Cerebral MR venography in children: Comparison of 2D time-of-flight and gadolinium-enhanced 3D gradient-echo techniques

被引:36
|
作者
Rollins, N
Ison, C
Reyes, T
Chia, J
机构
[1] Childrens Med Ctr, Dept Radiol, Dallas, TX 75235 USA
[2] Univ Texas, SW Med Ctr, Dallas, TX 75235 USA
[3] Philips Med Syst, Best, Netherlands
关键词
D O I
10.1148/radiol.2353041427
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively compare two-dimensional (2D) time-of-flight cerebral magnetic resonance (MR) venography with gadolinium-enhanced three-dimensional (3D) gradient-echo cerebral MR venography in children. MATERIALS AND METHODS: This investigation had investigational review board approval and was Health Insurance Portability and Accountability Act compliant; parental informed consent was obtained. Thirty-seven patients (20 boys, 17 girls) who ranged in age from 4 days to 15 years underwent 2D and 3D MR venography. Two pediatric neuroradiologists compared the visibility of the superior sagittal, straight, transverse, and sigmoid sinuses and the internal jugular veins on images obtained with the two sequences. RESULTS: In 17 (46%) of the 37 patients, the sequences were equivalent in terms of their depiction of venous anatomy. In 19 (51%) of the 37 patients, 3D MR venography was superior to 2D MR venography. Suboptimal enhancement of veins occurred in one (3%) patient at 3D MR venography. Venous anomalies suggested at 2D MR venography but not present at 3D MR venography included flow gaps in the nondominant transverse sinuses of four patients, unilateral transverse sinus atresia in eight, and a narrowed superior sagittal sinus in two. Two-dimensional MR venography results failed to reveal a persistent falcine sinus associated with straight sinus atresia in one patient and suggested transverse sinus thrombosis in two patients in whom 3D MR venography results were normal. Additionally, the extent of dural thrombosis was overestimated at 2D MR venography in one patient. As compared with 3D MR venography, 2D MR venography failed to reveal sigmoid sinus stenosis in one patient and poorly depicted posterior fossa dural sinus anatomy in two patients with dural arteriovenous fistula. CONCLUSION: Three-dimensional MR venography is often superior to 2D MR venography in the delineation of major cerebral venous structures in children. Most of the artifactual loss of vascular signal seen with the use of 2D MR venography occurred in nondominant transverse sinuses. (c) RSNA 2005
引用
收藏
页码:1011 / 1017
页数:7
相关论文
共 50 条
  • [41] ILIAC ARTERY NIR ANGIOGRAPHY - COMPARISON OF 3-DIMENSIONAL GADOLINIUM-ENHANCED AND 2-DIMENSIONAL TIME-OF-FLIGHT TECHNIQUES
    SNIDOW, JJ
    AISEN, AM
    HARRIS, VJ
    TREROTOLA, SO
    JOHNSON, MS
    SAWCHUK, AP
    DALSING, MC
    RADIOLOGY, 1995, 196 (02) : 371 - 378
  • [42] Comparison between 2D and 3D gradient-echo sequences for MRI of human lung ventilation with hyperpolarized 3He
    Wild, JM
    Woodhouse, N
    Paley, MNJ
    Fichele, S
    Said, Z
    Kasuboski, L
    van Beek, EJR
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) : 673 - 678
  • [43] GADOLINIUM-ENHANCED ULTRAFAST 3D TIME-OF-FLIGHT IMAGING OF THE ABDOMINAL-AORTA AND VISCERAL VESSELS - TECHNIQUE AND PICTORIAL REVIEW
    GILFEATHER, M
    HOLLAND, GA
    DOUGHERTY, L
    GREENMAN, RL
    AXEL, L
    SCHNALL, MD
    RADIOLOGY, 1995, 197 : 517 - 517
  • [44] RENAL-ARTERIES - EVALUATION WITH OPTIMIZED 2D AND 3D TIME-OF-FLIGHT MR-ANGIOGRAPHY
    FELLNER, C
    STROTZER, M
    GEISSLER, A
    KOHLER, SM
    KRAMER, BK
    SPIES, V
    HELD, P
    GMEINWIESER, J
    RADIOLOGY, 1995, 196 (03) : 681 - 687
  • [45] Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI
    Aymerich, F. X.
    Auger, C.
    Alcaide-Leon, P.
    Pareto, D.
    Huerga, E.
    Corral, J. F.
    Mitjana, R.
    Sastre-Garriga, J.
    Montalban, X.
    Rovira, A.
    EUROPEAN RADIOLOGY, 2017, 27 (04) : 1361 - 1368
  • [46] Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI
    F. X. Aymerich
    C. Auger
    P. Alcaide-Leon
    D. Pareto
    E. Huerga
    J. F. Corral
    R. Mitjana
    J. Sastre-Garriga
    X. Montalban
    A. Rovira
    European Radiology, 2017, 27 : 1361 - 1368
  • [47] Gadolinium-enhanced 3D MR angiography of the renal arteries: Clinical experiences
    Joergensen, M
    Galanski, MW
    Rosenthal, H
    Chavan, A
    Brunkhorst, R
    RADIOLOGY, 1997, 205 : 274 - 274
  • [48] CONTRAST MATERIAL-ENHANCED MR ANGIOGRAPHY FOR INTRACRANIAL ANEURYSMS WITH 3D TIME-OF-FLIGHT AND 3D PHASE-CONTRAST TECHNIQUES
    CHUNG, WC
    LISTERUD, J
    ATLAS, SW
    RADIOLOGY, 1992, 185 : 121 - 121
  • [49] Comparison of 2D echo techniques with real-time 3D echo when measuring left atrial volumes
    Jenkins, C
    Bricknell, K
    Marwick, TH
    EUROPEAN HEART JOURNAL, 2004, 25 : 262 - 262
  • [50] Quantitative comparison of 2D and 3D late gadolinium enhancement MR imaging for cardiomyopathies
    Fabian Morsbach
    Sonja Gordic
    Robert Götti
    Markus Niemann
    Hatem Alkadhi
    Gruner Christiane
    Robert Manka
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)