Semi-active tuned mass damper control strategy for wind-excited structures

被引:44
作者
Ricciardelli, F
Occhiuzzi, A
Clemente, P
机构
[1] Univ Naples Federico II, Dipartimento Anat & Progettazione Strutturale, I-80125 Naples, Italy
[2] Univ Reggio Calabria, Dipartimento Meccan & Mat, Calabria, Italy
[3] ENEA, Ctr Ric Casaccia, Rome, Italy
关键词
tuned mass damper (TMD); semi-active control; wind-excited structures;
D O I
10.1016/S0167-6105(00)00024-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Uncertainties in the main structure dynamic properties as well as those in the characteristics of the excitation may cause a deterioration of the performance of Tuned Mass Dampers. This may happen because the choice of tuning and damping ratio of the auxiliary system, based on the expected values of the dynamic properties of the main structure and on a simple excitation pattern, may prove away from the optimum. An empirical algorithm is presented in this paper which allows the performance of the TMD to be optimised, based on the measured response. The algorithm relies on two assumptions: the smoothness of the spectrum of excitation and the availability of an estimate of the dynamic properties of the main structure. As an example the algorithm is applied to a 64-story building subjected to turbulence buffeting. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:57 / 74
页数:18
相关论文
共 50 条
  • [41] Experimental study of a semi-active damper
    Boichot, P
    Jezequel, L
    MECANIQUE INDUSTRIELLE ET MATERIAUX, 1996, 49 (03): : 130 - 132
  • [42] Semi-active vibration control via a magnetorheological damper and active disturbance rejection control
    Rodriguez-Torres, Andres
    Morales-Valdez, Jesus
    Yu, Wen
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2024,
  • [43] Wind response control of tall buildings with a tuned mass damper
    Elias, Said
    Matsagar, Vasant
    JOURNAL OF BUILDING ENGINEERING, 2018, 15 : 51 - 60
  • [44] Use of semi-active tuned mass dampers to control footbridges subjected to synchronous lateral excitation
    Ferreira, Fernando
    Moutinho, Carlos
    Cunha, Alvaro
    Caetano, Elsa
    JOURNAL OF SOUND AND VIBRATION, 2019, 446 : 176 - 194
  • [45] Simulation Study of Semi-Active Control of Stay Cable Using MR Damper under Wind Loads
    Liu, Jiangyun
    Huang, Hongwei
    Sun, Limin
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS 2013, 2013, 8688
  • [46] Rotating semi-active tuned liquid column damper for bi-directional eccentric structural seismic response control
    Fu, Cong
    Wang, Liangkun
    Wang, Zhipeng
    Xue, Songtao
    Xie, Liyu
    JOURNAL OF BUILDING ENGINEERING, 2025, 103
  • [47] Mechanical performance analysis of a piezoelectric ceramic friction damper and research of its semi-active control strategy
    Wang, Tianlong
    Zhang, Xun'an
    Li, Kun
    Yang, Shixuan
    STRUCTURES, 2021, 33 : 1510 - 1531
  • [48] Semi-Active Control of Vehicle Seat Suspension System with Magnetorheological Damper
    Xing, Haijun
    Yang, Shaopu
    Shen, Yongjun
    MECHATRONICS AND INFORMATION TECHNOLOGY, PTS 1 AND 2, 2012, 2-3 : 1067 - 1070
  • [49] Semi-Active Control of Stay Cable Vibrations Using Magnetorheological Damper
    Gurav, Rohit Tukaram
    Ali, Shaikh Faruque
    2018 7TH INTERNATIONAL CONFERENCE ON SYSTEMS AND CONTROL (ICSC), 2018, : 354 - 359
  • [50] Semi-Active Vibration Control of Water-Conveying Pipeline Based on Magnetorheological Damper
    Pang, Sen
    Zhang, Xuesong
    Jiang, Zihang
    Yang, Haixu
    Zhou, Shengming
    Zhao, Qiang
    PROCESSES, 2025, 13 (02)