Comparison of lesion characteristics between conventional and high-power short-duration ablation using contact force-sensing catheter in patients with paroxysmal atrial fibrillation

被引:6
|
作者
Chen, Chun-Chao [1 ,2 ,3 ,4 ]
Lee, Po-Tseng [1 ,5 ]
Vu Van Ba [1 ,6 ]
Chuang, Chieh-Mao [1 ,7 ]
Lin, Yenn-Jiang [1 ,8 ]
Lo, Li-Wei [1 ,8 ]
Hu, Yu-Feng [1 ,8 ]
Chung, Fa-Po [1 ,8 ]
Lin, Chin-Yu [1 ,8 ]
Chang, Ting-Yung [1 ,8 ]
Vicera, Jennifer Jeanne [1 ,9 ]
Huang, Ting-Chun [1 ,5 ]
Liu, Chih-Min [1 ,8 ]
Wu, Cheng-, I [1 ,8 ]
Lugtu, Isaiah C. [1 ,10 ]
Jain, Ankit [1 ,11 ,12 ]
Chang, Shih-Lin [1 ,4 ]
Chen, Shih-Ann [1 ,8 ,13 ]
机构
[1] Taipei Vet Gen Hosp, Heart Rhythm Ctr, Dept Med, Div Cardiol, 201 Sec 2,Shih Pai Rd, Taipei, Taiwan
[2] Taipei Med Univ, Shuang Ho Hosp, Dept Internal Med, Div Cardiol, New Taipei, Taiwan
[3] Taipei Med Univ, Taipei Heart Inst, Taipei, Taiwan
[4] Taipei Med Univ, Coll Med, Sch Med, Div Cardiol,Dept Internal Med, Taipei, Taiwan
[5] Natl Cheng Kung Univ Hosp, Dept Internal Med, Div Cardiovasc Med, Tainan, Taiwan
[6] E Hosp, Cardiovasc Ctr, Hanoi, Vietnam
[7] China Med Univ, China Med Univ Childrens Hosp, Div Pediat Cardiol, Taichung, Taiwan
[8] Natl Yang Ming Chiao Tung Univ, Fac Med, Sch Med, Taipei, Taiwan
[9] Univ Santo Tomas Hosp, Dept Med, Sect Cardiol, Manila, Philippines
[10] Chinese Gen Hosp & Med Ctr, Heart Inst, Manila, Philippines
[11] Vardhman Mahavir Med Coll, New Delhi, India
[12] Safdarjang Hosp, New Delhi, India
[13] Taichung Vet Gen Hosp, Cardiovasc Ctr, Taichung, Taiwan
关键词
Atrial fibrillation; Pulmonary vein isolation; Contact force-guided ablation; Voltage; Force time integral; High-power short-duration ablation; PULMONARY VEIN ISOLATION; RADIOFREQUENCY ABLATION; TRANSMURALITY; SAFETY;
D O I
10.1186/s12872-021-02196-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transmural lesion creation is essential for effective atrial fibrillation (AF) ablation. Lesion characteristics between conventional energy and high-power short-duration (HPSD) setting in contact force-guided (CF) ablation for AF remained unclear. Methods Eighty consecutive AF patients who received CF with conventional energy setting (power control: 25-30 W, force-time integral = 400 g s, n = 40) or with HPSD (power control: 40-50 W, 10 s, n = 40) ablation were analyzed. Of them, 15 patients in each conventional and HPSD group were matched by age and gender respectively for ablation lesions analysis. Type A and B lesions were defined as a lesion with and without significant voltage reduction after ablation, respectively. The anatomical distribution of these lesions and ablation outcomes among the 2 groups were analyzed. Results 1615 and 1724 ablation lesions were analyzed in the conventional and HPSD groups, respectively. HPSD group had a higher proportion of type A lesion compared to conventional group (P < 0.01). In the conventional group, most type A lesions were at the right pulmonary vein (RPV) posterior wall (50.2%) whereas in the HPSD group, most type A lesions were at the RPV anterior wall (44.0%) (P = 0.04). The procedure time and ablation time were significantly shorter in the HPSD group than that in the conventional group (91.0 +/- 12.1 vs. 124 +/- 14.2 min, P = 0.03; 30.7 +/- 19.2 vs. 57.8 +/- 21 min, P = 0.02, respectively). At a mean follow-up period of 11 +/- 1.4 months, there were 13 and 7 patients with recurrence in conventional and HPSD group respectively (P = 0.03). Conclusion Optimal ablation lesion characteristics and distribution after conventional and HPSD ablation differed significantly. HPSD ablation had shorter ablation time and lower recurrence rate than did conventional ablation.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Effect on sinus cycle length and atrioventricular node function after high-power short-duration versus conventional radiofrequency catheter ablation in paroxysmal atrial fibrillation
    Ungjeong Do
    Minsoo Kim
    Min Soo Cho
    Gi-Byoung Nam
    Kee-Joon Choi
    Jun Kim
    International Journal of Arrhythmia, 23 (1)
  • [22] Meta-Analysis of Pulsed-Field Ablation Versus- High-Power Short-Duration Ablation for Atrial Fibrillation
    Xue, Jun
    Huang, Qunying
    Yu, Fuling
    Mao, Yinjun
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2025, : 180 - 191
  • [23] Contact force and catheter stability are predictive metrics of successful pulmonary vein isolation with high-power short duration ablation in atrial fibrillation
    Honarbakhsh, Shohreh
    Martin, Claire A.
    Dhillon, Gurpreet
    Gallagher, Mark
    Sohal, Manav
    Chow, Anthony
    Ahsan, Syed
    Abbass, Hakam
    Whittaker-Axon, Sarah
    Lambiase, Pier D.
    Davies, Mark J.
    Ginks, Matthew
    Hunter, Ross J.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (05) : 1141 - 1151
  • [24] The evolution of high-power short-duration atrial fibrillation ablation: "The long slog"
    Winkle, Roger A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (02) : 342 - 344
  • [25] Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation
    Cheng, Cheng
    Xu, Banglong
    Sheng, Jianlong
    Huang, Zheng
    He, Fei
    Gao, Feng
    Wang, Xiaochen
    EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2022, 2022
  • [26] Meta-analysis of high-power short-duration versus cryoballoon ablation for atrial fibrillation
    Lin, Limin
    Huang, Ying
    Huang, Qunying
    Yu, Fuling
    Mao, Yinjun
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (08): : 1013 - 1024
  • [27] 50-W vs 40-W During High-Power Short-Duration Ablation for Paroxysmal Atrial Fibrillation
    Costea, Alexandru
    Diaz, Juan Carlos
    Osorio, Jose
    Matos, Carlos D.
    Hoyos, Carolina
    Goyal, Sandeep
    Te, Charles
    D'Souza, Benjamin
    Rastogi, Mohit
    Lopez-Cabanillas, Nestor
    Ibanez, Laura C.
    Thorne, Christopher
    Varley, Allyson L.
    Zei, Paul C.
    Sauer, William H.
    Romero, Jorge E.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (12) : 2573 - 2583
  • [28] Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force-Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial Fibrillation Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) Study
    Reddy, Vivek Y.
    Dukkipati, Srinivas R.
    Neuzil, Petr
    Natale, Andrea
    Albenque, Jean-Paul
    Kautzner, Josef
    Shah, Dipen
    Michaud, Gregory
    Wharton, Marcus
    Harari, David
    Mahapatra, Srijoy
    Lambert, Hendrik
    Mansour, Moussa
    CIRCULATION, 2015, 132 (10) : 907 - 915
  • [29] HPSD ablation for AF high-power short-duration RF ablation for atrial fibrillation: A review
    Winkle, Roger A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (10) : 2813 - 2823
  • [30] Changes and impacts in early recurrences after atrial fibrillation ablation in contact force era: comparison of high-power short-duration with conventional technique-FIRST experience data
    Vassallo, Fabricio
    Meigre, Lucas Luis
    Serpa, Eduardo
    Cunha, Christiano
    Simoes Jr, Aloyr
    Carloni, Hermes
    Amaral, Dalton
    Meira, Karla
    Pezzin, Flavia
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (02) : 363 - 371