Computational Study of Haemodynamic Effects of Entry- and Exit-Tear Coverage in a DeBakey Type III Aortic Dissection: Technical Report

被引:69
作者
Karmonik, C. [1 ,2 ]
Bismuth, J. [1 ]
Shah, D. J. [1 ]
Davies, M. G. [1 ]
Purdy, D. [3 ]
Lumsden, A. B. [1 ]
机构
[1] Methodist Hosp, Methodist DeBakey Heart & Vasc Ctr, Houston, TX 77030 USA
[2] Methodist Hosp, Neurol Inst, Dept Neurosurg, Houston, TX 77030 USA
[3] Siemens Healthcare, Malvern, PA USA
关键词
Aortic dissection; Magnetic resonance imaging; Aortic disease; Computational fluid dynamics; FALSE LUMEN; BLOOD-FLOW; SIZE;
D O I
10.1016/j.ejvs.2011.04.008
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: Outcome prediction in DeBakey Type III aortic dissections (ADs) remains challenging. Large variations in AD morphology, physiology and treatment exist. Here, we investigate if computational fluid dynamics (CFD) can provide an initial understanding of pressure changes in an AD computational model when covering entry and exit tears and removing the intra-arterial septum (IS). Design: A computational mesh was constructed from magnetic resonance images from one patient (one entrance and one exit tear) and CFD simulations performed (scenario #1). Additional meshes were derived by virtually (1) covering the exit tear (false lumen (FL) thrombus progression) (scenario #2), (2) covering the entrance tear (thoracic endovascular treatment, TEVAR) (scenario #3) and (3) completely removing the IS (fenestration) (scenario #4). Changes in flow patterns and pressures were quantified relative to the initial mesh. Results: Systolic pressures increased for #2 (300 Pa increase) with largest inter-luminal differences distally (2500 Pa). In #3, false lumen pressure decreased essentially to zero. In #4, systolic pressure in combined lumen reduced from 2400 to 800 Pa. Conclusions: CFD results from computational models of a DeBakey type III AD representing separate coverage of entrance and exit tears correlated with clinical experience. The reported results present a preliminary look at a complex clinical problem. (C) 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:172 / 177
页数:6
相关论文
共 16 条
[1]  
Cebral JR, 2005, AM J NEURORADIOL, V26, P2550
[2]   The role of false lumen size in prediction of in-hospital complications after acute type B aortic dissection [J].
Chang, Chih-Ping ;
Liu, Juhn-Cherng ;
Liou, Ying-Ming ;
Chang, Shih-Sheng ;
Chen, Jan-Yow .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (14) :1170-1176
[3]  
CHENG Z, J BIOMECH ENG, V132
[4]  
Eggebrecht H, 2005, EUR HEART J, V26, P489, DOI 10.1093/eurheartj/ehi099
[5]  
Hinchliffe RJ, 2008, J CARDIOVASC SURG, V49, P449
[6]  
KARMONIK C, C P IEEE ENG MED BIO, V1, P3138
[7]  
Karmonik Christof, 2008, Technol Health Care, V16, P343
[8]   Blood flow and structure interactions in a stented abdominal aortic aneurysm model [J].
Li, ZH ;
Kleinstreuer, C .
MEDICAL ENGINEERING & PHYSICS, 2005, 27 (05) :369-382
[9]   Three-Dimensional Flow Characteristics in Aortic Coarctation and Poststenotic Dilatation [J].
Markl, Michael ;
Arnold, Raoul ;
Hirtler, Daniel ;
von zur Muhlen, Constantin ;
Harloff, Andreas ;
Langer, Mathias ;
Hennig, Juergen ;
Frydrychowicz, Alex .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (05) :776-778
[10]   Aortic fenestration for acute or chronic aortic dissection: An uncommon but effective procedure [J].
Panneton, JM ;
Teh, SH ;
Cherry, KJ ;
Hofer, JM ;
Gloviczki, P ;
Andrews, JC ;
Bower, TC ;
Pairolero, PC ;
Hallett, JW .
JOURNAL OF VASCULAR SURGERY, 2000, 32 (04) :711-720