Semi-active tuned mass damper control strategy for wind-excited structures

被引:44
|
作者
Ricciardelli, F
Occhiuzzi, A
Clemente, P
机构
[1] Univ Naples Federico II, Dipartimento Anat & Progettazione Strutturale, I-80125 Naples, Italy
[2] Univ Reggio Calabria, Dipartimento Meccan & Mat, Calabria, Italy
[3] ENEA, Ctr Ric Casaccia, Rome, Italy
关键词
tuned mass damper (TMD); semi-active control; wind-excited structures;
D O I
10.1016/S0167-6105(00)00024-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Uncertainties in the main structure dynamic properties as well as those in the characteristics of the excitation may cause a deterioration of the performance of Tuned Mass Dampers. This may happen because the choice of tuning and damping ratio of the auxiliary system, based on the expected values of the dynamic properties of the main structure and on a simple excitation pattern, may prove away from the optimum. An empirical algorithm is presented in this paper which allows the performance of the TMD to be optimised, based on the measured response. The algorithm relies on two assumptions: the smoothness of the spectrum of excitation and the availability of an estimate of the dynamic properties of the main structure. As an example the algorithm is applied to a 64-story building subjected to turbulence buffeting. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:57 / 74
页数:18
相关论文
共 50 条
  • [21] Smart Semi-active PID-ACO control strategy for tower vibration reduction in Wind Turbines with MR damper
    Rahman, Mahmudur
    Ong, Zhi Chao
    Chong, Wen Tong
    Julai, Sabariah
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2019, 18 (04) : 887 - 902
  • [22] Smart Semi-active PID-ACO control strategy for tower vibration reduction in Wind Turbines with MR damper
    Mahmudur Rahman
    Zhi Chao Ong
    Wen Tong Chong
    Sabariah Julai
    Earthquake Engineering and Engineering Vibration, 2019, 18 : 887 - 902
  • [23] Smart Semi-active PID-ACO control strategy for tower vibration reduction in Wind Turbines with MR damper
    Mahmudur Rahman
    Zhi Chao Ong
    Wen Tong Chong
    Sabariah Julai
    EarthquakeEngineeringandEngineeringVibration, 2019, 18 (04) : 887 - 902
  • [24] Fuzzy control of earthquake-excited mill structure using semi-active friction damper
    Wang, JW
    Chen, B
    Qu, WL
    Chen, ZH
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2002, : 438 - 443
  • [25] Studies on vibration control effects of a semi-active impact damper for seismically excited nonlinear building
    Lu, Zheng
    Zhang, Hengrui
    Masri, Sami F.
    SMART STRUCTURES AND SYSTEMS, 2019, 24 (01) : 95 - 110
  • [26] Analytical and experimental studies on building mass damper system with semi-active control device
    Liu, Yu-Fang
    Lin, Tzu-Kang
    Chang, Kuo-Chun
    STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (06):
  • [27] Control of wind-induced nonlinear oscillations in suspension bridges using multiple semi-active tuned mass dampers
    Abdel-Rohman, Mohamed
    John, Mariam Joseph
    JOURNAL OF VIBRATION AND CONTROL, 2006, 12 (09) : 1011 - 1046
  • [28] LQR Control of Wind Excited Benchmark Building Using Variable Stiffness Tuned Mass Damper
    Deshmukh, S. N.
    Chandiramani, N. K.
    SHOCK AND VIBRATION, 2014, 2014
  • [29] Seismic Response Control of a Nonlinear Tall Building Under Mainshock-Aftershock Sequences Using Semi-Active Tuned Mass Damper
    Wang, Liangkun
    Zhou, Ying
    Shi, Weixing
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2023, 23 (16N18)
  • [30] Control method based on energy absorption rate of semi-active controlled tuned mass damper adaptable to a structure' s period fluctuation
    NAKAI T.
    KURINO H.