Detection of Intracochlear Damage With Cochlear Implantation in a Gerbil Model of Hearing Loss

被引:42
作者
Choudhury, Baishakhi [1 ]
Adunka, Oliver Franz [1 ]
DeMason, Christine E. [1 ]
Ahmad, Faisal I. [1 ]
Buchman, Craig A. [1 ]
Fitzpatrick, Douglas C. [1 ]
机构
[1] Univ N Carolina, Dept Otolaryngol Head & Neck Surg, Chapel Hill, NC 27599 USA
关键词
Cochlear electrophysiology; Cochlear implant; Electric-acoustic stimulation; Hearing preservation; Noise damage; FREQUENCY MAP; ADULT; CATS;
D O I
10.1097/MAO.0b013e31822f09f2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Hypothesis: Cochlear trauma due to electrode insertion can be detected in acoustic responses to low frequencies in an animal model with a hearing condition similar to patients using electroacoustic stimulation. Background: Clinical evidence suggests that intracochlear damage during cochlear implantation negatively affects residual hearing. Recently, we demonstrated the usefulness of acoustically evoked potentials to detect cochlear trauma in normal-hearing gerbils. Here, gerbils with noise-induced hearing loss were used to investigate the effects of remote trauma on residual hearing. Methods: Gerbils underwent high-pass (4-kHz cutoff) noise exposure to produce sloping hearing loss. After 1 month of recovery, each animal's hearing loss was determined from auditory brainstem responses and baseline intracochlear recording of the cochlear microphonic and compound action potential (CAP) obtained at the round window. Subsequently, electrode insertions were performed to produce basal trauma, whereas the acoustically generated potentials to a 1-kHz tone-burst were recorded after each step of electrode advancement. Hair cell counts were made to characterize the noise damage, and cochlear whole mounts were used to identify cochlear trauma due to the electrode. Results: The noise exposure paradigm produced a pattern of hair cell, auditory brainstem response, and intracochlear potential losses that closely mimicked that of electrical and acoustic stimulation patients. Trauma in the basal turn, in the 15- to 30-kHz portion of the deafened region, remote from preserved hair cells, induced a decline in intracochlear acoustic responses to the hearing preserved frequency of 1 kHz. Conclusion: The results indicate that a recording algorithm based on physiological markers to low-frequency acoustic stimuli can identify cochlear trauma during implantation. Future work will focus on translating these results for use with current cochlear implant technology in humans.
引用
收藏
页码:1370 / 1378
页数:9
相关论文
共 50 条
  • [1] Detection of intracochlear damage during cochlear implant electrode insertion using extracochlear measurements in the gerbil
    Ahmad, Faisal I.
    Choudhury, Baishakhi
    De Mason, Christine E.
    Adunka, Oliver F.
    Finley, Charles C.
    Fitzpatrick, Douglas C.
    LARYNGOSCOPE, 2012, 122 (03) : 636 - 644
  • [2] Intracochlear Electrocochleography: Response Patterns During Cochlear Implantation and Hearing Preservation
    Giardina, Christopher K.
    Brown, Kevin D.
    Adunka, Oliver F.
    Buchman, Craig A.
    Hutson, Kendall A.
    Pillsbury, Harold C.
    Fitzpatrick, Douglas C.
    EAR AND HEARING, 2019, 40 (04) : 833 - 848
  • [3] A Gerbil Model of Sloping Sensorineural Hearing Loss
    Suberman, Thomas A.
    Campbell, Adam P.
    Adunka, Oliver F.
    Buchman, Craig A.
    Roche, Joseph P.
    Fitzpatrick, Douglas C.
    OTOLOGY & NEUROTOLOGY, 2011, 32 (04) : 544 - 552
  • [4] Pneumolabyrinth, intracochlear and vestibular fluid loss after cochlear implantation
    Moteki, Hideaki
    Fujinaga, Yasunari
    Goto, Tetsuya
    Usami, Shin-ichi
    AURIS NASUS LARYNX, 2018, 45 (05) : 1116 - 1120
  • [5] Intracochlear schwannoma and cochlear implantation
    Kronenberg, J
    Horowitz, Z
    Hildesheimer, M
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1999, 108 (07) : 659 - 660
  • [6] Cochlear implantation in an animal model documents cochlear damage at the tip of the implant
    Cruz de Andrade, Jose Santos
    Baumhoff, Peter
    Mendonca Cruz, Oswaldo Laercio
    Lenarz, Thomas
    Kral, Andrej
    BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2022, 88 (04) : 546 - 555
  • [7] An animal model of cochlear implantation with an intracochlear fluid delivery system
    Nguyen, Yann
    Couloigner, Vincent
    Rudic, Milan
    Grayeli, Alexis Bozorg
    Ferrary, Evelyne
    Sterkers, Olivier
    ACTA OTO-LARYNGOLOGICA, 2009, 129 (11) : 1153 - 1159
  • [8] Cochlear implantation in children with postlingual hearing loss
    Ahmad, Faisal I.
    DeMason, Christine E.
    Teagle, Holly F. B.
    Henderson, Lillian
    Adunka, Oliver F.
    Buchman, Craig A.
    LARYNGOSCOPE, 2012, 122 (08) : 1852 - 1857
  • [9] Cochlear implantation in patients with prelingual hearing loss
    Hiraumi, Harukazu
    Yamamoto, Norio
    Sakamoto, Tatsunori
    Ito, Juichi
    ACTA OTO-LARYNGOLOGICA, 2010, 130 : 4 - 10
  • [10] Insertional depth-dependent intracochlear pressure changes in a model of cochlear implantation
    Mittmann, Marlene
    Ernst, Arneborg
    Mittmann, Philipp
    Todt, Ingo
    ACTA OTO-LARYNGOLOGICA, 2017, 137 (02) : 113 - 118