Spectroscopy on thick HgI2 detectors:: A comparison between planar and pixelated electrodes

被引:0
作者
Baciak, JE [1 ]
He, Z [1 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
来源
2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3 | 2003年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Thick mercuric iodide (HgI2) detectors are investigated as potential room temperature gamma-ray spectrometers. By using pixelated anodes the induced charge on the electrode is dependent mainly on electron movement and is almost independent of the depth of interaction. Moreover, by reading out the planar cathode signal simultaneously, the depth of interaction can be determined and any effects of electron charge loss can be corrected. By combining these two methods (pixelated anodes and depth sensing), the resolution from 1 cm thick HgI2 devices can be improved to 1.4% FWHM when using a Cs-137 point source. These results were made using a modest electric field (2500 V/cm) and relatively short shaping times (4-16 mus) for HgI2. comparison between conventional planar readout and single polarity charge sensing techniques with wide band-gap semiconductors is discussed.
引用
收藏
页码:439 / 443
页数:5
相关论文
共 11 条
[1]   Electron trapping variations in single-crystal pixelated HgI2 gamma-ray spectrometers [J].
Baciak, JE ;
He, Z ;
DeVito, RP .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) :1264-1269
[2]  
BACIAK JE, UNPUB DEV MODEL GAMM
[3]  
BACIAK JE, UNPUB COMP 5 MM 10 M
[4]   CHARGE-TRANSPORT IN ARRAYS OF SEMICONDUCTOR GAMMA-RAY DETECTORS [J].
BARRETT, HH ;
ESKIN, JD ;
BARBER, HB .
PHYSICAL REVIEW LETTERS, 1995, 75 (01) :156-159
[5]   PULSE FILTERING FOR THICK MERCURIC IODIDE DETECTORS [J].
GERRISH, VM ;
WILLIAMS, DJ ;
BEYERLE, AG .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) :85-90
[6]   1-D position sensitive single carrier semiconductor [J].
He, Z ;
Knoll, GF ;
Wehe, DK ;
Rojeski, R ;
Mastrangelo, CH ;
Hammig, M ;
Barrett, C ;
Uritani, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :228-231
[7]   Direct measurement of product of the electron mobility and mean free drift time of CdZnTe semiconductors using position sensitive single polarity charge sensing detectors [J].
He, Z ;
Knoll, GF ;
Wehe, DK .
JOURNAL OF APPLIED PHYSICS, 1998, 84 (10) :5566-5569
[8]   Investigation of pixellated HgI2 γ-ray spectrometers [J].
He, Z ;
Vigil, RD .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 492 (03) :387-401
[9]   3-D position sensitive CdZnTe gamma-ray spectrometers [J].
He, Z ;
Li, W ;
Knoll, GF ;
Wehe, DK ;
Berry, J ;
Stahle, CM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :173-178
[10]  
PONPON JP, 1974, NUCL I METH, V119