Clinical impact of point-of-care vs laboratory measurement of anticoagulation

被引:24
|
作者
Sunderji, R
Gin, K
Shalansky, K
Carter, C
Chambers, K
Davies, C
Schwartz, L
Fung, A
机构
[1] Vancouver Gen Hosp, Pharmaceut Sci CSU, Vancouver, BC V5Z 1M9, Canada
[2] Vancouver Gen Hosp, Unit Cardiol, Vancouver, BC V5Z 1M9, Canada
[3] Vancouver Gen Hosp, Nephrol Unit, Vancouver, BC V5Z 1M9, Canada
[4] Vancouver Gen Hosp, Coronary Care Unit, Vancouver, BC V5Z 1M9, Canada
[5] Vancouver Gen Hosp, Echocardiog Lab, Vancouver, BC V5Z 1M9, Canada
[6] Vancouver Gen Hosp, Dept Lab Med, Vancouver, BC V5Z 1M9, Canada
[7] Vancouver Gen Hosp, Ctr Clin Epidemiol & Evaluat, Vancouver, BC V5Z 1M9, Canada
[8] Vancouver Gen Hosp, Ctr Cardiol, Vancouver, BC V5Z 1M9, Canada
[9] Univ British Columbia, Fac Pharmaceut Sci, Vancouver, BC, Canada
[10] Univ British Columbia, Post Grad Cardiol Training Program, Vancouver, BC, Canada
[11] Univ British Columbia, Fac Med, Vancouver, BC, Canada
[12] Univ British Columbia, Fac Pathol & Lab Med, Vancouver, BC, Canada
[13] Evergreen House, Programs Seniors, N Vancouver, BC, Canada
关键词
point-of-care; self-testing; international normalized ratio; self-management; warfarin; anticoagulation;
D O I
10.1309/P2Y3VM4AXPVUDAW3
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Patients using anticoagulation point-of-care (POC) monitors are advised to periodically test these systems against laboratory methods to monitor performance. The international normalized ratio (INR), however, can vary between test systems owing to different instrument-reagent combinations. In a randomized study evaluating warfarin self-management, we compared INR measured by patients on a POC monitor (ProTime, International Technidyne Corporation, Edison, NJ) with those obtained at a hospital laboratory within 1 hour Ninety-one paired INR determinations from 55 patients met inclusion criteria. Clinical agreement in which POC and laboratory INR were within or outside the target INR range occurred in 56 (62%) of 91 cases (K = 0.35). The mean (SD) difference between POC and laboratory INR was 0.44 (0.61). Six pairs differed by 1 or more INR units, 3 at study initiation resulting in POC monitor replacement. The accuracy of INR self-testing with ProTime was acceptable. The small failure rate of INR agreement might be clinically important, suggesting the need for external quality control systems.
引用
收藏
页码:184 / 188
页数:5
相关论文
共 50 条
  • [21] Laboratory point-of-care monitoring in the operating room
    Rhee, Amanda J.
    Kahn, Ronald A.
    CURRENT OPINION IN ANESTHESIOLOGY, 2010, 23 (06) : 741 - 748
  • [22] Point-of-Care Ultrasound in Clinical Care: Abdomen
    Torres-Macho, Juan
    Schutzer, Christine M.
    MEDICAL CLINICS OF NORTH AMERICA, 2025, 109 (01) : 31 - 45
  • [23] Impact of rivaroxaban on point-of-care assays
    Fontana, Pierre
    Alberio, Lorenzo
    Angelillo-Scherrer, Anne
    Asmis, Lars M.
    Korte, Wolfgang
    Mendez, Adriana
    Schmid, Pirmin
    Stricker, Hans
    Studt, Jan-Dirk
    Tsakiris, Dimitrios A.
    Wuillemin, Walter A.
    Nagler, Michael
    THROMBOSIS RESEARCH, 2017, 153 : 65 - 70
  • [24] Acute kidney injury detection with additional point-of-care creatinine vs central laboratory serum creatinine measurement in critically ill patients
    White, Kyle C.
    Meyer, Jason
    Laupland, Kevin B.
    Senthuran, Siva
    Shekar, Kiran
    Mccullough, James
    Bellomo, Rinaldo
    JOURNAL OF CRITICAL CARE, 2025, 88
  • [25] Anticoagulation control with the point-of-care INR: A retrospective pre-/post-analysis
    Riva, Nicoletta
    Meli, Stephanie
    Xuereb, Christian Borg
    Vella, Kevin
    Ageno, Walter
    Makris, Michael
    Gatt, Alex
    THROMBOSIS RESEARCH, 2020, 196 : 21 - 24
  • [26] Economic evaluation of the use of point-of-care devices in patients with long term oral anticoagulation
    Gerkens, Sophie
    Gailly, Jeannine
    Obyn, Caroline
    Devriese, Stephan
    Cleemput, Irina
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2012, 34 (03) : 300 - 309
  • [27] Measurement of HbA 1c at the Point-of-Care - clinical and practical aspects
    Schubert-Olesen, Oliver
    Niederau, Christoph
    Danschel, Ingrid
    Mueller-Wieland, Dirk
    Wiesner, Tobias
    DIABETOLOGIE UND STOFFWECHSEL, 2025,
  • [28] Point-of-Care Testing in Hypercoagulable Conditions Managed With Warfarin A Review
    Faber, Nicholas N.
    Bulmer, Shanaya C.
    Gandhi, Mona A.
    Nagel, Angela K.
    POINT OF CARE, 2020, 19 (04): : 101 - 105
  • [29] Cerebrospinal Fluid Glucose Measurement at Point-of-Care
    Thomas, Steven
    Halstead, Anne Catherine
    Douglas, M. Joanne
    Villar, Giselle
    Saran, Simrat
    Kozak, Elvira
    POINT OF CARE, 2012, 11 (02): : 73 - 76
  • [30] Comparison of International Normalized Ratios provided by two point-of-care devices and laboratory-based venipuncture in a pharmacist-managed anticoagulation clinic
    Donaldson, Mark
    Sullivan, John
    Norbeck, Amber
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2010, 67 (19) : 1616 - 1622