Scanning electron microscopy (SEM) and X-ray dispersive spectrometry evaluation of direct laser metal sintering surface and human bone interface: a case series

被引:29
作者
Mangano, Carlo [2 ]
Piattelli, Adriano [3 ]
Raspanti, Mario [4 ]
Mangano, Francesco
Cassoni, Alessandra [5 ]
Iezzi, Giovanna
Shibli, Jamil Awad [1 ]
机构
[1] Univ Guarulhos, Dept Periodontol, Dent Res Div, BR-07011040 Guarulhos, SP, Brazil
[2] Univ Insubria Varese, Dept Biomat, Varese, Italy
[3] Univ G dAnnunzio, Dept Oral Med & Pathol, Chieti, Italy
[4] Univ Insubria Varese, Dept Human Morphol, Varese, Italy
[5] Univ Guarulhos, Dept Restorat Dent, BR-07011040 Guarulhos, SP, Brazil
关键词
Dental implants; Human histology; Implant surface topography; Laser manufacturing; Osseointegration; Wound healing; DIFFERENT IMPLANT SURFACES; HISTOLOGIC EVALUATION; ENDOSSEOUS INTEGRATION; TITANIUM IMPLANTS; DENTAL IMPLANTS; MANUFACTURE; GROWTH; DIFFERENTIATION; TISSUES;
D O I
10.1007/s10103-010-0831-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recent studies have shown that direct laser metal sintering (DLMS) produces structures with complex geometry and consequently that allow better osteoconductive properties. The aim of this patient report was to evaluate the early bone response to DLMS implant surface retrieved from human jaws. Four experimental DLMS implants were inserted in the posterior mandible of four patients during conventional dental implant surgery. After 8 weeks, the micro-implants and the surrounding tissue were removed and prepared for scanning electron microscopy (SEM) and histomorphometric analysis to evaluate the bone-implant interface. The SEM and EDX evaluations showed a newly formed tissue composed of calcium and phosphorus. The bone-to-implant contact presented a mean of 60.5 +/- 11.6%. Within the limits of this patient report, data suggest that the DLMS surfaces presented a close contact with the human bone after a healing period of 8 weeks.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 26 条
[1]   The manufacturing of hard tools from metallic powders by selective laser melting [J].
Abe, F ;
Osakada, K ;
Shiomi, M ;
Uematsu, K ;
Matsumoto, M .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2001, 111 (1-3) :210-213
[2]   Manufacture, characterisation and application of cellular metals and metal foams [J].
Banhart, J .
PROGRESS IN MATERIALS SCIENCE, 2001, 46 (06) :559-U3
[3]  
Buser D, 1999, J BIOMED MATER RES, V45, P75, DOI 10.1002/(SICI)1097-4636(199905)45:2<75::AID-JBM1>3.0.CO
[4]  
2-P
[5]   Rapid manufacturing of metal components by laser forming [J].
Costa Santos, Edson ;
Shiomi, Masanari ;
Osakada, Kozo ;
Laoui, Tahar .
INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2006, 46 (12-13) :1459-1468
[6]  
Davies JE, 1998, INT J PROSTHODONT, V11, P391
[7]   Quantitative evaluation of the fibrin clot extension on different implant surfaces:: An in vitro study [J].
Di Iorio, D ;
Traini, T ;
Degidi, M ;
Caputi, S ;
Neugebauer, J ;
Piattelli, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 74B (01) :636-642
[8]  
FAGHIHI S, 2005, ICOTOM 1, V14, P705
[9]   Histologic evaluation of early human bone response to different implant surfaces [J].
Grassi, Sauro ;
Piattelli, Adriano ;
de Figueiredo, Luciene Cristina ;
Feres, Magda ;
de Melo, Leandro ;
Lezzi, Giovanna ;
Alba, Rodolfo Candia, Jr. ;
Shibli, Jamil Awad .
JOURNAL OF PERIODONTOLOGY, 2006, 77 (10) :1736-1743
[10]  
Ivanoff CJ, 2003, INT J ORAL MAX IMPL, V18, P341