Accuracy of the Precision Saw versus the Sagittal Saw during total knee arthroplasty: A randomised clinical trial

被引:7
作者
Feczko, Peter Z. [1 ]
Fokkenrood, Hugo J. P. [2 ]
van Assen, Tijmen [3 ]
Deckers, Patrick [4 ]
Emans, Pieter J. [1 ]
Arts, Jacobus J. [1 ]
机构
[1] Maastricht Univ, Med Ctr, CAPHRI Res Sch, Dept Orthoped Surg, P Debyelaan 25, NL-6229 HX Maastricht, Netherlands
[2] Rijnstate Hosp, Dept Gen Surg, Arnhem, Netherlands
[3] Univ Utrecht, Med Ctr, Dept Sports Med, Utrecht, Netherlands
[4] Zuyderland Hosp, Dept Orthoped Surg, Heerlen, Netherlands
关键词
Orthopaedic saw; Total knee arthroplasty; Navigation; Accuracy; Surgery time; CUTTING ERRORS; NAVIGATION SYSTEM; DISTAL FEMUR; REPLACEMENT; ALIGNMENT;
D O I
10.1016/j.knee.2017.07.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The aim of this study was to compare the accuracy of the oscillating tip saw system (Precision Saw = PS) with the more conventional fully oscillating blade system (Sagittal Saw = SS) during computer-assisted total knee arthroplasty (CAS-TKA). Methods: A prospective, randomised, controlled trial included 58 consecutive patients who underwent primary CAS-TKA and were randomly assigned in the PS group or the SS group to compare the accuracy of both blades. The primary outcome was the difference between the intended cutting planes and the actual cutting planes in degrees () in two planes of both the femur and the tibia. The secondary outcome was total surgery time. Results: Tibia: In the W-plane no significant differences were registered for the mean absolute deviation (p = 0.28). The PS was more accurate in the AP-plane (p = 0.03). Femur: The PS showed significantly fewer mean absolute deviations in the W-plane (p = 0.03); however, the SS revealed better accuracy in the FE-plane (p = 0.04). The difference in the surgery time between the groups was not statistically significant (p = 0.45). Two outliers were measured using the SS, while seven outliers were detected using the PS. Conclusion: The Precision Saw is not proven to be overall more accurate than the Sagittal Saw. Significantly better accuracy was shown with the PS in the two cutting planes, with the exception of one cutting plane that favoured the SS. Greater number of outliers were found using the PS. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:1213 / 1220
页数:8
相关论文
共 19 条
  • [1] The accuracy of bone resections made during computer navigated total knee replacement. Do we resect what the computer plans we resect?
    Biant, Leela C.
    Yeoh, Kwan
    Walker, Peter M.
    Bruce, Warwick J. M.
    Walsh, William R.
    [J]. KNEE, 2008, 15 (03) : 238 - 241
  • [2] Daluga D, 1991, J Arthroplasty, V6, P119, DOI 10.1016/S0883-5403(11)80006-9
  • [3] Coronal Alignment in Total Knee Arthroplasty Just How Important is it?
    Fang, David M.
    Ritter, Merrill A.
    Davis, Kenneth E.
    [J]. JOURNAL OF ARTHROPLASTY, 2009, 24 (06) : 39 - 43
  • [4] Metal debris from bony resection in knee arthroplasty - is it an issue? Experiments in pigs
    Gotterson, PR
    Nusem, I
    Pearcy, MJ
    Crawford, RW
    [J]. ACTA ORTHOPAEDICA, 2005, 76 (04) : 475 - 480
  • [5] Execution accuracy of bone resection and implant fixation in computer assisted minimally invasive total knee arthroplasty
    Kim, Tae Kyun
    Chang, Chong Bum
    Kang, Yeon Gwi
    Chung, Byung June
    Cho, Hyung Joon
    Seong, Sang Cheol
    [J]. KNEE, 2010, 17 (01) : 23 - 28
  • [6] Improved tibial cutting accuracy in knee arthroplasty
    Macdonald, W
    Styf, J
    Carlsson, LV
    Jacobsson, CM
    [J]. MEDICAL ENGINEERING & PHYSICS, 2004, 26 (09) : 807 - 812
  • [7] Varus-valgus balance and range of movement after total knee arthroplasty
    Matsuda, Y
    Ishii, Y
    Noguchi, H
    Ishii, R
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (06): : 804 - 808
  • [8] Prosthetic alignment and sizing in computer-assisted total knee arthroplasty
    Matsumoto, T
    Tsumura, N
    Kurosaka, M
    Muratsu, H
    Kuroda, R
    Ishimoto, K
    Tsujimoto, K
    Shiba, R
    Yoshiya, S
    [J]. INTERNATIONAL ORTHOPAEDICS, 2004, 28 (05) : 282 - 285
  • [9] Cutting Error of the Distal Femur in Total Knee Arthroplasty by Use of a Navigation System
    Nakahara, Hiroyuki
    Matsuda, Shuichi
    Moro-oka, Taka-aki
    Okazaki, Ken
    Tashiro, Yasutaka
    Iwamoto, Yukihide
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (06) : 1119 - 1122
  • [10] Ohmori T., 2015, OPEN J ORTHOP, V05, P297, DOI [10.4236/ojo.2015.510040, DOI 10.4236/OJO.2015.510040]