Clinical impact of point-of-care vs laboratory measurement of anticoagulation

被引:24
|
作者
Sunderji, R
Gin, K
Shalansky, K
Carter, C
Chambers, K
Davies, C
Schwartz, L
Fung, A
机构
[1] Vancouver Gen Hosp, Pharmaceut Sci CSU, Vancouver, BC V5Z 1M9, Canada
[2] Vancouver Gen Hosp, Unit Cardiol, Vancouver, BC V5Z 1M9, Canada
[3] Vancouver Gen Hosp, Nephrol Unit, Vancouver, BC V5Z 1M9, Canada
[4] Vancouver Gen Hosp, Coronary Care Unit, Vancouver, BC V5Z 1M9, Canada
[5] Vancouver Gen Hosp, Echocardiog Lab, Vancouver, BC V5Z 1M9, Canada
[6] Vancouver Gen Hosp, Dept Lab Med, Vancouver, BC V5Z 1M9, Canada
[7] Vancouver Gen Hosp, Ctr Clin Epidemiol & Evaluat, Vancouver, BC V5Z 1M9, Canada
[8] Vancouver Gen Hosp, Ctr Cardiol, Vancouver, BC V5Z 1M9, Canada
[9] Univ British Columbia, Fac Pharmaceut Sci, Vancouver, BC, Canada
[10] Univ British Columbia, Post Grad Cardiol Training Program, Vancouver, BC, Canada
[11] Univ British Columbia, Fac Med, Vancouver, BC, Canada
[12] Univ British Columbia, Fac Pathol & Lab Med, Vancouver, BC, Canada
[13] Evergreen House, Programs Seniors, N Vancouver, BC, Canada
关键词
point-of-care; self-testing; international normalized ratio; self-management; warfarin; anticoagulation;
D O I
10.1309/P2Y3VM4AXPVUDAW3
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Patients using anticoagulation point-of-care (POC) monitors are advised to periodically test these systems against laboratory methods to monitor performance. The international normalized ratio (INR), however, can vary between test systems owing to different instrument-reagent combinations. In a randomized study evaluating warfarin self-management, we compared INR measured by patients on a POC monitor (ProTime, International Technidyne Corporation, Edison, NJ) with those obtained at a hospital laboratory within 1 hour Ninety-one paired INR determinations from 55 patients met inclusion criteria. Clinical agreement in which POC and laboratory INR were within or outside the target INR range occurred in 56 (62%) of 91 cases (K = 0.35). The mean (SD) difference between POC and laboratory INR was 0.44 (0.61). Six pairs differed by 1 or more INR units, 3 at study initiation resulting in POC monitor replacement. The accuracy of INR self-testing with ProTime was acceptable. The small failure rate of INR agreement might be clinically important, suggesting the need for external quality control systems.
引用
收藏
页码:184 / 188
页数:5
相关论文
共 50 条
  • [31] Electrochemical Disposable Biosensor to Monitor Dabigatran in Point-of-Care Anticoagulation Therapy
    Mruthunjaya, Ashwin K. V.
    Chatelier, Ronald C.
    Torriero, Angel A. J.
    MOLECULES, 2023, 28 (13):
  • [32] Performance of a point-of-care device in determining prothrombin time in an anticoagulation clinic
    Colella, Marina P.
    Fiusa, Maiara M. L.
    Orsi, Fernanda L. A.
    de Paula, Erich V.
    Annichino-Bizzacchi, Joyce M.
    BLOOD COAGULATION & FIBRINOLYSIS, 2012, 23 (02) : 172 - 174
  • [33] Analytical performance of a point-of-care device in monitoring patients on oral anticoagulation with vitamin K antagonists
    Sen, Indrani
    Stephen, Edwin
    Agarwal, Sunil
    Rebekah, Grace
    Nair, Sukesh Chandran
    PHLEBOLOGY, 2016, 31 (09) : 660 - 667
  • [34] Point-of-care prothrombin time measurement for professional and patient self-testing use - A multicenter clinical experience
    Andrew, M
    Ansell, JL
    Becker, DM
    Becker, RC
    Triplett, DA
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2001, 115 (02) : 288 - 296
  • [35] Compact point-of-care system for clinical diagnostics
    Kemmler, Manuel
    Koger, Birgit
    Sulz, Gerd
    Sauer, Ursula
    Schleicher, Erwin
    Preininger, Claudia
    Brandenburg, Albrecht
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (01) : 44 - 51
  • [36] Variation between Point-of-care and Laboratory HbA1c testing in Clinical Practice
    Fellows, Shawn E.
    Cipriano, Gabriela C.
    PUERTO RICO HEALTH SCIENCES JOURNAL, 2019, 38 (03) : 189 - 191
  • [37] Quantitative Measurement of Deformational Plagiocephaly and Brachycephaly at the Point-of-care
    Seifabadi, Reza
    Aalamifar, Fereshteh
    Hezaveh, S. Hossein
    Kocabalkanli, Can
    Linguraru, Marius George
    MEDICAL IMAGING 2021: COMPUTER-AIDED DIAGNOSIS, 2021, 11597
  • [38] Accuracy of the CoaguChek XS for point-of-care international normalized ratio (INR) measurement in children requiring warfarin
    Bauman, Mary E.
    Black, Karina L.
    Massicotte, Mary P.
    Bauman, Michelle L.
    Kuhle, Stefan
    Howlett-Clyne, Susan
    Cembrowski, George S.
    Bajzar, Laszlo
    THROMBOSIS AND HAEMOSTASIS, 2008, 99 (06) : 1097 - 1103
  • [39] Point-of-Care Ultrasound Use, Accuracy, and Impact on Clinical Decision Making in Rwanda Hospitals
    Henwood, Patricia C.
    Mackenzie, David C.
    Liteplo, Andrew S.
    Rempell, Joshua S.
    Murray, Alice F.
    Leo, Megan M.
    Dukundane, Damas
    Dean, Anthony J.
    Rulisa, Stephen
    Noble, Vicki E.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (06) : 1189 - 1194
  • [40] Is perioperative point-of-care prothrombin time testing accurate compared to the standard laboratory test?
    Urwyler, Natalie
    Staub, Lukas R.
    Beran, Dominik
    Deplazes, Marcus
    Lord, Sarah J.
    Alberio, Lorenzo
    Theiler, Lorenz
    Greif, Robert
    THROMBOSIS AND HAEMOSTASIS, 2009, 102 (04) : 779 - 786