Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients

被引:96
作者
De Backer, Daniel [1 ]
Marx, Gernot [2 ]
Tan, Andrew [3 ]
Junker, Christopher [4 ]
Van Nuffelen, Marc [1 ]
Huter, Lars [5 ]
Ching, Willy [3 ]
Michard, Frederic [6 ]
Vincent, Jean-Louis [1 ]
机构
[1] Univ Libre Bruxelles, Dept Intens Care, Erasme Univ Hosp, B-1070 Brussels, Belgium
[2] Aachen Univ Hosp, Dept Surg Intens Care, D-52074 Aachen, Germany
[3] Queens Med Ctr, Intens Care Unit, Honolulu, HI 96813 USA
[4] Washington Univ, Med Ctr, Intens Care Unit, Washington, DC 20037 USA
[5] Jena Univ Hosp, D-07747 Jena, Germany
[6] Crit Care Europe, Edwards LifeSci, CH-1260 Nyon, Switzerland
关键词
Cardiac output; Monitoring; Non-invasive; Systemic vascular resistance; WAVE-FORM ANALYSIS; PULSE CONTOUR; BLOOD-PRESSURE; TRANSPULMONARY THERMODILUTION; AORTAS INVITRO; AGREEMENT;
D O I
10.1007/s00134-010-2098-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Second-generation FloTrac software has been shown to reliably measure cardiac output (CO) in cardiac surgical patients. However, concerns have been raised regarding its accuracy in vasoplegic states. The aim of the present multicenter study was to investigate the accuracy of the third-generation software in patients with sepsis, particularly when total systemic vascular resistance (TSVR) is low. Fifty-eight septic patients were included in this prospective observational study in four university-affiliated ICUs. Reference CO was measured by bolus pulmonary thermodilution (iCO) using 3-5 cold saline boluses. Simultaneously, CO was computed from the arterial pressure curve recorded on a computer using the second-generation (COG2) and third-generation (COG3) FloTrac software. CO was also measured by semi-continuous pulmonary thermodilution (CCO). A total of 401 simultaneous measurements of iCO, COG2, COG3, and CCO were recorded. The mean (95%CI) biases between COG2 and iCO, COG3 and iCO, and CCO and iCO were -10 (-15 to -5)% [-0.8 (-1.1 to -0.4) L/min], 0 (-4 to 4)% [0 (-0.3 to 0.3) L/min], and 9 (6-13)% [0.7 (0.5-1.0) L/min], respectively. The percentage errors were 29 (20-37)% for COG2, 30 (24-37)% for COG3, and 28 (22-34)% for CCO. The difference between iCO and COG2 was significantly correlated with TSVR (r (2) = 0.37, p < 0.0001). A very weak (r (2) = 0.05) relationship was also observed for the difference between iCO and COG3. In patients with sepsis, the third-generation FloTrac software is more accurate, as precise, and less influenced by TSVR than the second-generation software.
引用
收藏
页码:233 / 240
页数:8
相关论文
共 33 条
[1]   Evaluation of an uncalibrated arterial pulse contour cardiac output monitoring system in cirrhotic patients undergoing liver surgery [J].
Biancofiore, G. ;
Critchley, L. A. H. ;
Lee, A. ;
Bindi, L. ;
Bisa, M. ;
Esposito, M. ;
Meacci, L. ;
Mozzo, R. ;
DeSimone, P. ;
Urbani, L. ;
Filipponi, F. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (01) :47-54
[2]   DECREASED REFLECTION COEFFICIENT AS A POSSIBLE CAUSE OF LOW BLOOD-PRESSURE IN SEVERE SEPTICEMIA [J].
BILO, HJG ;
VANSCHIJNDEL, RJM ;
SCHREUDER, WO ;
GROENEVELD, ABJ ;
THIJS, LG .
INTENSIVE CARE MEDICINE, 1989, 15 (02) :137-139
[3]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[4]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[5]   Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions [J].
Della Rocca, Giorgio ;
Costa, Maria Gabriella ;
Chiarandini, Paolo ;
Bertossi, Gaia ;
Lugano, Manuela ;
Pompei, Livia ;
Coccia, Cecilia ;
Sainz-Barriga, Mauricio ;
Pietropaoli, Paolo .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2008, 22 (05) :681-687
[6]   Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients [J].
Dorman, T ;
Breslow, MJ ;
Lipsett, PA ;
Rosenberg, JM ;
Balser, JR ;
Almog, Y ;
Rosenfeld, BA .
CRITICAL CARE MEDICINE, 1998, 26 (10) :1646-1649
[7]  
Erlanger J., 1904, Bull Johns Hopkins Hosp, V12, P145
[8]   Effects of changes in vascular tone on the agreement between pulse contour and transpulmonary thermodilution cardiac output measurements within an up to 6-hour calibration-free period [J].
Hamzaoui, Olfa ;
Monnet, Xavier ;
Richard, Christian ;
Osman, David ;
Chemla, Denis ;
Teboul, Jean-Louis .
CRITICAL CARE MEDICINE, 2008, 36 (02) :434-440
[9]   On the accuracy of intra-arterial pressure measurement: The pressure gradient effect [J].
Hynson, JM ;
Katz, JA ;
Mangano, DT .
CRITICAL CARE MEDICINE, 1998, 26 (10) :1623-1624
[10]   Continuous cardiac output in septic shock by simulating a model of the aortic input impedance - A comparison with bolus injection thermodilution [J].
Jellema, WT ;
Wesseling, KH ;
Groeneveld, ABJ ;
Stoutenbeek, CP ;
Thijs, LG ;
van Lieshout, JJ .
ANESTHESIOLOGY, 1999, 90 (05) :1317-1328