An ultra-short perineal pad-test for evaluation of female stress urinary incontinence treatment

被引:21
作者
Persson, J [1 ]
Bergqvist, CE [1 ]
Wolner-Hanssen, P [1 ]
机构
[1] Univ Lund Hosp, Dept Obstet & Gynecol, S-22185 Lund, Sweden
关键词
evaluation of treatment; female stress incontinence; perineal pad-test;
D O I
10.1002/nau.1005
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
We assessed the reproducibility and feasibility of a rapid perineal pad-test designed for evaluation of stress urinary incontinence treatment. In an experimental study, we included 34 women with genuine stress incontinence, 13 with urge incontinence and 10 non-incontinent volunteers for a repeated pad-test with a standardized bladder volume (300 mL) and a standardized physical activity during one minute. The pad was weighed before and after the exercise to estimate the volume of any leaked urine. In order to find out the percentage of unselected, incontinent women who had been able to perform a preoperative pad-test. we identified all 120 women operated on for stress: incontinence during a one-year period in a separate retrospective analysis. In another retrospective analysis, we compared the subjective outcome of laparoscopic colposuspension with the outcome of the test performed before and after the procedure among 93 women with genuine stress incontinence. Among stress incontinent women, the median of the differences in leakage between the first and the second test was 8.5 mL (range 0-60 mL) and the repeatability coefficient was 33.6 mL. None of the 13 women with urge incontinence leaked during the tests. One of the 10 controls leaked (during both tests). Of the unselected women, 104/120 (87%) were able to perform the test. Reduction of leaking after surgery was significantly associated with subjective report of outcome (P < 0.0001). In conclusion, the described pad-test has an acceptable reproducibility and feasibility making it suitable for follow-up studies. Neurourol. Urodynam. 20:277-285, 2001. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:277 / 285
页数:9
相关论文
共 16 条
[1]  
ABRAMS P, 1990, BRIT J OBSTET GYN S, V97, P6
[2]  
BATES P, 1983, 5 REPORT STANDARDIZA
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   CLINICAL USE OF RECORDING NAPPY [J].
CALDWELL, KP .
UROLOGIA INTERNATIONALIS, 1974, 29 (03) :172-173
[5]   INTERDEPARTMENTAL AND INTRA-DEPARTMENTAL VARIATIONS OF THE PERINEAL PAD WEIGHING TEST [J].
CHRISTENSEN, SJ ;
COLSTRUP, H ;
HERTZ, JB ;
LENSTRUP, C ;
FRIMODTMOLLER, C .
NEUROUROLOGY AND URODYNAMICS, 1986, 5 (01) :23-28
[6]   OBJECTIVE QUANTIFICATION OF STRESS URINARY-INCONTINENCE - A SHORT, REPRODUCIBLE, PROVOCATIVE PAD-TEST [J].
HAHN, I ;
FALL, M .
NEUROUROLOGY AND URODYNAMICS, 1991, 10 (05) :475-481
[7]  
INGELMANSUNDBERG A, 1953, NORD MED, V50, P1149
[8]   PAD-WEIGHING TEST PERFORMED WITH STANDARDIZED BLADDER VOLUME [J].
LOSE, G ;
ROSENKILDE, P ;
GAMMELGAARD, J ;
SCHROEDER, T .
UROLOGY, 1988, 32 (01) :78-80
[9]   24-HOUR HOME PAD WEIGHING TEST VERSUS 1-HOUR WARD TEST IN THE ASSESSMENT OF MILD STRESS-INCONTINENCE [J].
LOSE, G ;
JORGENSEN, L ;
THUNEDBORG, P .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1989, 68 (03) :211-215
[10]   THE ONE-HOUR PAD-WEIGHING TEST - REPRODUCIBILITY AND THE CORRELATION BETWEEN THE TEST RESULT, THE START VOLUME IN THE BLADDER AND THE DIURESIS [J].
LOSE, G ;
GAMMELGAARD, J ;
JORGENSEN, TJ .
NEUROUROLOGY AND URODYNAMICS, 1986, 5 (01) :17-21