Spectral sensitivity of Bacillus subtilis spores and MS2 Coliphage for validation testing of ultraviolet reactors for water disinfection

被引:103
作者
Mamane-Gravetz, H
Linden, KG
Cabaj, A
Sommer, R
机构
[1] Med Univ Vienna, Clin Inst Hyg & Med Microbiol, A-1095 Vienna, Austria
[2] Tel Aviv Univ, Porter Sch Environm, Sch Mech Engn, IL-69978 Tel Aviv, Israel
[3] Duke Univ, Dept Civil & Environm Engn, Durham, NC 27708 USA
[4] Univ Vet Med, Inst Med Phys & Biostat, A-1210 Vienna, Austria
关键词
D O I
10.1021/es048446t
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The microbicidal UV fluence under polychromatic radiation from UV lamps is typically measured using the DNA absorbance spectrum as a weighting factor for the relative wavelength effectiveness. However, this DNA-based weighting does not necessarily match the spectral sensitivity of the microorganism being tested. Bacillus subtilis spores are often used for UV reactor validation in Europe, while MS2 coliphage is typically used for validation testing in the United States. These organisms were exposed to quasi-monochromatic UV irradiation across the microbicidal spectrum at wavelengths of 214, 230, 240, 254, 265, 280, and 293 nm. MS2 was three times more sensitive to wavelengths near 214 nm compared to the 254 nm output of low-pressure lamps, while B. subtilis spores were most sensitive to wavelengths around 265 nm. Use of these action spectra, compared to the DNA-based weighting, resulted in differences in the calculated polychromatic UV fluence. Consequently, the action spectrum, which is specific for each microorganism, has implications on the uncertainty of UV fluence determination during validation of reactors with polychromatic UV lamps.
引用
收藏
页码:7845 / 7852
页数:8
相关论文
共 36 条
  • [1] ABSHIRE LR, 1980, APPL ENVIRON MICROB, V39, P695
  • [2] Batch LE, 2004, J AM WATER WORKS ASS, V96, P75
  • [3] Standardization of methods for fluence (UV dose) determination in bench-scale UV experiments
    Bolton, JR
    Linden, KG
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2003, 129 (03): : 209 - 215
  • [4] The spectral UV sensitivity of microorganisms used in biodosimetry
    Cabaj, A
    Sommer, R
    Pribil, W
    Haider, T
    [J]. 2ND WORLD WATER CONGRESS: WATER AND HEALTH-MICROBIOLOGY, MONITORING AND DISINFECTION, 2002, 2 (03): : 175 - 181
  • [5] Biodosimetry: Model calculations for uv water disinfection devices with regard to dose distributions
    Cabaj, A
    Sommer, R
    Schoenen, D
    [J]. WATER RESEARCH, 1996, 30 (04) : 1003 - 1009
  • [6] What means "dose" in UV-disinfection with medium pressure lamps?
    Cabaj, A
    Sommer, R
    Pribil, W
    Haider, T
    [J]. OZONE-SCIENCE & ENGINEERING, 2001, 23 (03) : 239 - 244
  • [7] Measurement of ultraviolet radiation with biological dosemeters
    Cabaj, A
    Sommer, R
    [J]. RADIATION PROTECTION DOSIMETRY, 2000, 91 (1-3) : 139 - 142
  • [8] Clancy JL, 2000, J AM WATER WORKS ASS, V92, P97
  • [9] Davidson J. N., 1965, The Biochemistry of the Nucleic Acids
  • [10] On nuclear derivatives and the lethal action of ultra-violet light
    Gates, FL
    [J]. SCIENCE, 1928, 68 : 479 - 480