MRI of the anterior talofibular ligament, talar cartilage and os subfibulare: Comparison of isotropic resolution 3D and conventional 2D T2-weighted fast spin-echo sequences at 3.0 T

被引:26
作者
Yi, Jisook [1 ]
Cha, Jang Gyu [1 ]
Lee, Young Koo [2 ]
Lee, Bo Ra [3 ]
Jeon, Chan Hong [4 ]
机构
[1] Soonchunhyang Univ, Bucheon Hosp, Dept Radiol, 170 Jomaru Ro, Bucheon Si 14584, South Korea
[2] Soonchunhyang Univ, Bucheon Hosp, Dept Orthoped, 170 Jomaru Ro, Bucheon Si 14584, South Korea
[3] Soonchunhyang Univ, Bucheon Hosp, Dept Biomed Stat, 170 Jomaru Ro, Bucheon Si 14584, South Korea
[4] Soonchunhyang Univ, Bucheon Hosp, Dept Internal Med, Div Rheumatol, 170 Jomaru Ro, Bucheon Si 14584, South Korea
关键词
Ankle; 3-Tesla; Isotropic magnetic resonance imaging; ATFL; Chondral lesion of the talus; Os subfibulare; ARTHROSCOPIC CORRELATION; ANKLE INSTABILITY; PROTON-DENSITY; ROTATOR CUFF; ARTHROGRAPHY; DIAGNOSIS; SHOULDER; LESIONS; INJURY; TALUS;
D O I
10.1007/s00256-016-2367-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To determine the accuracy of a three-dimensional (3D) T2-weighted fast spin-echo (FSE) magnetic resonance (MR) sequence compared with two-dimensional (2D) sequence for diagnosing anterior talofibular ligament (ATFL) tears, chondral lesion of the talus (CLT) and os subfibulare/avulsion fracture of the distal fibula (OSF). Thirty-five patients were included, who had undergone ankle MRI with 3D T2-weighted FSE and 2D T2-weighted FSE sequences, as well as subsequent ankle arthroscopy, between November 2013 and July 2014. Each MR imaging sequence was independently scored by two readers retrospectively for the presence of ATFL tears, CLT and OSF. The area under the receiver operating curve (AUC) was compared to determine the discriminatory power of the two image sequences. Interobserver agreement was expressed as unweighted kappa value. Arthroscopic findings confirmed 21 complete tears of the ATFL, 14 partial tears of the ATFL, 17 CLTs and 7 OSFs. There were no significant differences in the diagnoses of ATFL tears (p = 0.074-0.501), CLT (p = 0.090-0.450) and OSF (p = 0.317) obtained from the 2D and 3D sequences by either reader. The interobserver agreement rates between two readers using the 3D T2-weighted FSE sequence versus those obtained with the 2D sequence were substantial (kappa = 0.659) versus moderate (kappa = 0.553) for ATFL tears, moderate (kappa = 0.499) versus substantial (kappa = 0.676) for CLT and substantial (kappa = 0.621) versus substantial (kappa = 0.689) for OSF. Three-dimensional isotropic T2-weighted FSE MRI of the ankle resulted in no statistically significant difference in diagnostic performance compared to two-dimensional T2-weighted FSE MRI in the evaluation of ATFL tears, CLTs and OSFs.
引用
收藏
页码:899 / 908
页数:10
相关论文
共 36 条
[1]   Treatment of complete rupture of the lateral ligaments of the ankle:: a randomized clinical trial comparing cast immobilization with functional treatment [J].
Ardèvol, J ;
Bolíbar, I ;
Belda, V ;
Argilaga, S .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (06) :371-377
[2]   THE SYMPTOMATIC OS SUBFIBULARE - AVULSION FRACTURE OF THE FIBULA ASSOCIATED WITH RECURRENT INSTABILITY OF THE ANKLE [J].
BERG, EE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (08) :1251-1254
[3]  
Buckwalter, 1994, J Am Acad Orthop Surg, V2, P192
[4]   MR Imaging of Ankle Inversion Injuries [J].
Campbell, Scot E. ;
Warner, Meredith .
MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2008, 16 (01) :1-+
[5]   ANKLE INSTABILITY - CURRENT CONCEPTS, DIAGNOSIS, AND TREATMENT [J].
CASS, JR ;
MORREY, BF .
MAYO CLINIC PROCEEDINGS, 1984, 59 (03) :165-170
[6]  
Chan KW, 2011, BULL HOSP JT DIS, V69, P17
[7]   Comparison of Three-dimensional Isotropic T1-weighted Fast Spin-Echo MR Arthrography with Two-dimensional MR Arthrography of the Shoulder [J].
Choo, Hye Jung ;
Lee, Sun Joo ;
Kim, Ok-Hwoa ;
Seo, Seung Suk ;
Kim, Jung Han .
RADIOLOGY, 2012, 262 (03) :921-931
[8]  
DeLee JC, 2003, DELEE DREZS ORTHOPAE
[9]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[10]   PROPELLER Technique to Improve Image Quality of MRI of the Shoulder [J].
Dietrich, Tobias J. ;
Ulbrich, Erika J. ;
Zanetti, Marco ;
Fucentese, Sandro F. ;
Pfirrmann, Christian W. A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (06) :W1093-W1100