Mechanical Surface Area of Prosthetic Heart Valve: Adverse Clinical Impact of Large Mechanical Valve in Mitral Position

被引:0
作者
Cho, Yang Hyun [1 ]
Sung, Kiick [1 ]
Kim, Wook Sung [1 ]
Kim, Jae-Hun [2 ]
Kim, Sung Mok [2 ,3 ]
Park, Pyo Won [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Thorac & Cardiovasc Surg, 81 Irwon Ro, Seoul 06351, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Cardiovasc Imaging Ctr,Heart Vasc Stroke Inst, Seoul, South Korea
关键词
mitral valve; surgery; prosthesis; thromboembolism; echocardiography; PATIENT MISMATCH; REPLACEMENT; SIZE; SURVIVAL; DISEASE;
D O I
10.1097/MAT.0000000000000718
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although thromboembolic accidents are serious adverse events associated with mechanical mitral valves, there have been no studies on the clinical impact of the large mechanical surface areas (MSAs) of mechanical mitral prostheses. Between 1995 and 2010, 488 consecutive adult patients underwent isolated mechanical mitral valve replacement. We measured the MSA via three-dimensional computed tomography for each prosthesis. Mean patient age was 50.6 +/- 11.1 years. The mean body surface area (BSA) and MSA index (MSAI, MSA/BSA) were 1.6 +/- 0.17 m(2) and 12.9 +/- 1.7cm(2)/m(2), respectively. The patients were divided into two groups according to the median MSAI. Patients in the high MSAI group had higher indexed left ventricular end-diastolic dimensions and smaller BSAs. The multivariate analysis demonstrated that old age, New York Heart Association class III or IV, and high MSAI were independent predictors of death. With respect to thromboembolic complications, New York Heart Association class III or IV and high MSAI were identified as independent risk factors. There were 11 patients (3%) with mean pressure gradients across the mitral valve greater than 6mm Hg 1 year after operation. A large MSA relative to patient size was identified as a predictor of poor clinical outcome after mechanical mitral valve replacement.
引用
收藏
页码:779 / 784
页数:6
相关论文
共 14 条
[11]   Prosthesis-patient mismatch: definition, clinical impact, and prevention [J].
Pibarot, P. ;
Dumesnil, J. G. .
HEART, 2006, 92 (08) :1022-1029
[12]  
Rao V, 2000, CIRCULATION, V102, P5
[13]   Impact of Prosthesis-Patient Mismatch on Late Recurrence of Atrial Fibrillation After Cryomaze Procedure With Mitral Valve Replacement [J].
Sato, Shunsuke ;
Fujita, Tomoyuki ;
Shimahara, Yusuke ;
Hata, Hiroki ;
Kobayashi, Junjiro .
CIRCULATION JOURNAL, 2014, 78 (08) :1908-1914
[14]  
Ulus AT, 2007, ANATOL J CARDIOL, V7, P397