schipper, Jan-Hendrik
    Steven, Daniel
    Sultan, Arian
    CLINICAL RESEARCH IN CARDIOLOGY, 2023, 112 (06) : 846 - 852
  • [37] Comparison of very high-power short-duration, high-power short-duration, and low-power long-duration radiofrequency ablation for atrial fibrillation: A systematic review and network meta-analysis
    Junarta, Joey
    Rodriguez, Sebastian
    Ullah, Waqas
    Siddiqui, Muhammad U.
    Riley, Joshua M.
    Patel, Anjani
    O'Neill, Parker
    Dikdan, Sean J.
    Fradin, James J.
    Rosen, Jake L.
    Frisch, Daniel R.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2023, 46 (12): : 1609 - 1634
  • [38] Very High-Power Short-Duration Ablation for Atrial Fibrillation in Adults With Congenital Heart Disease
    Lengauer, Sarah
    Erhard, Nico
    Popa, Miruna A.
    Telishevska, Marta
    Krafft, Hannah
    Bahlke, Fabian
    Englert, Florian
    Bourier, Felix
    Reents, Tilko
    Deisenhofer, Isabel
    Hessling, Gabriele
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2025, : 625 - 631
  • [39] Short and Long-Term Outcomes of Lesion Index-Guided High-Power Short-Duration Approach for Atrial Fibrillation Ablation
    Di Cori, Andrea
    Parollo, Matteo
    Gentile, Francesco
    Pistelli, Lorenzo
    Vitale, Carlo
    Della Volpe, Salvatore
    Santoro, Mario Giannotti
    Mazzocchetti, Lorenzo
    De Lucia, Raffaele
    Canu, Antonio
    Barletta, Valentina
    Grifoni, Gino
    Segreti, Luca
    Bongiorni, Maria Grazia
    Zucchelli, Giulio
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (15)
  • [40] High-power, Short-duration Radiofrequency Ablation of Atrial Fibrillation: Point-by-Point or Catheter Dragging Technique?
    Fenelon, Guilherme
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2025, 121 (12)