Comparative Study of Energy Savings for Various Control Strategies in the Tunnel Lighting System

被引:14
作者
Qin, Li [1 ]
Pena-Garcia, Antonio [2 ]
Leon, Arturo S. [3 ]
Yu, Jian-Cheng [1 ]
机构
[1] Ningbo Univ, Dept Informat Sci & Engn, Ningbo 315211, Peoples R China
[2] Univ Granada, Dept Civil Engn, Granada 18074, Spain
[3] Florida Int Univ, Coll Engn & Comp, Dept Civil & Environm Engn, Miami, FL 33174 USA
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 14期
基金
中国国家自然科学基金;
关键词
lighting control system; energy savings; control strategy; LED lighting; ROAD PRE-TUNNELS; SUNLIGHT; METHODOLOGY; LUMINANCE; PAVEMENT; PERGOLAS; VEHICLE; PORTALS; PIPES;
D O I
10.3390/app11146372
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Tunnel lighting is the most significant component in total energy consumption in the whole infrastructure. Hence, various lighting control strategies based on light-emitting diode (LED) technology have been investigated to conserve energy by decreasing luminaires' operating time. In this study, four kinds of tunnel lighting control strategies and the development of their associated technologies are evaluated: no-control low-consumption lamps (LCL), time-scheduling control strategy (TSCS), daylight adaptation control strategy (DACS), and intelligent control strategy (ICS). This work investigates the relationship between initial investment and electrical costs as a function of tunnel length (L) and daily traffic volume (N) for the four control strategies. The analysis was performed using 100-day data collected in eleven Chinese tunnels. The tunnel length (L) ranged from 600 m to 3300 m and the daily traffic volume (N) ranged from 700 to 2500. The results showed that initial investment costs increase with L for all control strategies. Also, the electricity costs for the LCL, TSCS, and DACS strategies increased linearly with L, whereas the electricity cost for the ICS strategy has an exponential growth with L and N. The results showed that for a lifetime equal to or shorter than 218 days, the LCL strategy offered the best economical solution; whereas for a lifetime longer than 955 days, the ICS strategy offered the best economical solution. For a lifetime between 218 and 955 days, the most suitable strategy varies with tunnel length and traffic volume. This study's results can guide the decision-making process during the tunnel lighting system's design stage.
引用
收藏
页数:17
相关论文
共 43 条
  • [1] Aksoy A, 2018, TURK J ELECTROMECH E, V3, P5
  • [2] [Anonymous], 2014, JTGTD702012014
  • [3] [Anonymous], 2019, P 2019 IEEE INT C EN, DOI DOI 10.1109/EEEIC.2019.8783789
  • [4] Overview of traffic safety aspects and design in road tunnels
    Bassan, Shy
    [J]. IATSS RESEARCH, 2016, 40 (01) : 35 - 46
  • [5] Natural lighting of road pre-tunnels: A methodology to assess the luminance on the pavement - Part I
    Cantisani, Giuseppe
    D'Andrea, Antonio
    Moretti, Laura
    [J]. TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 73 : 37 - 47
  • [6] Natural lighting of road pre-tunnels: A methodology to assess the luminance on the pavement - Part II
    Cantisani, Giuseppe
    D'Andrea, Antonio
    Moretti, Laura
    [J]. TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 73 : 170 - 178
  • [7] Commission Internationale de l'Eclairage CIE., 2004, GUID LIGHT ROAD TUNN GUID LIGHT ROAD TUNN, V88
  • [8] Drakou D, 2015, 2015 IEEE 15TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (IEEE EEEIC 2015), P649, DOI 10.1109/EEEIC.2015.7165241
  • [9] Du Z. G., 2018, Journal of Wuhan University of Technology (Transportation Science & Engineering), V42, P715
  • [10] Du Zhi-gang, 2020, Journal of Traffic and Transportation Engineering, V20, P215, DOI 10.19818/j.cnki.1671-1637.2020.01.018