Accuracy of the Precision Saw versus the Sagittal Saw during total knee arthroplasty: A randomised clinical trial

被引:7
作者
Feczko, Peter Z. [1 ]
Fokkenrood, Hugo J. P. [2 ]
van Assen, Tijmen [3 ]
Deckers, Patrick [4 ]
Emans, Pieter J. [1 ]
Arts, Jacobus J. [1 ]
机构
[1] Maastricht Univ, Med Ctr, CAPHRI Res Sch, Dept Orthoped Surg, P Debyelaan 25, NL-6229 HX Maastricht, Netherlands
[2] Rijnstate Hosp, Dept Gen Surg, Arnhem, Netherlands
[3] Univ Utrecht, Med Ctr, Dept Sports Med, Utrecht, Netherlands
[4] Zuyderland Hosp, Dept Orthoped Surg, Heerlen, Netherlands
关键词
Orthopaedic saw; Total knee arthroplasty; Navigation; Accuracy; Surgery time; CUTTING ERRORS; NAVIGATION SYSTEM; DISTAL FEMUR; REPLACEMENT; ALIGNMENT;
D O I
10.1016/j.knee.2017.07.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The aim of this study was to compare the accuracy of the oscillating tip saw system (Precision Saw = PS) with the more conventional fully oscillating blade system (Sagittal Saw = SS) during computer-assisted total knee arthroplasty (CAS-TKA). Methods: A prospective, randomised, controlled trial included 58 consecutive patients who underwent primary CAS-TKA and were randomly assigned in the PS group or the SS group to compare the accuracy of both blades. The primary outcome was the difference between the intended cutting planes and the actual cutting planes in degrees () in two planes of both the femur and the tibia. The secondary outcome was total surgery time. Results: Tibia: In the W-plane no significant differences were registered for the mean absolute deviation (p = 0.28). The PS was more accurate in the AP-plane (p = 0.03). Femur: The PS showed significantly fewer mean absolute deviations in the W-plane (p = 0.03); however, the SS revealed better accuracy in the FE-plane (p = 0.04). The difference in the surgery time between the groups was not statistically significant (p = 0.45). Two outliers were measured using the SS, while seven outliers were detected using the PS. Conclusion: The Precision Saw is not proven to be overall more accurate than the Sagittal Saw. Significantly better accuracy was shown with the PS in the two cutting planes, with the exception of one cutting plane that favoured the SS. Greater number of outliers were found using the PS. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:1213 / 1220
页数:8
相关论文
共 19 条
  • [11] Otani T, 1993, J Arthroplasty, V8, P503
  • [12] Effect of Postoperative Mechanical Axis Alignment on the Fifteen-Year Survival of Modern, Cemented Total Knee Replacements
    Parratte, Sebastien
    Pagnano, Mark W.
    Trousdale, Robert T.
    Berry, Daniel J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (12) : 2143 - 2149
  • [13] Peters MP, 2016, ARTHROPLASTY
  • [14] Accuracy of a computer-assisted navigation system for total knee replacement
    Pitto, RP
    Graydon, AJ
    Bradley, L
    Malak, SF
    Walker, CG
    Anderson, IA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (05): : 601 - 605
  • [15] Bone cutting errors in total knee arthroplasty
    Plaskos, C
    Hodgson, AJ
    Inkpen, K
    McGraw, RW
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (06) : 698 - 705
  • [16] Sungkhun Pawaris, 2012, J Med Assoc Thai, V95 Suppl 10, pS87
  • [17] The Effect of a Sagittal Cutting Error of the Distal Femur on the Flexion-Extension Gap Difference in Total Knee Arthroplasty
    Tsukeoka, Tadashi
    Tsuneizumi, Yoshikazu
    Lee, Tae Hyun
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (07) : 1099 - 1102
  • [18] Demonstration of Saw Blade Accuracy and Excursion A Cadaveric Comparison Study of Blade Types Used in Total Knee Arthroplasty
    Wetzel, Robert J.
    Shah, Ritesh R.
    Puri, Lalit
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (06) : 985 - 987
  • [19] Cutting errors in total knee replacement: assessment by computer assisted surgery
    Yau, W. P.
    Chiu, K. Y.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (07) : 670 - 673