Immuno-Enriched Microspheres - Magnetic Blade Spray-Tandem Mass Spectrometry for Domoic Acid in Mussels

被引:16
作者
Geballa-Koukoula, Ariadni [1 ]
Gerssen, Arjen [1 ]
Blokland, Marco H. [1 ]
Elliott, Christopher T. [2 ]
Pawliszyn, Janusz [3 ]
Nielen, Michel W. F. [1 ,4 ]
机构
[1] Wageningen Univ & Res, Wageningen Food Safety Res, NL-6700 AE Wageningen, Netherlands
[2] Queens Univ Belfast, ASSET Technol Ctr, Sch Biol Sci, Inst Global Food Secur, Belfast BT9 5DL, Antrim, North Ireland
[3] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[4] Wageningen Univ, Lab Organ Chem, NL-6708 WE Wageningen, Netherlands
基金
欧盟地平线“2020”;
关键词
SURFACE-PLASMON RESONANCE; CHEMICAL CONTAMINANTS; FOOD; ANALYTES;
D O I
10.1021/acs.analchem.1c03816
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Paramagnetic microspheres can be used in planar array fluorescence immunoassays for single or multiplex screening of food contaminants. However, no confirmation of the molecular identity is obtained. Coated blade spray (CBS) is a direct ionization mass spectrometry (MS) technique, and when combined with triple quadrupole MS/MS, it allows for rapid confirmation of food contaminants. The lack of chromatography in CBS, though, compromises the specificity of the measurement for unequivocal identification of contaminants, based on the European Union (EU) regulation. Therefore, a rapid and easy-to-use immuno-magnetic blade spray (iMBS) method was developed in which immuno-enriched paramagnetic microspheres replace the coating of CBS. The iMBS-MS/MS method was fully optimized, validated in-house following the EU 2021/808 regulation, and benchmarked against a commercial lateral flow immunoassay (LFIA) for on-site screening of DA. The applicability of iMBS-MS/MS was further demonstrated by analyzing incurred mussel samples. The combination of immunorecognition and MS/MS detection in iMBS-MS/MS enhances the measurement's selectivity, which is demonstrated by the rapid differentiation between the marine toxin domoic acid (DA) and its structural analog kainic acid (KA), which cannot be achieved with the LFIA alone. Interestingly, this first-ever reported iMBS-MS/MS method is generic and can be adapted to include any other immuno-captured food contaminant, provided that monoclonal antibodies are available, thus offering a complementary confirmatory analysis approach to multiplex immunoassay screening methods. Moreover, thanks to its speed of analysis, iMBS-MS/MS can bridge the logistics gap between future large-scale on-site testings using LFIAs and classical time-consuming confirmatory MS analysis performed in official control laboratories.
引用
收藏
页码:15736 / 15743
页数:8
相关论文
共 31 条
[1]  
Beneito-Cambra M, 2020, ANAL METHODS-UK, V12, P4831, DOI [10.1039/d0ay01474e, 10.1039/D0AY01474E]
[2]   The (Un)Certainty of Selectivity in Liquid Chromatography Tandem Mass Spectrometry [J].
Berendsen, Bjorn J. A. ;
Stolker, Linda A. M. ;
Nielen, Michel W. F. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (01) :154-163
[3]   Potential of Recent Ambient Ionization Techniques for Future Food Contaminant Analysis Using (Trans)Portable Mass Spectrometry [J].
Blokland, Marco H. ;
Gerssen, Arjen ;
Zoontjes, Paul W. ;
Pawliszyn, Janusz ;
Nielen, Michel W. F. .
FOOD ANALYTICAL METHODS, 2020, 13 (03) :706-717
[4]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[5]  
Dunbar S A., 2013, The Immunoassay Handbook, P157
[6]   Multidetection of Paralytic, Diarrheic, and Amnesic Shellfish Toxins by an Inhibition Immunoassay Using a Microsphere-Flow Cytometry System [J].
Fraga, Maria ;
Vilarino, Natalia ;
Carmen Louzao, M. ;
Rodriguez, Paula ;
Campbell, Katrina ;
Elliott, Christopher T. ;
Botana, Luis M. .
ANALYTICAL CHEMISTRY, 2013, 85 (16) :7794-7802
[7]   From Smartphone Lateral Flow Immunoassay Screening to Direct MS Analysis: Development and Validation of a Semi-Quantitative Direct Analysis in Real-Time Mass Spectrometric (DART-MS) Approach to the Analysis of Deoxynivalenol [J].
Geballa-Koukoula, Ariadni ;
Gerssen, Arjen ;
Nielen, Michel W. F. .
SENSORS, 2021, 21 (05) :1-17
[8]   Direct analysis of lateral flow immunoassays for deoxynivalenol using electrospray ionization mass spectrometry [J].
Geballa-Koukoula, Ariadni ;
Gerssen, Arjen ;
Nielen, Michel W. F. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (27) :7547-7558
[9]   Development of Coated Blade Spray Ionization Mass Spectrometry for the Quantitation of Target Analytes Present in Complex Matrices [J].
Gomez-Rios, German Augusto ;
Pawliszyn, Janusz .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2014, 53 (52) :14503-14507
[10]   The genesis and evolution of bead-based multiplexing [J].
Graham, Hilary ;
Chandler, Don J. ;
Dunbar, Sherry A. .
METHODS, 2019, 158 :2-11